Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 77
Filter
1.
Micromachines (Basel) ; 15(6)2024 Jun 18.
Article in English | MEDLINE | ID: mdl-38930772

ABSTRACT

Future industrial applications of microparticle fractionation with deterministic lateral displacement (DLD) devices are hindered by exceedingly low throughput rates. To enable the necessary high-volume flows, high flow velocities as well as high aspect ratios in DLD devices have to be investigated. However, no experimental studies have yet been conducted on the fractionation of bi-disperse suspensions containing particles below 10 µm with DLD at a Reynolds number (Re) above 60. Furthermore, devices with an aspect ratio of more than 4:1, which require advanced microfabrication, are not known in the DLD literature. Therefore, we developed a suitable process with deep reactive ion etching of silicon and anodic bonding of a glass lid to create pressure-resistant arrays. With a depth of 120 µm and a gap of 23 µm between posts, a high aspect ratio of 6:1 was realized, and devices were investigated using simulations and fractionation experiments. With the two-segmented array of 3° and 7° row shifts, critical diameters of 8 µm and 12 µm were calculated for low Re conditions, but it was already known that vortices behind the posts can shift these values to lower critical diameters. Suspensions with polystyrene particles in different combinations were injected with an overall flow rate of up to 15 mL/min, corresponding to Re values of up to 90. Suspensions containing particle combinations of 2 µm with 10 µm as well as 5 µm with 10 µm were successfully fractionated, even at the highest flow rate. Under these conditions, a slight widening of the displacement position was observed, but there was no further reduction in the critical size as it was for Re = 60. With an unprecedented fractionation throughput of nearly 1 L per hour, entirely new applications are being developed for chemical, pharmaceutical, and recycling technologies.

2.
Sensors (Basel) ; 24(11)2024 May 28.
Article in English | MEDLINE | ID: mdl-38894266

ABSTRACT

This paper describes the design, fabrication, integration, characterization, and demonstration of a novel flexible double-sided curvature sensor array for use in soft robotics. The paper explores the performance and potential applications of a piezoresistive sensor array consisting of four gold strain gauges on a flexible polyimide (PI) substrate arranged in a Wheatstone bridge configuration. Multiple sensor strips were arranged like the fingers of a hand. Integrating Shape Memory Alloy (SMA) foils alongside the fingers was explored to mimic a human hand-gripping motion controlled with temperature, while curvature sensor array strips measure the resulting finger shapes. Moreover, object sensing in a flexible granular material gripper was demonstrated. The sensors were embedded within Polydimethylsiloxane (PDMS) to enhance their tactile feel and adhesive properties. The findings of this study are promising for future applications, particularly in robotics and prosthetics, as the ability to accurately mimic human hand movements and reconstruct sensor surfaces paves the way for robotic hand functionality.

3.
Pharmaceutics ; 15(10)2023 Oct 09.
Article in English | MEDLINE | ID: mdl-37896199

ABSTRACT

The nasal mucosa, being accessible and highly vascularized, opens up new opportunities for the systemic administration of drugs. However, there are several protective functions like the mucociliary clearance, a physiological barrier which represents is a difficult obstacle for drug candidates to overcome. For this reason, effective testing procedures are required in the preclinical phase of pharmaceutical development. Based on a recently reported immortalized porcine nasal epithelial cell line, we developed a test platform based on a tissue-compatible microfluidic chip. In this study, a biomimetic glass chip, which was equipped with a controlled bidirectional airflow to induce a physiologically relevant wall shear stress on the epithelial cell layer, was microfabricated. By developing a membrane transfer technique, the epithelial cell layer could be pre-cultivated in a static holder prior to cultivation in a microfluidic environment. The dynamic cultivation within the chip showed a homogenous distribution of the mucus film on top of the cell layer and a significant increase in cilia formation compared to the static cultivation condition. In addition, the recording of the ciliary transport mechanism by microparticle image velocimetry was successful. Using FITC-dextran 4000 as an example, it was shown that this nasal mucosa on a chip is suitable for permeation studies. The obtained permeation coefficient was in the range of values determined by means of other established in vitro and in vivo models. This novel nasal mucosa on chip could, in future, be automated and used as a substitute for animal testing.

