Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 39
Filter
1.
BJR Open ; 6(1): tzae015, 2024 Jan.
Article in English | MEDLINE | ID: mdl-39021509

ABSTRACT

Recent advancements in CT technology have introduced a revolutionary innovation to practice known as the Photon-Counting detector (PCD) CT imaging. The pivotal hardware enhancement of the PCD-CT scanner lies in its detectors, which consist of smaller pixels than standard detectors and allow direct conversion of individual X-rays to electrical signals. As a result, CT images are reconstructed at higher spatial resolution (as low as 0.2 mm) and reduced overall noise, at no expense of an increased radiation dose. These features are crucial for paediatric imaging, especially for infants and young children, where anatomical structures are notably smaller than in adults and in whom keeping dose as low as possible is especially relevant. Since January 2022, our hospital has had the opportunity to work with PCD-CT technology for paediatric imaging. This pictorial review will showcase clinical examples of PCD-CT imaging in children. The aim of this pictorial review is to outline the potential paediatric applications of PCD-CT across different anatomical regions, as well as to discuss the benefits in utilizing PCD-CT in comparison to conventional standard energy integrating detector CT.

2.
PeerJ ; 12: e16541, 2024.
Article in English | MEDLINE | ID: mdl-38774542

ABSTRACT

In the Western Scheldt Estuary near the Belgian-Dutch border, middle to late Eocene strata crop out at the current seafloor. Most vertebrae of large Eocene basilosaurid taxa from this area were previously described in several papers. They represent three morphotypes: elongated vertebrae of a large species of Pachycetus (Morphotype 1b), a not-elongated vertebra of a large 'dorudontid' basilosaurid (Morphotype 2) and 'shortened' vertebrae of a new, unnamed taxon (Morphotype 3). This article deals with a still undescribed, smaller vertebra, NMR-16642, from this site. Our first aim was to date it by dinoflagellate cysts in adhering sediments. Yielding an age of about 38 Ma, it is one of the very few remains of basilosaurids from Europe, of which the age could be assessed with reasonable certainty. The vertebra, Morphotype 1a, is assigned to a small species of Pachycetus. High-quality CT scans are used to differentiate between NMR-16642, Morphotype 1a, and the large species of Pachycetus, Morphotype 1b. Another aim of this paper is to investigate the inner structure and vascularity of the study vertebra and that of the other morphotypes (1b, 2, 3) from this area by using high-quality CT scans. Notwithstanding differences in size, shape and compactness, the vertebral inner structure with a multi-layered cortex of periosteal bone, surrounding two cones of endosteal bone appears to be basically similar in all morphotypes. Apparently, this inner structure reflects the ontogenetic vertebral growth. An attempt to reconstruct the vascularity of the vertebrae reveals a remarkable pattern of interconnected vascular systems. From the dorsal and, if present, ventral foramina, vascular canals are running to a central vascular node. From this node a system of vascular canals goes to the epiphyseal ends, giving rise to separate systems for cortex and cones. It is the first time that the vascularity of vertebrae of archaeocetes is investigated.


Subject(s)
Fossils , Spine , Animals , Spine/anatomy & histology , Spine/blood supply , North Sea , Dinosaurs/anatomy & histology , Dinosaurs/classification , Tomography, X-Ray Computed
3.
Med Phys ; 51(4): 2924-2932, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38358113

