Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 90
Filter
1.
Neuroradiol J ; : 19714009241242645, 2024 Mar 25.
Article in English | MEDLINE | ID: mdl-38525966

ABSTRACT

BACKGROUND AND PURPOSE: Spontaneous intracranial hypotension (SIH) is caused by spinal cerebrospinal fluid (CSF) leaks. This study assessed whether the certainty and/or multifocality of CSF leaks is associated with the severity of intracranial sequelae of SIH. MATERIALS AND METHODS: A retrospective review was completed of patients with suspected SIH that underwent digital subtraction myelogram (DSM) preceded by brain MRI. DSMs were evaluated for the presence or absence of a CSF leak, categorized both as positive/negative/indeterminate and single versus multifocal. Brain MRIs were assessed for intracranial sequelae of SIH based on two probabilistic scoring systems (Dobrocky and Mayo methods). For each system, both an absolute "numerical" score (based on tabulation of findings) and "categorized" score (classification of probability) were tabulated. RESULTS: 174 patients were included; 113 (64.9%) were female, average age 52.0 ± 14.3 years. One or more definite leaks were noted in 76 (43.7%) patients; an indeterminate leak was noted in 22 (12.6%) patients. 16 (16.3%) had multiple leaks. There was no significant difference in the severity of intracranial findings between patients with a single versus multiple leaks (p values ranged from .36 to .70 using categorized scores and 0.22-0.99 for numerical scores). Definite leaks were more likely to have both higher categorized intracranial scores (Mayo p = .0008, Dobrocky p = .006) and numerical scores (p = .0002 for Mayo and p = .006 for Dobrocky). CONCLUSIONS: Certainty of a CSF leak on diagnostic imaging is associated with severity of intracranial sequelae of SIH, with definite leaks having significantly more intracranial findings than indeterminate leaks. Multifocal leaks do not cause greater intracranial abnormalities.

2.
Br J Radiol ; 97(1157): 894-901, 2024 May 07.
Article in English | MEDLINE | ID: mdl-38460543

ABSTRACT

Photon-counting CT (PCCT) uses a novel X-ray detection mechanism that confers many advantages over that used in traditional energy integrating CT. As PCCT becomes more available, it is important to thoroughly understand its benefits and highest yield areas for improvements in diagnosis of various diseases. Based on our early experience, we have identified several areas of neurovascular imaging in which PCCT shows promise. Here, we describe the benefits in diagnosing arterial and venous diseases in the head, neck, and spine. Specifically, we focus on applications in head and neck CT angiography (CTA), spinal CT angiography, and CT myelography for detection of CSF-venous fistulas. Each of these applications highlights the technological advantages of PCCT in neurovascular imaging. Further understanding of these applications will not only benefit institutions incorporating PCCT into their practices but will also help guide future directions for implementation of PCCT for diagnosing other pathologies in neuroimaging.


Subject(s)
Computed Tomography Angiography , Photons , Tomography, X-Ray Computed , Humans , Computed Tomography Angiography/methods , Tomography, X-Ray Computed/methods , Myelography/methods , Cerebrovascular Disorders/diagnostic imaging
4.
Interv Neuroradiol ; : 15910199231221857, 2024 Jan 05.
Article in English | MEDLINE | ID: mdl-38179603

ABSTRACT

Epidural steroid injections are commonly performed using fluoroscopic or CT guidance. With both modalities, the injection of contrast material is necessary before steroid administration to ensure adequate epidural flow and exclude non-epidural flow. While fluoroscopic guidance is conventional, CT is utilized at some centers and can be particularly helpful in the setting of challenging or postoperative anatomy. It is important for proceduralists to be adept at evaluating contrast media flow patterns under both modalities. The goal of this review article is to describe and provide examples of epidural and non-epidural flow patterns on both conventional fluoroscopy and CT. Specific non-epidural patterns discussed include intrathecal flow, intradural/subdural flow, vascular uptake, flow into the retrodural space of Okada, inadvertent facet joint flow, and intradiscal flow.