4.
Pharmaceutics ; 15(9)2023 Aug 30.
Article in English | MEDLINE | ID: mdl-37765214

ABSTRACT

In recent years, there has been a significant increase in the registration of drugs for nasal application with systemic effects. Previous preclinical in vitro test systems for transmucosal drug absorption studies have mostly been based on primary cells or on tumor cell lines such as RPMI 2650, but both approaches have disadvantages. Therefore, the aim of this study was to establish and characterize a novel immortalized nasal epithelial cell line as the basis for an improved 3D cell culture model of the nasal mucosa. First, porcine primary cells were isolated and transfected. The P1 cell line obtained from this process was characterized in terms of its expression of tissue-specific properties, namely, mucus expression, cilia formation, and epithelial barrier formation. Using air-liquid interface cultivation, it was possible to achieve both high mucus formation and the development of functional cilia. Epithelial integrity was expressed as both transepithelial electrical resistance and mucosal permeability, which was determined for sodium fluorescein, rhodamine B, and FITC-dextran 4000. We noted a high comparability of the novel cell culture model with native excised nasal mucosa in terms of these measures. Thus, this novel cell line seems to offer a promising approach for developing 3D nasal mucosa tissues that exhibit favorable characteristics to be used as an in vitro system for testing drug delivery systems.

5.
Biosensors (Basel) ; 13(2)2023 Feb 16.
Article in English | MEDLINE | ID: mdl-36832047

ABSTRACT

Electrical impedance spectroscopy (EIS) is widely recognized as a powerful tool in biomedical research. For example, it allows detection and monitoring of diseases, measuring of cell density in bioreactors, and characterizing the permeability of tight junctions in barrier-forming tissue models. However, with single-channel measurement systems, only integral information is obtained without spatial resolution. Here we present a low-cost multichannel impedance measurement set-up capable of mapping cell distributions in a fluidic environment by using a microelectrode array (MEA) realized in 4-level printed circuit board (PCB) technology including layers for shielding, interconnections, and microelectrodes. The array of 8 × 8 gold microelectrode pairs was connected to home-built electric circuitry consisting of commercial components such as programmable multiplexers and an analog front-end module which allows the acquisition and processing of electrical impedances. For a proof-of-concept, the MEA was wetted in a 3D printed reservoir into which yeast cells were locally injected. Impedance maps were recorded at 200 kHz which correlate well with the optical images showing the yeast cell distribution in the reservoir. Blurring from parasitic currents slightly disturbing the impedance maps could be eliminated by deconvolution using an experimentally determined point spread function. The MEA of the impedance camera can in future be further miniaturized and integrated into cell cultivation and perfusion systems such as organ on chip devices to augment or even replace light microscopic monitoring of cell monolayer confluence and integrity during the cultivation in incubation chambers.


Subject(s)
Microscopy , Saccharomyces cerevisiae , Electric Impedance , Gold/chemistry , Microelectrodes
6.
Sensors (Basel) ; 23(4)2023 Feb 06.
Article in English | MEDLINE | ID: mdl-36850423

ABSTRACT

Observing the curing reaction of epoxy resins is a key to quality assurance in fibre composite production. The evaluation of electrical impedance spectra is an established monitoring method. Such impedance spectra contain the physical effects of dipole relaxation, ionic conduction and electrode polarisation, which shift to lower frequencies as curing progresses. In the early stage of the curing reaction, ionic conductivity and electrode polarisation dominate, and in the later stage of the curing reaction, dipole relaxation dominates. Due to the shift of the effects over several frequency decades, it makes sense to evaluate electrical impedance spectra not exclusively at one frequency but over an entire available frequency spectrum. The measured spectral raw data cannot be easily interpreted by a control algorithm and have to be mapped to simpler key indicators. For this purpose, a frequency-dependent model is proposed to address the aforementioned physical effects. With only five free parameters, measured spectra can be described with a relative error of only 2.3%. The shift of the occurring effects to lower frequencies necessitates switching the key indicator used in the progression of the cure reaction.