ABSTRACT

BACKGROUND: Photon-counting CT (PCCT) is the next-generation CT scanner that enables improved spatial resolution and spectral imaging. For full spectral processing, higher tube voltages compared to conventional CT are necessary to achieve the required spectral separation. This generated interest in the potential influence of thin slice high tube voltage PCCT on overall image quality and consequently on radiation dose. PURPOSE: This study first evaluated tube voltages and radiation doses applied in patients who underwent coronary CT angiography with PCCT and energy-integrating detector CT (EID-CT). Next, image quality of PCCT and EID-CT was objectively evaluated in a phantom study simulating different patient sizes at these tube voltages and radiation doses. METHODS: We conducted a retrospective analysis of clinical doses of patients scanned on a conventional and PCCT system. Average patient water equivalent diameters for different tube voltages were extracted from the dose reports for both EID-CT and PCCT. A conical phantom made of polyethylene with multiple diameters (26/31/36 cm) representing different patient sizes and containing an iodine insert was scanned with a EID-CT scanner using tube voltages and phantom diameters that match the patient scans and characteristics. Next, phantom scans were made with PCCT at a fixed tube voltage of 120 kV and with CTDIVOL values and phantom diameters identical to the EID-CT scans. Clinical image reconstructions at 0.6 mm slice thickness for conventional CT were compared to PCCT images with 0.4 mm slice thickness. Image quality was quantified using the detectability index (d'), which estimated the visibility of a 3 mm diameter contrast-enhanced coronary artery by considering noise, contrast, resolution, and human visual perception. Alongside d', noise, contrast and resolution were also individually assessed. In addition, the influence of various kernels (Bv40/Bv44/Bv48/Bv56), quantum iterative reconstruction strengths (QIR, 3/4) and monoenergetic levels (40/45/50/55 keV) for PCCT on d' was investigated. RESULTS: In this study, 143 patients were included: 47 were scanned on PCCT (120 kV) and the remaining on EID-CT (74 small-sized at 70 kV, 18 medium-sized at 80 kV and four large-sized at 90 kV). EID-CT showed 7%-17% higher d' than PCCT with Bv40 kernel and strength four for small/medium patients. Lower monoenergetic images (40 keV) helped mitigate the difference to 1%-6%. For large patients, PCCT's detectability was up to 31% higher than EID-CT. PCCT has thinner slices but similar noise levels for similar reconstruction parameters. The noise increased with lower keV levels in PCCT (≈30% increase), but higher QIR strengths reduced noise. PCCT's iodine contrast was stable across patient sizes, while EID-CT had 33% less contrast in large patients than in small-sized patients. CONCLUSION: At 120 kV, thin slice PCCT enables CCTA in phantom scans representing large patients without raising radiation dose or affecting vessel detectability. However, higher doses are needed for small and medium-sized patients to obtain a similar image quality as in EID-CT. The alternative of using lower mono-energetic levels requires further evaluation in clinical practice.


Subject(s)
Iodine , Tomography, X-Ray Computed , Humans , Coronary Angiography , Retrospective Studies , Tomography, X-Ray Computed/methods , Phantoms, Imaging , Radiation Dosage , Photons
4.
Eur J Radiol ; 171: 111282, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38190778

ABSTRACT

PURPOSE: The study is intended to assess the image quality of ultra-high resolution (UHR) coronary computed tomography angiography (CCTA) performed on dual source photon-counting detector CT (PCD-CT). METHOD: Consecutive patients, who underwent clinically indicated CCTA on PCD-CT (UHR 120x 0.2 mm collimation), were included. CCTA images were reconstructed at 0.2 mm slice thickness with Bv40, Bv44, Bv48 and Bv56 kernels and quantum iterative reconstruction level 4. Contrast-to-noise (CNR) and signal-to-noise ratios (SNR) were quantified from contrast-enhanced blood and subcutaneous adipose tissue. All reconstructions were scored per coronary segment (18-segment model) for presence, image quality, motion artefacts, stack artefacts, plaque presence and composition, and stenosis degree. Image quality was scored by two independent observers. RESULTS: Sixty patients were included (median age 62 [25th - 75th percentile: 53-67] years, 45% male, median calcium score 62 [0-217]). The mean heart rate during scanning was 71 ± 11 bpm. Median CTDIvol was 19 [16-22]mGy and median DLP 243 [198-327]mGy.cm. The SNR was 9.3 ± 2.3 and the CNR was 11.7 ± 2.6. Of the potential 1080 coronary segments (60 patients x 18 segments), 255/256 (reader1/reader2) segments could not be assessed for being absent or non-evaluable due to size. Both readers scored 85% of the segments as excellent or very good (Intraclass Correlation Coefficient: 0.88 (95% CI: 0.87-0.90). Motion artefacts were present in 45(5%) segments, stack artefacts in 60(7%) segments and metal artefacts in 9(1%) segments. CONCLUSION: UHR dual-source PCD-CT CCTA provides excellent or very good image quality in 85% of coronary segments at relatively high heart rates at moderate radiation dose with only limited stack artefacts.


Subject(s)
Coronary Vessels , Tomography, X-Ray Computed , Humans , Male , Middle Aged , Female , Coronary Angiography/methods , Coronary Vessels/diagnostic imaging , Tomography, X-Ray Computed/methods , Computed Tomography Angiography/methods , Heart , Phantoms, Imaging
5.
PLoS One ; 18(11): e0293456, 2023.
Article in English | MEDLINE | ID: mdl-37956141