5.
Clin Neuroradiol ; 34(1): 251-255, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38055090

ABSTRACT

BACKGROUND: Superior semicircular canal dehiscence (SSCD), an osseous defect overlying the SSC, is associated with a constellation of audiovestibular symptoms. This study sought to compare conventional energy-integrated detector (EID) computed tomography (CT) to photon-counting detector (PCD)-CT in the detection of SSCD. MATERIAL AND METHODS: Included patients were prospectively recruited to undergo a temporal bone CT on both EID-CT and PCD-CT scanners. Two blinded neuroradiologists reviewed both sets of images for 1) the presence or absence of SSCD (graded as present, absent, or indeterminate), and 2) the width of the bone overlying the SSC (if present). Any discrepancies in the presence or absence of SSCD were agreed upon by consensus. RESULTS: In the study 31 patients were evaluated, for a total of 60 individual temporal bones (2 were excluded). Regarding SSCD presence or absence, there was substantial agreement between EID-CT and PCD-CT (k = 0.76; 95% confidence interval, CI 0.54-0.97); however, SSCD was present in only 9 (15.0%) temporal bones on PCD-CT, while EID-CT examinations were interpreted as being positive in 14 (23.3%) temporal bones. This yielded a false positive rate of 8.3% on EID-CT. The bone overlying the SSC was thinner on EID-CT images (0.66 mm; SD = 0.64) than on PCD-CT images (0.72 mm; SD = 0.66) (p < 0.001). CONCLUSION: The EID-CT examinations tend to overcall the presence of SSCD compared to PCD-CT and also underestimate the thickness of bone overlying the SSC.


Subject(s)
Semicircular Canal Dehiscence , Humans , Tomography, X-Ray Computed/methods , Temporal Bone/diagnostic imaging , Phantoms, Imaging
6.
Neuroradiol J ; 37(1): 84-91, 2024 Feb.
Article in English | MEDLINE | ID: mdl-37933451

ABSTRACT

Cauda Equina Neuroendocrine Tumors (CE-NET), previously referred to as paragangliomas are a rare subset of spinal tumors, with limited data on imaging. Herein, we present a retrospective review of clinical and imaging findings of CE-NETs in ten patients who were evaluated at our institution over the past two decades. All patients had well-defined intradural lesions in the lumbar spine which demonstrated slow growth. A review of imaging findings revealed the presence of an eccentric vascular pedicle along the dorsal aspect of the tumor in 8 of the 10 patients (eccentric vessel sign), a distinctive finding that has not previously been reported with this tumor and may help improve the accuracy of imaging-based diagnosis. In all cases, a gross-total resection was performed, with resolution of symptoms in most of the cases.


Subject(s)
Cauda Equina , Central Nervous System Neoplasms , Neuroendocrine Tumors , Paraganglioma , Spinal Neoplasms , Humans , Spinal Neoplasms/pathology , Neuroendocrine Tumors/diagnostic imaging , Neuroendocrine Tumors/surgery , Neuroendocrine Tumors/pathology , Cauda Equina/diagnostic imaging , Cauda Equina/surgery , Paraganglioma/diagnostic imaging , Paraganglioma/surgery , Central Nervous System Neoplasms/pathology , Magnetic Resonance Imaging
7.
AJNR Am J Neuroradiol ; 44(12): 1445-1450, 2023 12 11.
Article in English | MEDLINE | ID: mdl-37945523