7.
Materials (Basel) ; 16(2)2023 Jan 07.
Article in English | MEDLINE | ID: mdl-36676333

ABSTRACT

Numerous synthetic techniques for the fabrication of porous metal electrodes were developed in recent decades. A very promising and facile route is the 3D printing of structures, which can be designed directly on the computer first. However, the current techniques allow structures to be printed with a resolution down to 20 µm, which is still quite rough regarding tuning the pore distribution and diameter of electrode materials for potential applications. For the first time, a laser-induced forward transfer (LIFT) process was used to 3D print metal voxels on a solid surface, resulting in a porous electrocatalytically active gold (Au) electrode film. Porous Au electrodes produced using LIFT showed an increase in the electrochemically active surface area (SA) by a factor of four compared with a sputtered dense Au film when characterized using cyclic voltammetry (CV) in Ar-saturated 0.1 M KOH. Therefore, the LIFT process can be considered very promising for the printing of ordered porous electrodes with high surface areas for electrochemical applications.

8.
Mikrochim Acta ; 190(2): 62, 2023 01 20.
Article in English | MEDLINE | ID: mdl-36662292

ABSTRACT

Antibody gold nanoparticle conjugates as recognition elements are essential for the overall performance of lateral flow assays. When immobilizing antibodies on gold nanoparticles, the challenge is to prevent aggregation and to ensure that the antibodies are correctly oriented so that they remain functional and their paratopes remain accessible. There are many methods available, and it is difficult to decide which one to use. To help selecting the most appropriate conjugate production method, different synthetic routes of binding antibodies to gold nanoparticles are systematically investigated for the purpose of a quantitative lateral flow test for small molecules. The direct comparison of different conjugate syntheses shows how to select a suitable conjugate for a lateral flow assay. The syntheses examined are direct adsorption of antibody, direct adsorption of reduced antibody, covalent binding to polyethylene glycol linker, and binding via biotin-streptavidin interaction. The conjugates are characterized using UV-Vis spectroscopy and dynamic light scattering to determine their stability. Their performance on structured lateral flow test strips is examined using calibrations for different amitriptyline concentrations. It was shown that the best conjugate for quantification of amitriptyline was realized by direct adsorption of an UV-light irradiated antibody to gold nanoparticles. The methods employed can serve as a guide for selecting the most appropriate conjugate for an application and enhance the performance of lateral flow assays.


Subject(s)
Gold , Metal Nanoparticles , Gold/chemistry , Amitriptyline , Metal Nanoparticles/chemistry , Antibodies , Immunoassay/methods
9.
Micromachines (Basel) ; 13(12)2022 Nov 25.
Article in English | MEDLINE | ID: mdl-36557375

ABSTRACT

The synthesis of nanoparticles in microchannels promises the advantages of small size, uniform shape and narrow size distribution. However, only with insights into the mixing processes can the most suitable designs and operating conditions be systematically determined. Coaxial lamination mixers (CLM) built by 2-photon polymerization can operate long-term stable nanoparticle precipitation without fouling issues. Contact of the organic phase with the microchannel walls is prevented while mixing with the aqueous phase is intensified. A coaxial nozzle allows 3D hydrodynamic focusing followed by a sequence of stretch-and-fold units. By means of a digital twin based on computational fluid dynamics (CFD) and numerical evaluation of mixing progression, the influences of operation conditions are now studied in detail. As a measure for homogenization, the mixing index (MI) was extracted as a function of microchannel position for different operating parameters such as the total flow rate and the share of solvent flow. As an exemplary result, behind a third stretch-and-fold unit, practically perfect mixing (MI>0.9) is predicted at total flow rates between 50 µL/min and 400 µL/min and up to 20% solvent flow share. Based on MI values, the mixing time, which is decisive for the size and dispersity of the nanoparticles, can be determined. Under the conditions considered, it ranges from 5 ms to 54 ms. A good correlation between the predicted mixing time and nanoparticle properties, as experimentally observed in earlier work, could be confirmed. The digital twin combining CFD with the MI methodology can in the future be used to adjust the design of a CLM or other micromixers to the desired total flow rates and flow rate ratios and to provide valuable predictions for the mixing time and even the properties of nanoparticles produced by microfluidic antisolvent precipitation.

