Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Nat Commun ; 14(1): 6750, 2023 10 27.
Article in English | MEDLINE | ID: mdl-37891183

ABSTRACT

A positron emission tomography (PET) tracer detecting α-synuclein pathology will improve the diagnosis, and ultimately the treatment of α-synuclein-related diseases. Here we show that the PET ligand, [18F]ACI-12589, displays good in vitro affinity and specificity for pathological α-synuclein in tissues from patients with different α-synuclein-related disorders including Parkinson's disease (PD) and Multiple-System Atrophy (MSA) using autoradiography and radiobinding techniques. In the initial clinical evaluation we include 23 participants with α-synuclein related disorders, 11 with other neurodegenerative disorders and eight controls. In vivo [18F]ACI-12589 demonstrates clear binding in the cerebellar white matter and middle cerebellar peduncles of MSA patients, regions known to be highly affected by α-synuclein pathology, but shows limited binding in PD. The binding statistically separates MSA patients from healthy controls and subjects with other neurodegenerative disorders, including other synucleinopathies. Our results indicate that α-synuclein pathology in MSA can be identified using [18F]ACI-12589 PET imaging, potentially improving the diagnostic work-up of MSA and allowing for detection of drug target engagement in vivo of novel α-synuclein targeting therapies.


Subject(s)
Multiple System Atrophy , Parkinson Disease , Humans , alpha-Synuclein/metabolism , Multiple System Atrophy/metabolism , Parkinson Disease/metabolism , Positron-Emission Tomography
2.
Anal Bioanal Chem ; 397(6): 2245-52, 2010 Jul.
Article in English | MEDLINE | ID: mdl-20437228

ABSTRACT

Anatoxin-a is a potent alkaloid neurotoxin produced by a number of cyanobacterial species and released in freshwaters during cyanobacterial blooms. Its high toxicity is responsible for several incidents of lethal intoxications of birds and mammals around the world; therefore anatoxin-a has to be regarded as a health risk and its concentration in lakes and water reservoirs should be monitored. Phenylalanine is a natural amino acid, also present in freshwaters, isobaric to anatoxin-a, with a very similar fragmentation pattern and LC retention. Since misidentification of phenylalanine as anatoxin-a has been reported in forensic investigations, special care must be taken in order to selectively determine traces of anatoxin-a in the presence of naturally occurring phenylalanine. A fast LC tandem MS method was developed by using a 1.8 microm 50 x 2.1 mm C18 column for the separation of anatoxin-a and phenylalanine, achieving a 3-min analysis time. Isotopically labelled phenylalanine-d(5) was employed as internal standard to compensate for electrospray ion suppression and sample preconcentration losses. Both compounds were preconcentrated 1,000-fold on a porous graphitic carbon solid-phase extraction (SPE) cartridge after adjustment of sample pH to 10.5. The method was validated by using lake water spiked at four different levels from 0.01 to 1 microg L(-1). Anatoxin-a recovery ranged from 73 to 97%, intra-day precision (RSD%) ranged from 4.2 to 5.9, while inter-day precision (RSD%) ranged from 4.2 to 9.1%. Limits of detection and quantification were 0.65 and 1.96 ng L(-1) respectively. The method was successfully applied for the detection of anatoxin-a in Greek lakes at concentrations ranging from less than 0.6 to 9.1 ng L(-1).


Subject(s)
Fresh Water/analysis , Tropanes/analysis , Bacterial Toxins/analysis , Chromatography, Liquid/methods , Chromatography, Liquid/standards , Cyanobacteria Toxins , Greece , Limit of Detection , Marine Toxins , Methods , Phenylalanine , Reproducibility of Results , Solid Phase Extraction/methods , Tandem Mass Spectrometry/methods , Tandem Mass Spectrometry/standards
3.
J Chromatogr A ; 1217(22): 3619-27, 2010 May 28.
Article in English | MEDLINE | ID: mdl-20399436

ABSTRACT

This paper presents the application of ion chromatography with electrolytic eluent generation and mobile phase suppression for the direct conductimetric detection of glyphosate and its degradation product aminomethylphosphonic acid (AMPA). The compounds were separated on a Dionex AS18 anion exchange column with a 12-40 mM KOH step gradient from 9 to 9.5 min. The effect of the suppressor current intensity on the electrostatic interaction of these amphoteric compounds with the suppressor cation exchange membranes was evaluated. A suppressor current gradient technique was proposed for the limitation of peak broadening and baseline noise, in order to improve method sensitivity and detectability. It was observed that residual sample carbonates co-eluted with AMPA when a large injection loop was installed for the low level determination of both compounds in natural waters. For this reason, glyphosate was isocratically eluted using 33 mM KOH in order to decrease analysis time within 10 min and a column clean up step using 100 mM KOH was used to ensure retention time reproducibility. The developed method was applied to the analysis of drinking and natural water and it was further successfully applied to orange samples with slight modifications. Instrumental LOD for glyphosate was 0.24 microg/L, while method LOD was 0.54 microg/L for spring waters and 0.01 mg/kg for oranges using a 1000 microL direct loop injection of the sample. Intra-day and inter-day precision (as %RSD) for water samples was 4.6% and 12% at a spiking level of 2 microg/L, and the recovery ranged from 64% to 88% depending on sample conductivity. For orange samples, the inter-day precision was 1.4% at a spiking level of 4.4 mg/kg, while overall recovery was 103%. The developed method is direct, fast, sensitive and relatively inexpensive, and could be used as an ideal fast screening tool for the monitoring of glyphosate residues in water and fruit samples.


Subject(s)
Chromatography, Ion Exchange/methods , Glycine/analogs & derivatives , Organophosphonates/analysis , Pesticides/analysis , Citrus sinensis/chemistry , Food Analysis/methods , Glycine/analysis , Glycine/chemistry , Isoxazoles , Linear Models , Organophosphonates/chemistry , Pesticides/chemistry , Reproducibility of Results , Sensitivity and Specificity , Tetrazoles , Water/chemistry , Water Pollutants, Chemical/analysis , Water Pollutants, Chemical/chemistry , Glyphosate
SELECTION OF CITATIONS
SEARCH DETAIL
...