ABSTRACT

BACKGROUND AND PURPOSE: CSF-venous fistulas are a common cause of spontaneous intracranial hypotension. Lateral decubitus digital subtraction myelography and CT myelography are the diagnostic imaging standards to identify these fistulas. Photon-counting CT myelography has technological advantages that might improve CSF-venous fistula detection, though no large studies have yet assessed its diagnostic performance. We sought to determine the diagnostic yield of photon-counting detector CT myelography for detection of CSF-venous fistulas in patients with spontaneous intracranial hypotension. MATERIALS AND METHODS: We retrospectively searched our database for all decubitus photon-counting detector CT myelograms performed at our institution since the introduction of the technique in our practice. Per our institutional workflow, all patients had prior contrast-enhanced brain MR imaging and spine MR imaging showing no extradural CSF. Two neuroradiologists reviewed preprocedural brain MRIs, assessing previously described findings of intracranial hypotension (Bern score). Additionally, 2 different neuroradiologists assessed each myelogram for a definitive or equivocal CSF-venous fistula. The yield of photon-counting detector CT myelography was calculated and stratified by the Bern score using low-, intermediate-, and high-probability tiers. RESULTS: Fifty-seven consecutive photon-counting detector CT myelograms in 57 patients were included. A single CSF-venous fistula was definitively present in 38/57 patients. After we stratified by the Bern score, a definitive fistula was seen in 56.0%, 73.3%, and 76.5% of patients with low-, intermediate-, and high-probability brain MR imaging, respectively. CONCLUSIONS: Decubitus photon-counting detector CT myelography has an excellent diagnostic performance for the detection of CSF-venous fistulas. The yield for patients with intermediate- and high-probability Bern scores is at least as high as previously reported yields of decubitus digital subtraction myelography and CT myelography using energy-integrating detector scanners. The yield for patients with low-probability Bern scores appears to be greater compared with other modalities. Due to the retrospective nature of this study, future prospective work will be needed to compare the sensitivity of photon-counting detector CT myelography with other modalities.


Subject(s)
Fistula , Intracranial Hypotension , Humans , Intracranial Hypotension/etiology , Cerebrospinal Fluid Leak/complications , Retrospective Studies , Myelography/methods , Tomography, X-Ray Computed/methods , Fistula/complications
8.
Interv Neuroradiol ; : 15910199231175198, 2023 Jul 03.
Article in English | MEDLINE | ID: mdl-37401156

ABSTRACT

BACKGROUND AND PURPOSE: Recent introduction of photon counting detector (PCD) computed tomography (CT) scanners into clinical practice further improve CT angiography (CTA) depiction of orbital arterial vasculature compared to conventional energy integrating detector (EID) CT scanners. PCD-CTA of the orbit can provide a detailed arterial roadmap of the orbit which can de diagnostic on its own or serve as a helpful planning adjunct for both diagnostic and therapeutic catheter-based angiography of the orbit. METHODS: For this review, EID and PCD-CT imaging was obtained in 28 volunteers. The volume CT dose index was closely matched. A dual-energy scanning protocol was used on EID-CT. An ultra-high-resolution (UHR) scan mode was used on PCD-CT. Images were reconstructed at 0.6 mm slice thickness using a closely matched medium-sharp standard resolution (SR) kernel. High-resolution (HR) images with the sharpest quantitative kernel were also reconstructed on PCD-CT at the thinnest slice thickness of 0.2 mm. A denoising algorithm was applied to the HR image series. RESULTS: The imaging description of the orbital vascular anatomy presented in this work was derived from these patients' PCD-CTA images in combination with review of the literature. We found that orbital arterial anatomy is much better depicted with PCD-CTA, and this work can serve primarily as an imaging atlas of the normal orbital vascular anatomy. CONCLUSION: With recent advances in technology, arterial anatomy of the orbit is much better depicted with PCD-CTA as opposed to EID-CTA. Current orbital PCD-CTA technology approaches the necessary resolution threshold for reliable evaluation of central retinal artery occlusion.

9.
Neuroradiol J ; 36(5): 593-600, 2023 Oct.
Article in English | MEDLINE | ID: mdl-37128777

ABSTRACT

INTRODUCTION: Spontaneous intracranial hypotension (SIH) caused by a spinal cerebrospinal fluid (CSF) leak classically presents with orthostatic headache. Digital subtraction myelography (DSM) has a well-established diagnostic yield in the absence of extradural spinal collection. At our institution, DSM is followed by lateral decubitus CT myelogram (LDCTM) in the same decubitus position to increase diagnostic yield of the combined study. We evaluated the incremental diagnostic yield of LDCTM following negative DSM and reviewed patient outcomes. METHODS: Retrospective review of consecutive DSMs with subsequent LDCTM from April 2019 to March 2021 was performed. Combined reports were reviewed, and studies with positive DSMs were excluded. Of the exams with negative DSM, only studies with LDCTM reports identifying potential leak site were included. Interventions and follow-up clinical notes were reviewed to assess symptoms improvement following treatment. RESULTS: Of the 83 patients with negative DSMs, 11 (13.2%) had positive leak findings on LDCTMs, and 21 (25.3%) were equivocal. Of 11 positive LDCTMs, 6 leaks were nerve sheath tears (NSTs) and 5 were CSF-venous fistulas (CVFs). 10/11 (90.9%) had intervention and follow-up, with 9/10 (90%) having positive clinical outcome. Of the 21 equivocal LDCTM patients (19 CVFs and 2 NSTs), 15 (71.4%) had interventions and follow-up, with 3/15 (20.0%) with positive clinical outcomes. CONCLUSION: LDCTM following negative DSM has an incremental diagnostic yield up to 38.6%, with up to 14.5% of positive patient outcomes following treatment. LDCTM should be considered after DSM to maximize diagnostic yield of the combined exam.