ABSTRACT

BACKGROUND: Clot composition, contraction, and mechanical properties are likely determinants of endovascular thrombectomy success. A pre-interventional estimation of these properties is hypothesized to aid in selecting the most suitable treatment for different types of thrombi. Here we determined the association between the aforementioned properties and computed tomography (CT) characteristics using human blood clot analogues. METHODS: Clot analogues were prepared from the blood of 4 healthy human donors with 5 red blood cell (RBC) volume suspensions: 0%, 20%, 40%, 60% and 80% RBCs. Contraction was measured as the weight of the contracted clots as a percentage of the original suspension. The clots were imaged using CT with and without contrast to quantify clot density and density increase. Unconfined compression was performed to determine the high strain compressive stiffness. The RBC content was analysed using H&E staining. RESULTS: The 5 RBC suspensions formed only two groups of clots, fibrin-rich (0% RBCs) and RBC-rich (>90% RBCs), as determined by histology. The density of the fibrin-rich clots was significantly lower (31-38HU) compared to the RBC-rich clots (72-89HU), and the density increase of the fibrin-rich clots was significantly higher (82-127HU) compared to the RBC-rich clots (3-17HU). The compressive stiffness of the fibrin-rich clots was higher (178-1624 kPa) than the stiffness of the RBC-rich clots (6-526 kPa). Additionally, the degree of clot contraction was higher for the fibrin-rich clots (89-96%) compared to the RBC-rich clots (11-77%). CONCLUSIONS: CT imaging clearly reflects clot RBC content and seems to be related to the clot contraction and stiffness. CT imaging might be a useful tool in predicting the thrombus characteristics. However, future studies should confirm these findings by analysing clots with intermediate RBC and platelet content.


Subject(s)
Thromboembolism , Thrombosis , Humans , Thrombosis/pathology , Tomography, X-Ray Computed/methods , Thrombectomy/methods , Thromboembolism/pathology , Fibrin , Erythrocytes/pathology
6.
Eur Radiol ; 2023 Nov 09.
Article in English | MEDLINE | ID: mdl-37940711

ABSTRACT

OBJECTIVES: To compare coronary artery calcification (CAC) scores measured on virtual non-contrast (VNC) and virtual non-iodine (VNI) reconstructions computed from coronary computed tomography angiography (CCTA) using photon-counting computed tomography (PCCT) to true non-contrast (TNC) images. METHODS: We included 88 patients (mean age = 59 years ± 13.5, 69% male) who underwent a TNC coronary calcium scan followed by CCTA on PCCT. VNC images were reconstructed in 87 patients and VNI in 88 patients by virtually removing iodine from the CCTA images. For all reconstructions, CAC scores were determined, and patients were classified into risk categories. The overall agreement of the reconstructions was analyzed by Bland-Altman plots and the level of matching classifications. RESULTS: The median CAC score on TNC was 27.8 [0-360.4] compared to 8.5 [0.2-101.6] (p < 0.001) on VNC and 72.2 [1.3-398.8] (p < 0.001) on VNI. Bland-Altman plots depicted a bias of 148.8 (ICC = 0.82, p < 0.001) and - 57.7 (ICC = 0.95, p < 0.001) for VNC and VNI, respectively. Of all patients with CACTNC = 0, VNC reconstructions scored 63% of the patients correctly, while VNI scored 54% correctly. Of the patients with CACTNC > 0, VNC and VNI reconstructions detected the presence of coronary calcium in 90% and 92% of the patients. CACVNC tended to underestimate CAC score, whereas CACVNI overestimated, especially in the lower risk categories. According to the risk categories, VNC misclassified 55% of the patients, while VNI misclassified only 32%. CONCLUSION: Compared to TNC images, VNC underestimated and VNI overestimated the actual CAC scores. VNI reconstructions quantify and classify coronary calcification scores more accurately than VNC reconstructions. CLINICAL RELEVANCE STATEMENT: Photon-counting CT enables spectral imaging, which might obviate the need for non-contrast enhanced coronary calcium scoring, but optimization is necessary for the clinical implementation of the algorithms. KEY POINTS: • Photon-counting computed tomography uses spectral information to virtually remove the signal of contrast agents from contrast-enhanced scans. • Virtual non-contrast reconstructions tend to underestimate coronary artery calcium scores compared to true non-contrast images, while virtual non-iodine reconstructions tend to overestimate the calcium scores. • Virtual non-iodine reconstructions might obviate the need for non-contrast enhanced calcium scoring, but optimization is necessary for the clinical implementation of the algorithms.

7.
Radiol Cardiothorac Imaging ; 5(2): e220318, 2023 Apr.
Article in English | MEDLINE | ID: mdl-37124634

ABSTRACT

Photon-counting detector CT (PCD CT) has increasingly garnered interest in cardiothoracic imaging due to its high spatial resolution and ability to perform spectral imaging. CT plays an important role in the planning and postprocedural assessment of transcatheter aortic valve replacement (TAVR). Limitations of current CT technology resulting in blooming and metal artifacts may be addressed with PCD CT. This case series demonstrates the potential advantages of PCD CT in patients prior to and post-TAVR. In TAVR planning, PCD CT allowed for a detailed depiction of the aortic valve, aortic root, coronary arteries, and potential vascular access routes. The high-spatial-resolution reconstructions enabled assessment of hypoattenuating leaflet thickening and periprosthetic leakage for prosthetic valves. This study shows promising initial results, but further research is needed to determine the clinical impact of PCD CT in patients prior to and post-TAVR. Keywords: Transcatheter Aortic Valve Replacement, Cardiac, Coronary Arteries, Heart, Valves, Photon-counting Detector CT © RSNA, 2023 An earlier incorrect version appeared online. This article was corrected on October 27, 2023.