10.
Sensors (Basel) ; 22(19)2022 Sep 26.
Article in English | MEDLINE | ID: mdl-36236400

ABSTRACT

The ability to measure the degree of cure of epoxy resins is an important prerequisite for making manufacturing processes for fibre-reinforced plastics controllable. Since a number of physical properties change during the curing reaction of epoxy resins, a wide variety of measurement methods exist. In this article, different methods for cure monitoring of epoxy resins are applied to a room-temperature curing epoxy resin and then directly compared. The methods investigated include a structure-borne sound acoustic, a dielectric, an optical and a strain-based observation method, which for the first time are measured simultaneously on one and the same resin sample. In addition, the degree of cure is determined using a kinetic resin model based on temperature measurement data. The comparison shows that the methods have considerable but well-explainable differences in their sensitivity, interference immunity and repeatability. Some measurement methods are only sensitive before and around the gel point, while the strain-based measurement method only reacts to the curing from the gel point onwards. These differences have to be taken into account when implementing a cure monitoring system. For this reason, a multi-sensor node is suitable for component-integrated curing monitoring, measuring several physical properties of the epoxy resin simultaneously.


Subject(s)
Epoxy Resins
11.
Materials (Basel) ; 15(19)2022 Sep 29.
Article in English | MEDLINE | ID: mdl-36234093

ABSTRACT

Structural health monitoring systems for composite laminates using guided ultrasonic waves become more versatile with the structural integration of sensors. However, the data generated within these sensors have to be transmitted from the laminate to the outside, where polyimide-based printed circuit boards play a major role. This study investigates, to what extent integrated polyimide inlays with applied sensor bodies influence the guided ultrasonic wave propagation in glass fiber-reinforced polymer specimens. For reasons of resource efficiency, narrow specimens are used. Numerical simulations of a damping-free specimen indicate reflections of the S0-mode at the integrated inlay. This is validated experimentally with an air-coupled ultrasonic technique and a 3D laser Doppler vibrometry measurement. The experimental data are evaluated with a method including temporal and spatial continuous wavelet transformations to clearly identify periodically occurring wave packages as edge reflections and distinguish them from possible inlay reflections. However, even when separating in-plane and out-of-plane movements using the 3D measurement, no reflections at the inlays are detected. This leads to the conclusion that polyimide inlays are well suited as substrates for printed circuit boards integrated into fiber-reinforced polymer structures for structural health monitoring, since they do not significantly influence the wave propagation.

12.
Polymers (Basel) ; 14(18)2022 Sep 13.
Article in English | MEDLINE | ID: mdl-36145961

ABSTRACT

An integrable sensor inlay for monitoring crack initiation and growth inside bondlines of structural carbon fiber-reinforced plastic (CFRP) components is presented. The sensing structures are sandwiched between crack-stopping poly(vinyliden fluoride) (PVDF) and a thin reinforcing polyetherimide (PEI) layer. Good adhesion at all interfaces of the sensor system and to the CFRP material is crucial, as weak bonds can counteract the desired crack-stopping functionality. At the same time, the chosen reinforcing layer must withstand high strains, safely support the metallic measuring grids, and possess outstanding fatigue strength. We show that this robust sensor system, which measures the strain at two successive fronts inside the bondline, allows to recognize cracks in the proximity of the inlay regardless of the mechanical loads. Feasibility is demonstrated by static load tests as well as cyclic long-term fatigue testing for up to 1,000,000 cycles. In addition to pure crack detection, crack distance estimation based on sensor signals is illustrated. The inlay integration process is developed with respect to industrial applicability. Thus, implementation of the proposed system will allow the potential of lightweight CFRP constructions to be better exploited by expanding the possibilities of structural adhesive bonding.