11.
Eur Radiol ; 33(8): 5309-5320, 2023 Aug.
Article in English | MEDLINE | ID: mdl-37020069

ABSTRACT

The X-ray detector is a fundamental component of a CT system that determines the image quality and dose efficiency. Until the approval of the first clinical photon-counting-detector (PCD) system in 2021, all clinical CT scanners used scintillating detectors, which do not capture information about individual photons in the two-step detection process. In contrast, PCDs use a one-step process whereby X-ray energy is converted directly into an electrical signal. This preserves information about individual photons such that the numbers of X-ray in different energy ranges can be counted. Primary advantages of PCDs include the absence of electronic noise, improved radiation dose efficiency, increased iodine signal and the ability to use lower doses of iodinated contrast material, and better spatial resolution. PCDs with more than one energy threshold can sort the detected photons into two or more energy bins, making energy-resolved information available for all acquisitions. This allows for material classification or quantitation tasks to be performed in conjunction with high spatial resolution, and in the case of dual-source CT, high pitch, or high temporal resolution acquisitions. Some of the most promising applications of PCD-CT involve imaging of anatomy where exquisite spatial resolution adds clinical value. These include imaging of the inner ear, bones, small blood vessels, heart, and lung. This review describes the clinical benefits observed to date and future directions for this technical advance in CT imaging. KEY POINTS: • Beneficial characteristics of photon-counting detectors include the absence of electronic noise, increased iodine signal-to-noise ratio, improved spatial resolution, and full-time multi-energy imaging. • Promising applications of PCD-CT involve imaging of anatomy where exquisite spatial resolution adds clinical value and applications requiring multi-energy data simultaneous with high spatial and/or temporal resolution. • Future applications of PCD-CT technology may include extremely high spatial resolution tasks, such as the detection of breast micro-calcifications, and quantitative imaging of native tissue types and novel contrast agents.


Subject(s)
Iodine Compounds , Iodine , Humans , Tomography, X-Ray Computed/methods , Tomography Scanners, X-Ray Computed , Contrast Media , Photons , Phantoms, Imaging
12.
Radiographics ; 43(5): e220158, 2023 05.
Article in English | MEDLINE | ID: mdl-37022956

ABSTRACT

Photon-counting detector (PCD) CT is an emerging technology that has led to continued innovation and progress in diagnostic imaging after it was approved by the U.S. Food and Drug Administration for clinical use in September 2021. Conventional energy-integrating detector (EID) CT measures the total energy of x-rays by converting photons to visible light and subsequently using photodiodes to convert visible light to digital signals. In comparison, PCD CT directly records x-ray photons as electric signals, without intermediate conversion to visible light. The benefits of PCD CT systems include improved spatial resolution due to smaller detector pixels, higher iodine image contrast, increased geometric dose efficiency to allow high-resolution imaging, reduced radiation dose for all body parts, multienergy imaging capabilities, and reduced artifacts. To recognize these benefits, diagnostic applications of PCD CT in musculoskeletal, thoracic, neuroradiologic, cardiovascular, and abdominal imaging must be optimized and adapted for specific diagnostic tasks. The diagnostic benefits and clinical applications resulting from PCD CT in early studies have allowed improved visualization of key anatomic structures and radiologist confidence for some diagnostic tasks, which will continue as PCD CT evolves and clinical use and applications grow. ©RSNA, 2023 Quiz questions for this article are available in the supplemental material. See the invited commentary by Ananthakrishnan in this issue.


