Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add more filters










Database
Type of study
Language
Publication year range
1.
J Parkinsons Dis ; 10(4): 1763-1773, 2020.
Article in English | MEDLINE | ID: mdl-32925099

ABSTRACT

BACKGROUND: Gait impairments in Parkinson's disease (PD) are quantified using inertial sensors under standardized test settings in the hospital. Recent studies focused on the assessment of free-living gait in PD. However, the clinical relevance of standardized gait tests recorded at the patient's home is unclear. OBJECTIVE: To evaluate the reliability of supervised, standardized sensor-based gait outcomes at home compared to the hospital. METHODS: Patients with PD (n = 20) were rated by a trained investigator using the Unified Parkinson Disease Rating Scale (UPDRS-III). Gait tests included a standardized 4×10 m walk test and the Timed Up and Go Test (TUG). Tests were performed in the hospital (HOSPITAL) and at patients' home (HOME), and controlled for investigator, time of the day, and medication. Statistics included reliability analysis using Intra-Class correlations and Bland-Altman plots. RESULTS: UPDRS-III and TUG were comparable between HOSPITAL and HOME. PD patients' gait at HOME was slower (gait velocity Δ= -0.07±0.11 m/s, -6.1%), strides were shorter (stride length Δ= -9.2±9.4 cm; -7.3%), and shuffling of gait was more present (maximum toe-clearance Δ= -0.7±2.5 cm; -8.8%). Particularly, narrow walkways (<85 cm) resulted in a significant reduction of gait velocity at home. Reliability analysis (HOSPITAL vs. HOME) revealed excellent ICC coefficients for UPDRS-III (0.950, p < 0.000) and gait parameters (e.g., stride length: 0.898, p < 0.000; gait velocity: 0.914, p < 0.000; stance time: 0.922, p < 0.000; stride time: 0.907, p < 0.000). CONCLUSION: This pilot study underlined the clinical relevance of gait parameters by showing excellent reliability for supervised, standardized gait tests at HOSPITAL and HOME, even though gait parameters were different between test conditions.


Subject(s)
Exercise Test/standards , Gait Disorders, Neurologic/diagnosis , Monitoring, Ambulatory/standards , Parkinson Disease/diagnosis , Process Assessment, Health Care , Time and Motion Studies , Wearable Electronic Devices , Aged , Biomechanical Phenomena , Female , Gait Disorders, Neurologic/etiology , Hospitals , Humans , Male , Middle Aged , Parkinson Disease/complications , Pilot Projects , Reproducibility of Results , Severity of Illness Index , Telemedicine
SELECTION OF CITATIONS
SEARCH DETAIL
...