13.
Pharmaceutics ; 14(7)2022 Jul 12.
Article in English | MEDLINE | ID: mdl-35890346

ABSTRACT

One key application of organ-on-chip systems is the examination of drug transport and absorption through native cell barriers such the blood-brain barrier. To overcome previous hurdles related to the transferability of existing static cell cultivation protocols and polydimethylsiloxane (PDMS) as the construction material, a chip platform with key innovations for practical use in drug-permeation testing is presented. First, the design allows for the transfer of barrier-forming tissue into the microfluidic system after cells have been seeded on porous polymer or Si3N4 membranes. From this, we can follow highly reproducible models and cultivation protocols established for static drug testing, from coating the membrane to seeding the cells and cell analysis. Second, the perfusion system is a microscopable glass chip with two fluid compartments with transparent embedded electrodes separated by the membrane. The reversible closure in a clamping adapter requires only a very thin PDMS sealing with negligible liquid contact, thereby eliminating well-known disadvantages of PDMS, such as its limited usability in the quantitative measurements of hydrophobic drug molecule concentrations. Equipped with tissue transfer capabilities, perfusion chamber inertness and air bubble trapping, and supplemented with automated fluid control, the presented system is a promising platform for studying established in vitro models of tissue barriers under reproducible microfluidic perfusion conditions.

14.
Sensors (Basel) ; 22(14)2022 Jul 19.
Article in English | MEDLINE | ID: mdl-35891047

ABSTRACT

Structural health monitoring of lightweight constructions made of composite materials can be performed using guided ultrasonic waves. If modern fiber metal laminates are used, this requires integrated sensors that can record the inner displacement oscillations caused by the propagating guided ultrasonic waves. Therefore, we developed a robust MEMS vibrometer that can be integrated while maintaining the structural and functional compliance of the laminate. This vibrometer is directly sensitive to the high-frequency displacements from structure-borne ultrasound when excited in a frequency range between its first and second eigenfrequency. The vibrometer is mostly realized by processes earlier developed for a pressure sensor but with additional femtosecond laser ablation and encapsulation. The piezoresistive transducer, made from silicon, is encapsulated between top and bottom glass lids. The eigenfrequencies are experimentally determined using an optical micro vibrometer setup. The MEMS vibrometer functionality and usability for structural health monitoring are demonstrated on a customized test rig by recording application-relevant guided ultrasonic wave packages with a central frequency of 100 kHz at a distance of 0.2 m from the exciting ultrasound transducer.


Subject(s)
Micro-Electrical-Mechanical Systems , Lasers , Transducers , Ultrasonic Waves , Ultrasonography
15.
Biosensors (Basel) ; 12(7)2022 Jul 11.
Article in English | MEDLINE | ID: mdl-35884315

ABSTRACT

Microbioreactors (MBRs) with a volume below 1 mL are promising alternatives to established cultivation platforms such as shake flasks, lab-scale bioreactors and microtiter plates. Their main advantages are simple automatization and parallelization and the saving of expensive media components and test substances. These advantages are particularly pronounced in small-scale MBRs with a volume below 10 µL. However, most described small-scale MBRs are lacking in process information from integrated sensors due to limited space and sensor technology. Therefore, a novel capillary-wave microbioreactor (cwMBR) with a volume of only 7 µL has the potential to close this gap, as it combines a small volume with integrated sensors for biomass, pH, dissolved oxygen (DO) and glucose concentration. In the cwMBR, pH and DO are measured by established luminescent optical sensors on the bottom of the cwMBR. The novel glucose sensor is based on a modified oxygen sensor, which measures the oxygen uptake of glucose oxidase (GOx) in the presence of glucose up to a concentration of 15 mM. Furthermore, absorbance measurement allows biomass determination. The optical sensors enabled the characterization of an Escherichia coli batch cultivation over 8 h in the cwMBR as proof of concept for further bioprocesses. Hence, the cwMBR with integrated optical sensors has the potential for a wide range of microscale bioprocesses, including cell-based assays, screening applications and process development.