Subject(s)
Iodine , Tomography, X-Ray Computed , Humans , Phantoms, Imaging , Tomography, X-Ray Computed/methods , Radiographic Image Enhancement/methods , Photons
13.
Spine J ; 23(6): 868-876, 2023 06.
Article in English | MEDLINE | ID: mdl-36754150

ABSTRACT

BACKGROUND CONTEXT: Native vertebral osteomyelitis (NVO) is a severe infection with an increasing incidence globally. Although there is no widely agreed upon reference standard for diagnosis of the disease, imaging plays a crucial role. Magnetic resonance imaging (MRI) is currently the imaging modality of choice. In recent years, advances in imaging have allowed for a larger role for alternative imaging techniques in the setting of NVO. PURPOSE: Our aim was to evaluate the diagnostic accuracy of MRI, PET/CT, and nuclear imaging, namely 67Gallium and 99mTechnetium scintigraphy, in the diagnosis of pyogenic NVO. STUDY DESIGN/SETTING: We conducted a systematic review of five medical databases and included all studies from 1970 to September 2021 that compared imaging techniques and provided sufficient data for diagnostic test accuracy meta-analysis. METHODS: Abstract screening, full text review, and data extraction were done by a pair of independent reviewers. Nonnative and nonpyogenic patients were excluded. A bivariate random effect model was used for meta-analysis. RESULTS: Twenty studies were included in the meta-analysis, encompassing a total of 1,123 imaging studies. The meta-analysis sensitivity and specificity of MRI were 90% and 72% respectively; those of PET/CT were 93% and 80%; those of 67Ga were 95% and 88%; those of 99mTc were 86% and 39%; and the sensitivity and specificity of combined Ga and Tc were 91% and 92% respectively in the setting of suspected NVO. CONCLUSIONS: 67Ga has the highest sensitivity for NVO, and its specificity is augmented when combined with 99mTc. MRI and PET/CT are both highly sensitive modalities, although the specificity of PET/CT is slightly better. MRI remains an appropriate initial test depending on the availability of other modalities.


Subject(s)
Magnetic Resonance Imaging , Osteomyelitis , Positron Emission Tomography Computed Tomography , Humans , Osteomyelitis/diagnostic imaging , Radionuclide Imaging , Sensitivity and Specificity
14.
Pain Med ; 24(7): 782-786, 2023 07 05.
Article in English | MEDLINE | ID: mdl-36852864

ABSTRACT

OBJECTIVE: To describe the technique, safety profile, and outcome of computed tomography (CT)-guided atlanto-axial lateral articulation injections performed at our institution. METHODS: Consecutive cases of all CT-guided atlanto-axial injections performed from January 2017 to April 2022 at our institution were searched in the electronic medical records. Patient charts were reviewed for demographics, characterization of pain, potential altered anatomy, pain level before and immediately after the procedure, procedure technique, complications, and follow-up outcomes, if available. RESULTS: Forty-five injections in 40 different patients were included. The average age was 67.4 years, and 28 (70%) of the patients were female. Of the 45 injections, 43 (96%) were technically successful. The average change in pain score (0-10) from immediately before to immediately after the injection was -3.36 (SD = 2.87, range = -8 to +3). Of all injections, 14 (31%) had a postprocedural pain score of zero. In 2 cases (4%), patients reported an increase in pain score immediately after the injection. In 3 cases (7%), transient non-vertebral artery vascular uptake of contrast was documented during the procedure, which could be cleared with needle repositioning. There were no complications. CONCLUSION: CT-guided atlanto-axial lateral articulation injection is a safe procedure with a high technical success rate. It allows for direct visualization of vital structures and provides an alternative option to the traditional fluoroscopic guidance, especially in cases of prior technically unsuccessful fluoroscopically guided injection or altered anatomy.


