Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Int J Cardiol ; 283: 41-47, 2019 05 15.
Article in English | MEDLINE | ID: mdl-30545622

ABSTRACT

BACKGROUND: The clinical availability of high-sensitivity cardiac troponin (hs-cTn) has enabled the development of several innovative strategies for the rapid rule-out of acute myocardial infarction (AMI). Due to the lack of direct comparisons, selection of the best strategy for clinical practice is challenging. METHODS: In a prospective international multicenter diagnostic study enrolling 3696 patients presenting with suspected AMI to the emergency department, we compared the safety and efficacy of 14 different hs-cTn-based strategies: hs-cTn concentrations below the limit of detection (LoD), dual-marker combining hs-cTn with copeptin, ESC 0 h/1 h-algorithm, 0 h/2 h-algorithm, 2 h-ADP-algorithm, NICE-algorithm, and ESC 0 h/3 h-algorithm, each using either hs-cTnT or hs-cTnI. The final diagnosis of AMI was adjudicated by two independent cardiologists using all available clinical information including cardiac imaging and serial hs-cTn concentrations. RESULTS: AMI was the final diagnosis in 16% of patients. Using hs-cTnT, safety quantified by the negative predictive value (NPV) and sensitivity was very high (99.8-100% and 99.5-100%) and comparable for all strategies, except the dual-marker approach (NPV 98.7%, sensitivity 96.7%). Similarly, using hs-cTnI, safety quantified by the NPV and sensitivity was very high (99.7-100% and 98.9-100%) and comparable for all strategies, except the dual-marker approach (NPV 96.9%, sensitivity 90.4%) and the NICE-algorithm (NPV 99.1%, sensitivity 94.7%). Efficacy, quantified by the percentage of patients eligible for rule-out, differed markedly, and was lowest for LoD-algorithm (15.7-26.8%). CONCLUSION: All rapid rule-out algorithms, except the dual-marker strategy and the NICE-algorithm using hs-cTnI, favorably combine safety and efficacy, and can be considered for routine clinical practice. CLINICAL TRIAL REGISTRATION: NCT00470587, http://clinicaltrials.gov/show/NCT00470587.


Subject(s)
Algorithms , Myocardial Infarction/diagnosis , Practice Guidelines as Topic , Triage/standards , Troponin I/blood , Troponin T/blood , Aged , Aged, 80 and over , Biomarkers/blood , Coronary Angiography , Coronary Care Units , Electrocardiography , Female , Follow-Up Studies , Humans , Male , Middle Aged , Predictive Value of Tests , Prospective Studies , Time Factors
3.
Am Heart J ; 171(1): 92-102.e1-5, 2016 Jan.
Article in English | MEDLINE | ID: mdl-26699605

ABSTRACT

UNLABELLED: We aimed to prospectively derive and validate a novel 0-/1-hour algorithm using high-sensitivity cardiac troponin I (hs-cTnI) for the early "rule-out" and "rule-in" of acute myocardial infarction (AMI). METHODS: In a prospective multicenter diagnostic study, we enrolled 1,500 patients presenting with suspected AMI to the emergency department. The final diagnosis was centrally adjudicated by 2 independent cardiologists blinded to hs-cTnI concentrations. The hs-cTnI (Siemens Vista) 0-/1-hour algorithm incorporated measurements performed at baseline and absolute changes within 1 hour, was derived in the first 750 patients (derivation cohort), and then validated in the second 750 (validation cohort). RESULTS: Overall, AMI was the final diagnosis in 16% of patients. Applying the hs-cTnI 0-/1-hour algorithm developed in the derivation cohort to the validation cohort, 57% of patients could be classified as "rule-out"; 10%, as "rule-in"; and 33%, as "observe." In the validation cohort, the sensitivity and the negative predictive value for AMI in the "rule-out" zone were 100% (95% CI 96%-100%) and 100% (95% CI 99%-100%), respectively. The specificity and the positive predictive value (PPV) for AMI in the "rule-in" zone were 96% (95% CI 94%-97%) and 70% (95% CI 60%-79%), respectively. Negative predictive value and positive predictive value of the 0-/1-hour algorithm were higher compared to the standard of care combining hs-cTnI with the electrocardiogram (both P < .001). CONCLUSION: The hs-cTnI 0-/1-hour algorithm performs very well for early rule-out as well as rule-in of AMI. The clinical implications are that used in conjunction with all other clinical information, the 0-/1-hour algorithm will be a safe and effective approach to substantially reduce time to diagnosis.


Subject(s)
Algorithms , Electrocardiography , Myocardial Infarction/diagnosis , Troponin I/blood , Aged , Aged, 80 and over , Biomarkers/blood , Female , Follow-Up Studies , Humans , Male , Middle Aged , Myocardial Infarction/blood , Myocardial Infarction/mortality , Predictive Value of Tests , Prospective Studies , ROC Curve , Time Factors
SELECTION OF CITATIONS
SEARCH DETAIL
...