Subject(s)
Bioreactors , Oxygen , Biomass , Escherichia coli , Glucose
16.
Sensors (Basel) ; 22(13)2022 Jun 22.
Article in English | MEDLINE | ID: mdl-35808220

ABSTRACT

Systems-in-foil with multi-sensor arrays require extensive wiring with large numbers of data lines. This prevents scalability of the arrays and thus limits the applications. To enable multiplexing and thus reducing the external connections down to few digital data links and a power supply, active circuits in the form of ASICs must be integrated into the foils. However, this requires reliable multilayer wiring of the sensors and contacts for chip integration. As an elegant solution to this, a new manufacturing process for multilayer wiring in polyimide-based sensor foils has been developed that also allows ASIC chips to be soldered. The electrical four-level micro-via connections and the contact pads are generated by galvanic copper deposition after all other process steps, including stacking and curing of polyimide layers, are completed. Compared to layer by layer via technology, the processing time is considerably reduced. Because copper plating of vias and solderable copper contact pads happens as the final step, the risk of copper oxidation during polyimide curing is completely eliminated. The entire fabrication process is demonstrated for six strain sensor nodes connected to a surface-mounted ASIC as a detecting unit for sensing spatially resolved bending states. Each sensor node is a full-bridge configuration consisting of four strain gauges distributed across interconnected layers. The sensor foil allows bending of +/-120° without damage. This technology can be used in future for all kinds of complex flexible systems-in-foil, in particular for large arrays of sensors.

17.
Lab Chip ; 22(16): 3025-3044, 2022 08 09.
Article in English | MEDLINE | ID: mdl-35829631

ABSTRACT

Microfluidic mixers promise unique conditions for the controlled and continuous preparation of nanoparticles by antisolvent precipitation. Nanoparticles may enable encapsulation of drug or mRNA molecules in the form of carrier nanoparticles or can provide higher bioavailability in the form of drug nanoparticles. The ultimate goal in microfluidic approaches is the production of nanoparticles with narrow size distributions while avoiding contaminations and achieving sufficiently high throughput. To achieve this, a novel microfluidic precipitation device was developed and realized by two-photon polymerization: mixing elements were designed in such a way that the liquids undergo a repeated Smale horseshoe transformation resulting in an increased interfacial area and mixing times of less than 10 ms. These elements and an additional 3D flow focusing ensure that no organic phase is exposed to the channel walls. The integration of a fluidic shield layer in the flow focusing proved to be useful to delay the precipitation process until reaching a sufficient distance to the injection nozzle. Lipid nanoparticle preparation with different concentrations of castor oil or the hard fat Softisan® 100 were performed at different flow rates and mixing ratios with and without a shield layer. Flow rates of up to 800 µl min-1 and organic phase mixing ratios of up to 20% resulted in particle sizes ranging from 42 nm to 166 nm with polydispersity indices from 0.04 to 0.11, indicating very narrowly distributed, and in most cases even monodisperse, nanoparticles. The occurrence of fouling can be completely suppressed with this new type of mixing elements, as long as Dean vortices are prevented. Moreover, this parameter range in the horseshoe lamination mixer provided a stable and continuous process, which enables a scalable production.