Subject(s)
Atlanto-Axial Joint , Pain , Humans , Female , Aged , Male , Atlanto-Axial Joint/diagnostic imaging , Injections , Tomography, X-Ray Computed , Fluoroscopy
15.
AJNR Am J Neuroradiol ; 45(1): 96-99, 2023 Dec 29.
Article in English | MEDLINE | ID: mdl-38164538

ABSTRACT

Photon-counting detector CT myelography is a recently described technique that has several advantages for the detection of CSF-venous fistulas, one of which is improved spatial resolution. To maximally leverage the high spatial resolution of photon-counting detector CT, a sharp kernel and a thin section reconstruction are needed. Sharp kernels and thin slices often result in increased noise, degrading image quality. Here, we describe a novel deep-learning-based algorithm used to denoise photon-counting detector CT myelographic images, allowing the sharpest and thinnest quantitative reconstruction available on the scanner to be used to enhance diagnostic image quality. Currently, the algorithm requires 4-6 hours to create diagnostic, denoised images. This algorithm has the potential to increase the sensitivity of photon-counting detector CT myelography for detecting CSF-venous fistulas, and the technique may be valuable for institutions attempting to optimize photon-counting detector CT myelography imaging protocols.


Subject(s)
Fistula , Photons , Humans , Phantoms, Imaging , Tomography, X-Ray Computed/methods , Neural Networks, Computer
16.
Open Forum Infect Dis ; 9(12): ofac616, 2022 Dec.
Article in English | MEDLINE | ID: mdl-36570966

ABSTRACT

Background: Image-guided biopsies in patients with suspected native vertebral osteomyelitis (NVO) are recommended to establish the microbiological diagnosis and guide antibiotic therapy. Despite recent advances, the microbiological yield of this procedure remains between 48% and 52%. A better understanding of factors associated with this low yield may lead to improved microbiological diagnosis. Methods: We retrospectively identified patients with suspected NVO undergoing image-guided biopsies from January 2011 to June 2021 at our institution. Two hundred nine patients undergoing 248 percutaneous biopsies were included. Demographic data, biopsy and microbiologic techniques, clinical characteristics, and antibiotic use were collected. Multivariable logistic regression analysis was conducted to determine factors associated with microbiological yield. Results: A total of 110 of 209 (52.6%) initial image-guided biopsies revealed positive microbiological results. This number increased to 121 of 209 (57.9%) when repeat image-guided biopsies were included. In multivariable analysis, aspiration of fluid was associated with a 3-fold increased odds of yielding a positive result (odds ratio [OR], 3.13; 95% confidence interval [CI], 1.39-7.04; P = .006), whereas prior antibiotic use was associated with a 3-fold decreased yield (OR, 0.32; 95% CI, .16-.65; P = .002). A univariate subgroup analysis revealed a significant association between the length of the antibiotic-free period and microbiological yield, with the lowest rates of pathogen detection at 0-3 days and higher rates as duration increased (P = .017). Conclusions: Prior antibiotic use in patients with suspected NVO was associated with a decrease in the microbiological yield of image-guided biopsies. An antibiotic-free period of at least 4 days is suggested to maximize yield. Successful fluid aspiration during the procedure also increases microbiological yield.

17.
Phys Med Biol ; 67(17)2022 09 02.
Article in English | MEDLINE | ID: mdl-35944556

ABSTRACT

Objective.To develop a convolutional neural network (CNN) noise reduction technique for ultra-high-resolution photon-counting detector computed tomography (UHR-PCD-CT) that can be efficiently implemented using only clinically available reconstructed images. The developed technique was demonstrated for skeletal survey, lung screening, and head angiography (CTA).Approach. There were 39 participants enrolled in this study, each received a UHR-PCD and an energy integrating detector (EID) CT scan. The developed CNN noise reduction technique uses image-based noise insertion and UHR-PCD-CT images to train a U-Net via supervised learning. For each application, 13 patient scans were reconstructed using filtered back projection (FBP) and iterative reconstruction (IR) and allocated into training, validation, and testing datasets (9:1:3). The subtraction of FBP and IR images resulted in approximately noise-only images. The 5-slice average of IR produced a thick reference image. The CNN training input consisted of thick reference images with reinsertion of spatially decoupled noise-only images. The training target consisted of the corresponding thick reference images without noise insertion. Performance was evaluated based on difference images, line profiles, noise measurements, nonlinear perturbation assessment, and radiologist visual assessment. UHR-PCD-CT images were compared with EID images (clinical standard).Main results.Up to 89% noise reduction was achieved using the proposed CNN. Nonlinear perturbation assessment indicated reasonable retention of 1 mm radius and 1000 HU contrast signals (>80% for skeletal survey and head CTA, >50% for lung screening). A contour plot indicated reduced retention for small-radius and low contrast perturbations. Radiologists preferred CNN over IR for UHR-PCD-CT noise reduction. Additionally, UHR-PCD-CT with CNN was preferred over standard resolution EID-CT images.Significance.CT images reconstructed with very sharp kernels and/or thin sections suffer from increased image noise. Deep learning noise reduction can be used to offset noise level and increase utility of UHR-PCD-CT images.