8.
Eur J Radiol ; 163: 110829, 2023 Jun.
Article in English | MEDLINE | ID: mdl-37080060

ABSTRACT

Photon-counting computed tomography (PCCT) is a new technology that enables higher spatial resolution compared to conventional CT techniques, energy resolved imaging and spectral post-processing. This leads to improved contrast-to-noise ratio, artifact and potential dose reduction as well as elimination of electronic noise. Since the introduction of clinical PCCT in 2021, a shift has been observed from solely pre-clinical studies to clinical research (i.e. use of PCCT imaging in humans). This review article is focused on the initial clinical results of PCCT by explaining the current PCCT systems, the applications themselves and, the challenges of PCCT.


Subject(s)
Tomography, X-Ray Computed , Humans , Phantoms, Imaging , Tomography, X-Ray Computed/methods
9.
Transpl Int ; 36: 10647, 2023.
Article in English | MEDLINE | ID: mdl-36756277

ABSTRACT

Aorto-iliac calcification (AIC) is a well-studied risk factor for post-transplant cardiovascular events and mortality. Its effect on graft function remains unknown. The primary aim of this prospective cohort study was to assess the association between AIC and estimated glomerular filtration rate (eGFR) in the first year post-transplant. Eligibility criteria were: ≥50 years of age or ≥30 years with at least one risk factor for vascular disease. A non-contrast-enhanced CT-scan was performed with quantification of AIC using the modified Agatston score. The association between AIC and eGFR was investigated with a linear mixed model adjusted for predefined variables. One-hundred-and-forty patients were included with a median of 31 (interquartile range 26-39) eGFR measurements per patient. No direct association between AIC and eGFR was found. We observed a significant interaction between follow-up time and ipsilateral AIC, indicating that patients with higher AIC scores had lower eGFR trajectory over time starting 100 days after transplant (p = 0.014). To conclude, severe AIC is not directly associated with lower post-transplant eGFR. The significant interaction indicates that patients with more severe AIC have a lower eGFR trajectory after 100 days in the first year post-transplant.


Subject(s)
Kidney Transplantation , Humans , Adult , Kidney Transplantation/adverse effects , Glomerular Filtration Rate , Prospective Studies , Risk Factors
11.
Diagnostics (Basel) ; 12(6)2022 Jun 14.
Article in English | MEDLINE | ID: mdl-35741277

ABSTRACT

To evaluate whether the contrast-to-noise ratio (CNR) of an iodinated contrast agent in virtual monoenergetic images (VMI) from the first clinical photon-counting detector (PCD) CT scanner is superior to VMI CNR from a dual-source dual-energy CT scanner with energy-integrating detectors (EID), two anthropomorphic phantoms in three different sizes (thorax and abdomen, QRM GmbH), in combination with a custom-built insert containing cavities filled with water, and water with 15 mg iodine/mL, were scanned on an EID-based scanner (Siemens SOMATOM Force) and on a PCD-based scanner (Siemens, NAEOTOM Alpha). VMI (range 40−100 keV) were reconstructed without an iterative reconstruction (IR) technique and with an IR strength of 60% for the EID technique (ADMIRE) and closest matching IR strengths of 50% and 75% for the PCD technique (QIR). CNR was defined as the difference in mean CT numbers of water, and water with iodine, divided by the root mean square value of the measured noise in water, and water with iodine. A two-sample t-test was performed to evaluate differences in CNR between images. A p-value < 0.05 was considered statistically significant. For VMI without IR and below 60 keV, the CNR of the PCD-based images at 120 and 90 kVp was up to 55% and 75% higher than the CNR of the EID-based images, respectively (p < 0.05). For VMI above 60 keV, CNRs of PCD-based images at both 120 and 90 kVp were up to 20% lower than the CNRs of EID-based images. Similar or improved performance of PCD-based images in comparison with EID-based images were observed for VMIs reconstructed with IR techniques. In conclusion, with PCD-CT, iodine CNR on low energy VMI (<60 keV) is better than with EID-CT.

