Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
Am J Emerg Med ; 47: 347.e1-347.e3, 2021 09.
Article in English | MEDLINE | ID: mdl-33745773

ABSTRACT

Blunt cerebrovascular injury is a very rare complication of blunt trauma and a diagnostic challenge. A 14 year old male fell 10 m sustaining multi system trauma. The atypical Glasgow Coma Score was six with a fully preserved eye component. Initial whole-body CT scanning demonstrated multiple injuries but no obvious brain injury. Trauma management involved non-operative resuscitation and was successful, however profound coma occurred and brain stem reflexes disappeared on day two. Repeat brain CT scan demonstrated multiple cerebral and cerebellar ischemic lesions and no opacification of the vertebral or basilar arteries. Secondary analysis of the first CT scan demonstrated a small focal basilar artery dissection not initially reported. Our case report highlights an unusual cause of coma after traumatic brain injury where the clinical scenario mimics locked in syndrome. In such circumstances cerebrovascular injury, and in particular traumatic basilar artery dissection, must be actively excluded.


Subject(s)
Basilar Artery/injuries , Wounds, Nonpenetrating/complications , Adolescent , Aortic Dissection/diagnosis , Basilar Artery/diagnostic imaging , Basilar Artery/pathology , Brain Injuries, Traumatic/diagnostic imaging , Brain Injuries, Traumatic/etiology , Glasgow Coma Scale , Humans , Male
2.
Aliment Pharmacol Ther ; 47(5): 621-630, 2018 03.
Article in English | MEDLINE | ID: mdl-29322599

ABSTRACT

BACKGROUND: Two algorithms based on sequential measurements of liver and spleen stiffness using two-dimensional shearwave elastography (2D-SWE) have been recently proposed to estimate clinically significant portal hypertension (hepatic venous pressure gradient [HVPG] ≥10 mm Hg) in patients with cirrhosis, with excellent diagnostic accuracy. AIM: To validate externally these algorithms in a large cohort of patients with cirrhosis. METHODS: One hundred and ninety-one patients with stable cirrhosis (Child-Pugh class A 39%, B 29% and C 31%) who underwent liver and spleen stiffness measurements using 2D-SWE at the time of HVPG measurement were included. Diagnostic accuracy of the 2 algorithms was assessed by calculating sensitivity, specificity, positive and negative predictive values. RESULTS: The first algorithm, using liver stiffness <16.0 kilopascals (kPa) and then spleen stiffness <26.6 kPa, was used to rule-out HVPG ≥10 mm Hg. In our population, its sensitivity and negative predictive value were 95% and 63% respectively. The second algorithm, using liver stiffness >38.0 kPa, or liver stiffness ≤38.0 kPa but spleen stiffness >27.9 kPa, was used to rule-in HVPG ≥10 mm Hg. In our population, its specificity and positive predictive value were 52% and 83% respectively. Restricting the analyses to the 74 patients without any history of decompensation of cirrhosis or to the 65 patients with highly reliable liver stiffness measurement did not improve the results. CONCLUSION: In our population, diagnostic accuracies of non-invasive algorithms based on sequential measurements of liver and spleen stiffness using 2D-SWE were acceptable, but not good enough to replace HVPG measurement or to base clinical decisions.


Subject(s)
Algorithms , Elasticity Imaging Techniques , Hypertension, Portal/diagnosis , Liver Cirrhosis/diagnosis , Liver/diagnostic imaging , Spleen/diagnostic imaging , Aged , Elasticity Imaging Techniques/methods , Female , Hardness/physiology , Humans , Hypertension, Portal/complications , Liver/pathology , Liver Cirrhosis/complications , Male , Middle Aged , Portal Pressure , Reproducibility of Results , Sensitivity and Specificity , Spleen/pathology
3.
Abdom Radiol (NY) ; 41(2): 283-94, 2016 Feb.
Article in English | MEDLINE | ID: mdl-26867910

ABSTRACT

Despite advances in multimodality imaging of pancreas, there is still overlap between imaging findings of several pancreatic/peripancreatic disease processes. Pancreatic and peripancreatic non-neoplastic entities may mimic primary pancreatic neoplasms on ultrasound, CT, and MRI. On the other hand, primary pancreatic cancer may be overlooked on imaging because of technical and inherent factors. The purpose of this pictorial review is to describe and illustrate pancreatic imaging pitfalls and highlight the basic radiological features for proper differential diagnosis.


Subject(s)
Multimodal Imaging , Pancreatic Diseases/diagnostic imaging , Diagnosis, Differential , Humans , Pancreatic Neoplasms/diagnostic imaging
SELECTION OF CITATIONS
SEARCH DETAIL
...