Subject(s)
Photons , Radiographic Image Enhancement , Humans , Neural Networks, Computer , Phantoms, Imaging , Radiographic Image Enhancement/methods , Tomography, X-Ray Computed/methods
18.
Neuroradiology ; 64(9): 1719-1728, 2022 Sep.
Article in English | MEDLINE | ID: mdl-35701631

ABSTRACT

PURPOSE: Following spinal instrumentation and fusion, differentiating between successful arthrodesis and pseudoarthrosis on imaging can be challenging. Interpretation of such examinations requires understanding both the expected evolution of postoperative findings and the subtle indicators of pseudoarthrosis across multiple imaging modalities. Due to this level of intricacy, many clinicians lack familiarity with the subject beyond the more rudimentary concepts. METHODS: This review provides an in-depth overview of the imaging of the post-operative spine, with particular emphasis on differentiating between pseudoarthrosis and arthrodesis. RESULTS: A comprehensive overview of imaging of the post-operative spine is given, including the most common imaging modalities utilized, the expected post-operative findings, imaging findings in pseudoarthrosis, and imaging definitions of fusion. CONCLUSION: Differentiating between pseudoarthrosis and arthrodesis in the postoperative spine is complex, and requires a robust understanding of various findings across many different modalities.


Subject(s)
Pseudarthrosis , Spinal Fusion , Diagnostic Imaging , Humans , Pseudarthrosis/diagnostic imaging , Pseudarthrosis/surgery , Spinal Fusion/methods , Spine , Treatment Outcome
20.
Neuroradiology ; 64(9): 1897-1903, 2022 Sep.
Article in English | MEDLINE | ID: mdl-35614322

ABSTRACT

Dynamic CT myelography is used to precisely localize fast spinal CSF leaks. The procedure is most commonly performed in the prone position, which successfully localizes most fast ventral leaks. We have recently encountered a small subset of patients in whom prone dynamic CT myelography is unsuccessful in localizing leaks. We sought to determine the added value of lateral decubitus dynamic CT myelography, which is occasionally attempted in our practice, in localizing the leak after failed prone dynamic CT myelography. We retrospectively identified 6 patients who underwent lateral decubitus dynamic CT myelography, which was performed in each case because their prone dynamic CT myelogram was unrevealing. Two neuroradiologists independently reviewed preprocedural spine MRI and all dynamic CT myelograms for each patient. Lateral decubitus positioning allowed for precise leak localization in all 6 patients. Five of six patients were noted to have dorsal and/or lateral epidural fluid collections on spine MRI. One patient had a single prominent diverticulum on spine MRI (larger than 6 mm), whereas the others had no prominent diverticula. Our study suggests that institutions performing dynamic CT myelography to localize fast leaks should consider a lateral decubitus study if performing the study in the prone position is unrevealing. Furthermore, the presence of dorsal and/or lateral epidural fluid collections on spine MRI may suggest that a lateral decubitus study is of higher yield and could be considered initially.


Subject(s)
Intracranial Hypotension , Myelography , Cerebrospinal Fluid Leak/complications , Cerebrospinal Fluid Leak/diagnostic imaging , Humans , Magnetic Resonance Imaging/methods , Myelography/methods , Retrospective Studies , Tomography, X-Ray Computed/methods
SELECTION OF CITATIONS
SEARCH DETAIL
...