12.
Eur J Radiol ; 131: 109261, 2020 Oct.
Article in English | MEDLINE | ID: mdl-32937253

ABSTRACT

Since the introduction of Computed Tomography (CT), technological improvements have been impressive. At the same time, the number of adjustable acquisition and reconstruction parameters has increased substantially. Overall, these developments led to improved image quality at a reduced radiation dose. However, many parameters are interrelated and part of automated algorithms. This makes it more complicated to adjust them individually and more difficult to comprehend their influence on CT protocol adjustments. Moreover, the user's influence in adapting protocol parameters is sometimes limited by the manufacturer's policy or the user's knowledge. As a consequence, optimization can be a challenge. A literature search in Embase, Medline, Cochrane, and Web of Science was performed. The literature was reviewed with the objective to collect information regarding technological developments in CT over the past five decades and the role of the associated acquisition and reconstruction parameters in the optimization process.


Subject(s)
Tomography, X-Ray Computed/trends , Algorithms , Forecasting , Humans , Radiation Dosage , Radiographic Image Interpretation, Computer-Assisted/methods , Tomography, X-Ray Computed/methods
13.
Eur Radiol ; 29(4): 2079-2088, 2019 Apr.
Article in English | MEDLINE | ID: mdl-30306328

ABSTRACT

OBJECTIVE: To assess the accuracy of a 3D camera for body contour detection and patient positioning in CT compared to routine manual positioning by radiographers. METHODS AND MATERIALS: Four hundred twenty-three patients that underwent CT of the head, thorax, and/or abdomen on a scanner with manual table height selection and 254 patients on a scanner with table height suggestion by a 3D camera were retrospectively included. Within the camera group, table height suggestion was based on infrared body contour detection and fitting of a scalable patient model to the 3D data. Proper positioning was defined as the ideal table height at which the scanner isocenter coincides with the patient's isocenter. Patient isocenter was computed by automatic skin contour extraction in each axial image and averaged over all images. Table heights suggested by the camera and selected by the radiographer were compared with the ideal height. RESULTS: Median (interquartile range) absolute table height deviation in millimeter was 12.0 (21.6) for abdomen, 12.2 (12.0) for head, 13.4 (17.6) for thorax-abdomen, and 14.7 (17.3) for thorax CT scans positioned by radiographers. The deviation was significantly less (p < 0.01) for the 3D camera at 6.3 (6.9) for abdomen, 9.5 (6.8) for head, 6.0 (6.1) for thorax-abdomen, and 5.4 (6.4) mm for thorax. CONCLUSION: A 3D camera for body contour detection allows for accurate patient positioning, thereby outperforming manual positioning done by radiographers, resulting in significantly smaller deviations from the ideal table height. However, radiographers remain indispensable when the system fails or in challenging cases. KEY POINTS: • A 3D camera for body contour detection allows for accurate patient positioning. • A 3D camera outperformed radiographers in patient positioning in CT. • Deviation from ideal table height was more extreme for patients positioned by radiographers for all body parts.


Subject(s)
Abdomen/diagnostic imaging , Head/diagnostic imaging , Imaging, Three-Dimensional/instrumentation , Patient Positioning/methods , Thorax/diagnostic imaging , Tomography, X-Ray Computed/methods , Whole Body Imaging/methods , Female , Humans , Male , Retrospective Studies
14.
Exp Clin Transplant ; 16(1): 16-22, 2018 Feb.
Article in English | MEDLINE | ID: mdl-28810823

ABSTRACT

OBJECTIVES: To investigate the kidney selection procedure before donation to maximize donor safety, we investigated whether ultrasonographic measurements of kidney volume are comparable with computed tomography measurements. Predonation volume and increases in kidney size may be important indicators of renal function after donation and subsequent loss of function. MATERIALS AND METHODS: Consecutive donors with predonation computed tomography scans were approached preoperatively for additional ultrasonographic examinations. Measurements were independently performed by 2 ultrasonographers and considered accurate when the mean differences between both examiners for length, width, and thickness of the kidneys were < 5 mm. Ultrasonographic volumes were calculated with the ellipsoid equation (length × width × thickness × π/6) and an adjusted equation (length × width × thickness × 0.674), and computed tomography volumes were calculated with the voxel count method, which is considered the criterion standard. RESULTS: For this study (Dutch Trial Register NTR3795), 100 kidneys were measured. The mean differences between examiner 1 and 2 for similar ultrasonography measurements were < 5 mm. The ellipsoid equation underestimated the volume for examiner 1 by 16.9% and for examiner 2 by 14.8%, whereas the adjusted equation overestimated the volume by 6.8% and 9.5% respectively. The correlation between computed tomography and ultrasonographic volume with the adjusted equation was strong for both examiner 1 (r = 0.76; P < .001) and examiner 2 (r = 0.80; P < .001). CONCLUSIONS: Ultrasonographic measurements of kidney volume are comparable with computed tomography measurements. Therefore, ultrasonography is a reliable modality for living kidney donor follow-up monitoring of kidney size adaption after donation.


