Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Rapid Commun Mass Spectrom ; 28(11): 1293-302, 2014 Jun 15.
Article in English | MEDLINE | ID: mdl-24760570

ABSTRACT

RATIONALE: Improvements in the design of low-flow highly sensitive chromatographic ion source interfaces allow the detection and characterisation of drugs and metabolites from smaller sample volumes. This in turn improves the ethical treatment of animals by reducing both the number of animals needed and the blood sampling volumes required. METHODS: A new microfluidic device combining an ultra-high pressure liquid chromatography (UHPLC) analytical column with a nano-flow electrospray source is described. All microfluidic, gas and electrical connections are automatically engaged when the ceramic microfluidic device is inserted into the source enclosure. The system was used in conjunction with a hybrid quadrupole-time-of-flight mass spectrometer. RESULTS: The improved sensitivity of the system is highlighted in its application in the quantification and qualification of midazolam and its metabolites detected in whole blood from chimeric and wild-type mice. Metabolite identification and full pharmacokinetic profiles were obtained from a single micro-litre of whole blood at each sampling time and significant pharmacokinetic differences were observed between the two types of mice. CONCLUSIONS: Improvements in the enhanced ionisation efficiency from the microfluidic device in conjunction with nanoUHPLC/MS was sufficiently sensitive for the identification and quantification of midazolam metabolites from a single micro-litre of whole blood. Detection of metabolites not previously recorded from the chimeric mouse in vivo model was made.


Subject(s)
Microfluidic Analytical Techniques/methods , Midazolam/blood , Midazolam/chemistry , Animals , Chromatography, High Pressure Liquid , Mice , Midazolam/pharmacokinetics , Molecular Structure , Spectrometry, Mass, Electrospray Ionization
2.
Analyst ; 135(2): 306-14, 2010 Feb.
Article in English | MEDLINE | ID: mdl-20098763

ABSTRACT

An electrospray ionisation triple quadrupole mass spectrometer (Varian 1200 L) was modified to accept nitrogen samples containing low concentrations of volatile organic compounds. Six candidate probe compounds, methyl decanoate, octan-3-one, 2-ethylhexanoic acid, 1,4-diaminobutane, dimethyl methylphosphonate, and 2,3-butanediol, at concentrations below 50 ppb(v) were generated with permeation tubes in a test atmosphere generator. The concept of using a set of molecular probes to evaluate gas-phase electrospray ionisation of volatile analytes was assessed and the feasibility of adopting a unified ionisation approach for gas and liquid contamination of exobiotic environments established. 450 experiments were run in a five-replicate, fifteen-level, three-factor, central-composite-design with exponential dilution for each of the six probe compounds studied. The three factors studied were ionisation voltage, drying-gas flow and nebulising-gas flow. Parametric modelling by regression analysis enabled the differences in the ionisation behaviours of the probe compounds to be described by the optimisation models. Regression coefficients were in the range 0.91 to 0.99, indicating satisfactory levels of precision in the optimisation models. A wide range in ionisation efficiency was observed, with different optimised conditions required for the probe compounds. It was evident that no one factor appeared to dominate the response and the different factors produced different effects on the responses for the different molecules. 1,4-Butanediamine and dimethyl methylphosphonate required significantly lower ionisation voltages (1.2 kV) than the other four, which achieved optimised sensitivity towards the maximum voltage used in this design (5 to 6 kV). Drying-gas flow rates were found to be more important than nebulising-gas flow rates. However, variations in the constant term B(0) in the optimisation models indicated that other factors, not included in this study, were also likely to be involved in the ionisation process. Electrolyte-flow rate and ionisation temperature were proposed for follow up studies. Exponential dilution data indicated sensitive and analytically useful responses in the target range of 5 to 50 ppb(v) for all six compounds. Significantly, responses were seen at concentrations significantly below 5 ppb(v), with sub ppt(v) responses observed for 1,4-butanediamine, 2-ethylhexanoic acid, dimethylmethylphosphonate, and 1,3-butanediol. Responses in the ppt(v) to ppb(v) range were observed for the remaining two compounds. The observations from this study demonstrated the utility of adopting a set of probe compounds to evaluate electrospray ionisation performance for volatile organic compound based assays; indicated the existence of multiple ionisation mechanisms; and revealed potential sensitivity at the parts per quadrillion level ppq(v).

3.
J Chromatogr A ; 1155(2): 199-205, 2007 Jul 06.
Article in English | MEDLINE | ID: mdl-17229431

ABSTRACT

An injection moulded free flow isotachophoresis (FFITP) microdevice with integrated carbon fibre loaded electrodes with a separation chamber of 36.4mm wide, 28.7 mm long and 100 microm deep is presented. The microdevice was completely fabricated by injection moulding in carbon fibre loaded polystyrene for the electrodes and crystal polystyrene for the remainder of the chip and was bonded together using ultrasonic welding. Two injection moulded electrode designs were compared, one with the electrode surface level with the separation chamber and one with a recessed electrode. Separations of two anionic dyes, 0.2mM each of amaranth and acid green and separations of 0.2mM each of amaranth, bromophenol blue and glutamate were performed on the microdevice. Flow rates of 1.25 ml min(-1) for the leading and terminating electrolytes were used and a flow rate of 0.63 ml min(-1) for the sample. Electric fields of up to 370 V cm(-1) were applied across the separation chamber. Joule heating was not found to be significant although out-gassing was observed at drive currents greater than 3 mA.


Subject(s)
Electrophoresis/instrumentation , Electrophoresis/methods , Electrodes , Equipment Design/instrumentation , Equipment Design/methods , Miniaturization
SELECTION OF CITATIONS
SEARCH DETAIL
...