Subject(s)
Nanoparticles , Liposomes , Microfluidics/methods , Particle Size
18.
Sensors (Basel) ; 22(11)2022 May 31.
Article in English | MEDLINE | ID: mdl-35684817

ABSTRACT

Continuous health monitoring in a vehicle enables the earlier detection of symptoms of cardiovascular diseases. In this work, we designed flexible and thin electrodes made of polyurethane for long-term electrocardiogram (ECG) monitoring while driving. We determined the time for reliable ECG recording to evaluate the effectiveness of the electrodes. We recorded data from 19 subjects under four scenarios: rest, city, highway, and rural. The recording time was five min for rest and 15 min for the other scenarios. The total recording (950 min) is publicly available under a CC BY-ND 4.0 license. We used the simultaneous truth and performance level estimation (STAPLE) algorithm to detect the position of R-waves. Then, we derived the RR intervals to compare the estimated heart rate with the ground truth, which we obtained from ECG electrodes on the chest. We calculated the signal-to-noise ratio (SNR) and averaged it for the different scenarios. Highway had the lowest SNR (-6.69 dB) and rural had the highest (-6.80 dB). The usable time of the steering wheel was 42.46% (city), 46.67% (highway), and 47.72% (rural). This indicates that steering-wheel-based ECG recording is feasible and delivers reliable recordings from about 45.62% of the driving time. In summary, the developed electrodes allow continuous in-vehicle heart rate monitoring, and our publicly available recordings provide the opportunity to apply more sophisticated data analytics.


Subject(s)
Automobile Driving , Electrocardiography , Electrodes , Heart Rate , Humans , Monitoring, Physiologic
19.
ACS Omega ; 7(21): 17519-17527, 2022 May 31.
Article in English | MEDLINE | ID: mdl-35664585

ABSTRACT

In this research, we designed and fabricated an optofluidic chip for the detection and differentiation of single particles via the combination of backscattered (BSC) and forward-scattered (FSC) or side-scattered (SSC) light intensity. The high sensitivity of BSC light to the refractive index of the particles enabled an effective approach for the differentiation of individual particles based on the type of material. By recording BSC as well as FSC and SSC light intensities from single particles, transiting through the illumination zone in a microfluidic channel, the size and type of material could be detected simultaneously. The analysis of model samples of polystyrene (PS), as a primary microplastic particle, and silica microspheres showed substantially higher BSC signal values of PS because of a larger refractive index compared to the silica. The scatter plots correlating contributions of BSC (FSC-BSC and SSC-BSC) allowed a clear differentiation of PS and silica particles. To demonstrate the great potential of this methodology, two "real-life" samples containing different types of particles were tested as application examples. Commercial toothpaste and peeling gel products, as primary sources of microplastics into effluents, were analyzed via the optofluidic chip and compared to results from scanning electron microscopy. The scattering analysis of the complex samples enabled the detection and simultaneous differentiation of particles such as microplastics according to their differences in the refractive index via distinctive areas of high and low BSC signal values. Hence, the contribution of BSC light measurements in multiangle scattering of single particles realized in an optofluidic chip opens the way for the discrimination of single particles in a liquid medium in manifold fields of application ranging from environmental monitoring to cosmetics.

20.
Bioengineering (Basel) ; 9(2)2022 Feb 09.
Article in English | MEDLINE | ID: mdl-35200420

ABSTRACT

To improve the predictive value of in vitro experimentation, the use of 3D cell culture models, or organoids, is becoming increasingly popular. However, the current equipment of life science laboratories has been developed to deal with cell monolayers or cell suspensions. To handle 3D cell aggregates and organoids in a well-controlled manner, without causing structural damage or disturbing the function of interest, new instrumentation is needed. In particular, the precise and stable positioning in a cell bath with flow rates sufficient to characterize the kinetic responses to physiological or pharmacological stimuli can be a demanding task. Here, we present data that demonstrate that microgrippers are well suited to this task. The current version is able to work in aqueous solutions and was shown to position isolated pancreatic islets and 3D aggregates of insulin-secreting MIN6-cells. A stable hold required a gripping force of less than 30 µN and did not affect the cellular integrity. It was maintained even with high flow rates of the bath perfusion, and it was precise enough to permit the simultaneous microfluorimetric measurements and membrane potential measurements of the single cells within the islet through the use of patch-clamp electrodes.

SELECTION OF CITATIONS
SEARCH DETAIL
...