Subject(s)
Donor Selection/methods , Kidney Transplantation/methods , Kidney/diagnostic imaging , Living Donors , Ultrasonography , Adaptation, Physiological , Adult , Aged , Female , Humans , Kidney/surgery , Male , Middle Aged , Multidetector Computed Tomography , Nephrectomy , Netherlands , Observer Variation , Organ Size , Predictive Value of Tests , Reproducibility of Results
15.
Eur Radiol ; 28(5): 2159-2168, 2018 May.
Article in English | MEDLINE | ID: mdl-29234912

ABSTRACT

OBJECTIVES: Multidetector CT (MDCT) is a valuable tool for functional prosthetic heart valve (PHV) assessment. However, radiation exposure remains a concern. We assessed a novel CT-acquisition protocol for comprehensive PHV evaluation at limited dose. METHODS: Patients with a PHV were scanned using a third-generation dual-source CT scanner (DSCT) and iterative reconstruction technique (IR). Three acquisitions were obtained: a non-enhanced scan; a contrast-enhanced, ECG-triggered, arterial CT angiography (CTA) scan with reconstructions at each 5 % of the R-R interval; and a delayed high-pitch CTA of the entire chest. Image quality was scored on a five-point scale. Radiation dose was obtained from the reported CT dose index (CTDI) and dose length product (DLP). RESULTS: We analysed 43 CT examinations. Mean image quality score was 4.1±1.4, 4.7±0.5 and 4.2±0.6 for the non-contrast-enhanced, arterial and delayed acquisitions, respectively, with a total mean image quality of 4.3±0.7. Mean image quality for leaflet motion was 3.9±1.4. Mean DLP was 28.2±17.1, 457.3±168.6 and 68.5±47.2 mGy.cm for the non-contrast-enhanced (n=40), arterial (n=43) and delayed acquisition (n=43), respectively. The mean total DLP was 569±208 mGy.cm and mean total radiation dose was 8.3±3.0 mSv (n=43). CONCLUSION: Comprehensive assessment of PHVs is possible using DSCT and IR at moderate radiation dose. KEY POINTS: • Prosthetic heart valve dysfunction is a potentially life-threatening condition. • Dual-source CT can adequately assess valve leaflet motion and anatomy. • We assessed a comprehensive protocol with three acquisitions for PHV evaluation. • This protocol is associated with good image quality and limited dose.


Subject(s)
Heart Valve Prosthesis , Heart Valves/diagnostic imaging , Multidetector Computed Tomography/methods , Radiographic Image Interpretation, Computer-Assisted/methods , Female , Humans , Male , Middle Aged , Radiation Dosage
16.
Int J Cardiovasc Imaging ; 33(12): 1895-1903, 2017 Dec.
Article in English | MEDLINE | ID: mdl-28631106

ABSTRACT

Integration of volumetric heart chamber quantification by 3D echocardiography into clinical practice has been hampered by several factors which a new fully automated algorithm (Left Heart Model, (LHM)) may help overcome. This study therefore aims to evaluate the feasibility and accuracy of the LHM software in quantifying left atrial and left ventricular volumes and left ventricular ejection fraction in a cohort of patients with a bicuspid aortic valve. Patients with a bicuspid aortic valve were prospectively included. All patients underwent 2D and 3D transthoracic echocardiography and computed tomography. Left atrial and ventricular volumes were obtained using the automated program, which did not require manual contour detection. For comparison manual and semi-automated measurements were performed using conventional 2D and 3D datasets. 53 patients were included, in four of those patients no 3D dataset could be acquired. Additionally, 12 patients were excluded based on poor imaging quality. Left ventricular end-diastolic and end-systolic volumes and ejection fraction calculated by the LHM correlated well with manual 2D and 3D measurements (Pearson's r between 0.43 and 0.97, p < 0.05). Left atrial volume (LAV) also correlated significantly although LHM did estimate larger LAV compared to both 2DE and 3DE (Pearson's r between 0.61 and 0.81, p < 0.01). The fully automated software works well in a real-world setting and helps to overcome some of the major hurdles in integrating 3D analysis into daily practice, as it is user-independent and highly reproducible in a group of patients with a clearly defined and well-studied valvular abnormality.


