1.
Yao Xue Xue Bao ; 45(1): 87-92, 2010 Jan.
Article in Chinese | MEDLINE | ID: mdl-21351455

ABSTRACT

To establish a sensitive and specific method for simultaneous determination of gestodene, etonogestrel and ethinylestradiol in plasma by LC-MS/MS, plasma samples were extracted and derivatized before injection. An ESI ion source was used and operated in the positive ion mode with multiple reaction monitoring (MRM). Norgestrel was chosen as internal standard and performed on a C18 (100 mm x 2.1 mm, 5 microm) column. The concentrations of gestodene, etonogestrel and ethinylestradiol were measured, using step-gradient mobile phase and step-gradient flow rate. The method was validated over the concentration range of 0.1-20 ng x mL(-1) for gestodene and etonogestrel and 0.01-2 ng x mL(-1) for ethinylestradiol, and showed excellent linearity. The intra- and inter-assay accuracy and precision were below 10.0% and recovery was 93.6%-110.9% over the three concentration levels evaluated. The method was applied in pharmacokinetic study of the compound gestodene patch and the compound etonogestrel patch in rabbits. The LC-MS/MS method was selective, accurate and sensitive, especially the LOQ were 100 pg x mL(-1) for gestodene and etonogestrel and 10 pg x mL(-1) for ethinylestradiol. The method was successfully applied in pharmacokinetic study for contraceptives.


Subject(s)
Desogestrel/blood , Ethinyl Estradiol/blood , Norpregnenes/blood , Animals , Chromatography, Liquid , Desogestrel/pharmacokinetics , Ethinyl Estradiol/pharmacokinetics , Norpregnenes/pharmacokinetics , Rabbits , Sensitivity and Specificity , Spectrometry, Mass, Electrospray Ionization
2.
Biomed Chromatogr ; 21(2): 132-8, 2007 Feb.
Article in English | MEDLINE | ID: mdl-17221919

ABSTRACT

A method has been developed for the simultaneous quantification of metformin (I) and glipizide (II) in human plasma. It is based on high-performance liquid chromatography with electrospray ionization tandem mass (LC-ESI-MS/MS) spectrometric detection in positive ionization mode. Phenformin (III) and gliclazide (IV) were used as internal standards for I and II, respectively. The MS/MS detection was performed in multiple reaction monitoring (MRM) mode. The precursor-product ion combinations of m/z 130 --> 71, 446 --> 321, 206 --> 60 and 324 --> 127 were used to quantify I, II, III and IV, respectively. This method was validated in the concentration ranges of 0.02-4 microg/mL for I and 0.004-0.8 microg/mL for II. It was utilized to support a clinical pharmacokinetic study after single dose oral administration of a combination of I and II.


Subject(s)
Chromatography, High Pressure Liquid/methods , Glipizide/blood , Metformin/blood , Spectrometry, Mass, Electrospray Ionization/methods , Tandem Mass Spectrometry/methods , Drug Stability , Glipizide/pharmacokinetics , Humans , Male , Metformin/pharmacokinetics , Reproducibility of Results , Sensitivity and Specificity