Subject(s)
Aortic Valve/abnormalities , Echocardiography, Three-Dimensional , Heart Atria/diagnostic imaging , Heart Valve Diseases/diagnostic imaging , Heart Ventricles/diagnostic imaging , Image Interpretation, Computer-Assisted/methods , Models, Cardiovascular , Patient-Specific Modeling , Software Validation , Adult , Aortic Valve/diagnostic imaging , Aortic Valve/physiopathology , Atrial Function, Left , Automation , Bicuspid Aortic Valve Disease , Feasibility Studies , Female , Heart Atria/physiopathology , Heart Valve Diseases/physiopathology , Heart Ventricles/physiopathology , Humans , Male , Predictive Value of Tests , Prospective Studies , Stroke Volume , Tomography, X-Ray Computed , Ventricular Function, Left , Young Adult
17.
Eur Radiol ; 27(9): 3618-3624, 2017 Sep.
Article in English | MEDLINE | ID: mdl-28127643

ABSTRACT

OBJECTIVES: The purpose of this study was to assess the efficacy of the renewed dynamic collimator in a third-generation dual source CT (DSCT) scanner and to determine the improvements over the second-generation scanner. METHODS: Collimator efficacy is defined as the percentage overranging dose in terms of dose-length product (DLP) that is blocked by the dynamic collimator relative to the total overranging dose in case of a static collimator. Efficacy was assessed at various pitch values and different scan lengths. The number of additional rotations due to overranging and effective scan length were calculated on the basis of reported scanning parameters. On the basis of these values, the efficacy of the collimator was calculated. RESULTS: The second-generation scanner showed decreased performance of the dynamic collimator at increasing pitch. Efficacy dropped to 10% at the highest pitch. For the third-generation scanner the efficacy remained above 50% at higher pitch. Noise was for some pitch values slightly higher at the edge of the imaged volume, indicating a reduced scan range to reduce the overranging dose. CONCLUSIONS: The improved dynamic collimator in the third-generation scanner blocks the overranging dose for more than 50% and is more capable of shielding radiation dose, especially in high pitch scan modes. KEY POINTS: • Overranging dose is to a large extent blocked by the dynamic collimator • Efficacy is strongly improved within the third-generation DSCT scanner • Reducing the number of additional rotations can reduce overranging with increased noise.


Subject(s)
Radiation Dosage , Tomography, Spiral Computed/instrumentation , Tomography, Spiral Computed/methods , Equipment Design , Humans , Image Processing, Computer-Assisted/methods , Phantoms, Imaging , Radiation Protection/methods
18.
JACC Cardiovasc Imaging ; 10(7): 760-770, 2017 07.
Article in English | MEDLINE | ID: mdl-28109933

ABSTRACT

OBJECTIVES: The aim of this study was to investigate the individual and combined accuracy of dynamic computed tomography (CT) myocardial perfusion imaging (MPI) and computed tomography angiography (CTA) fractional flow reserve (FFR) for the identification of functionally relevant coronary artery disease (CAD). BACKGROUND: Coronary CTA has become an established diagnostic test for ruling out CAD, but it does not allow interpretation of the hemodynamic severity of stenotic lesions. Two recently introduced functional CT techniques are dynamic MPI and CTA FFR using computational fluid dynamics. METHODS: From 2 institutions, 74 patients (n = 62 men, mean age 61 years) planned for invasive angiography with invasive FFR measurement in 142 vessels underwent CTA imaging and dynamic CT MPI during adenosine vasodilation. A patient-specific myocardial blood flow index was calculated, normalized to remote myocardial global left ventricular blood flow. CTA FFR was computed using an on-site, clinician-operated application. Using binary regression, a single functional CT variable was created combining both CT MPI and CTA FFR. Finally, stepwise diagnostic work-up of CTA FFR with selective use of CT MPI was simulated. The diagnostic performance of CT MPI, CTA FFR, and CT MPI integrated with CTA FFR was evaluated using C statistics with invasive FFR, with a threshold of 0.80 as a reference. RESULTS: Sensitivity, specificity, and accuracy were 73% (95% confidence interval [CI]: 61% to 86%), 68% (95% CI: 56% to 80%), and 70% (95% CI: 62% to 79%) for CT MPI and 82% (95% CI: 72% to 92%), 60% (95% CI: 48% to 72%), and 70% (63% to 80%) for CTA FFR. For CT MPI integrated with CTA FFR, diagnostic accuracy was 79% (95% CI: 71% to 87%), with improvement of the area under the curve from 0.78 to 0.85 (p < 0.05). Accuracy of the stepwise approach was 77%. CONCLUSIONS: CT MPI and CTA FFR both identify functionally significant CAD, with comparable accuracy. Diagnostic performance can be improved by combining the techniques. A stepwise approach, reserving CT MPI for intermediate CTA FFR results, also improves diagnostic performance while omitting nearly one-half of the population from CT MPI examinations.


Subject(s)
Computed Tomography Angiography/methods , Coronary Angiography/methods , Coronary Artery Disease/diagnostic imaging , Coronary Vessels/diagnostic imaging , Fractional Flow Reserve, Myocardial , Myocardial Perfusion Imaging/methods , Adenosine/administration & dosage , Aged , Area Under Curve , Coronary Artery Disease/physiopathology , Coronary Vessels/physiopathology , Female , Humans , London , Male , Middle Aged , Models, Cardiovascular , Netherlands , Predictive Value of Tests , ROC Curve , Radiographic Image Interpretation, Computer-Assisted , Reproducibility of Results , Vasodilator Agents/administration & dosage
19.
Eur Radiol ; 27(6): 2309-2316, 2017 Jun.
Article in English | MEDLINE | ID: mdl-27704198

ABSTRACT

OBJECTIVES: To investigate the additional value of transmural perfusion ratio (TPR) in dynamic CT myocardial perfusion imaging for detection of haemodynamically significant coronary artery disease compared with fractional flow reserve (FFR). METHODS: Subjects with suspected or known coronary artery disease were prospectively included and underwent a CT-MPI examination. From the CT-MPI time-point data absolute myocardial blood flow (MBF) values were temporally resolved using a hybrid deconvolution model. An absolute MBF value was measured in the suspected perfusion defect. TPR was defined as the ratio between the subendocardial and subepicardial MBF. TPR and MBF results were compared with invasive FFR using a threshold of 0.80. RESULTS: Forty-three patients and 94 territories were analysed. The area under the receiver operator curve was larger for MBF (0.78) compared with TPR (0.65, P = 0.026). No significant differences were found in diagnostic classification between MBF and TPR with a territory-based accuracy of 77 % (67-86 %) for MBF compared with 70 % (60-81 %) for TPR. Combined MBF and TPR classification did not improve the diagnostic classification. CONCLUSIONS: Dynamic CT-MPI-based transmural perfusion ratio predicts haemodynamically significant coronary artery disease. However, diagnostic performance of dynamic CT-MPI-derived TPR is inferior to quantified MBF and has limited incremental value. KEY POINTS: • The transmural perfusion ratio from dynamic CT-MPI predicts functional obstructive coronary artery disease • Performance of the transmural perfusion ratio is inferior to quantified myocardial blood flow • The incremental value of the transmural perfusion ratio is limited.


Subject(s)
Coronary Stenosis/diagnostic imaging , Hemodynamics/physiology , Myocardial Perfusion Imaging/methods , Aged , Coronary Angiography/methods , Coronary Artery Disease/diagnostic imaging , Coronary Stenosis/physiopathology , Female , Humans , Male , Middle Aged , Prospective Studies , Severity of Illness Index , Tomography, X-Ray Computed/methods
20.
J Clin Imaging Sci ; 6: 44, 2016.
Article in English | MEDLINE | ID: mdl-27833784

ABSTRACT

PURPOSE: This study aims to compare image quality, radiation dose, and the influence of the heart rate on image quality of high-pitch spiral coronary computed tomography angiography (CCTA) using 128-slice (second generation) dual-source CT (DSCT) and a 192-slice DSCT (third generation) scanner. MATERIALS AND METHODS: Two consecutive cohorts of fifty patients underwent CCTA by high-pitch spiral scan mode using 128 or 192-slice DSCT. The 192-slice DSCT system has a more powerful roentgen tube (2 × 120 kW) that allows CCTA acquisition at lower tube voltages, wider longitudinal coverage for faster table speed (732 m/s), and the use of iterative reconstruction. Objective image quality was measured as the signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR). Subjective image quality was evaluated using a Likert scale. RESULTS: While the effective dose was lower with 192-slice DSCT (1.2 ± 0.5 vs. 0.6 ± 0.3 mSv; P < 0.001), the SNR (18.9 ± 4.3 vs. 11.0 ± 2.9; P < 0.001) and CNR (23.5 ± 4.8 vs. 14.3 ± 4.1; P < 0.001) were superior to 128-slice DSCT. Although patients scanned with 192-slice DSCT had a faster heart rate (59 ± 7 vs. 56 ± 6; P = 0.045), subjective image quality was scored higher (4.2 ± 0.8 vs. 3.0 ± 0.7; P < 0.001) compared to 128-slice DSCT. CONCLUSIONS: High-pitch spiral CCTA by 192-slice DSCT provides better image quality, despite a higher average heart rate, at lower radiation doses compared to 128-slice DSCT.

SELECTION OF CITATIONS
SEARCH DETAIL
...