Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
J Acad Ophthalmol (2017) ; 15(2): e261-e270, 2023 Jul.
Article in English | MEDLINE | ID: mdl-38059190

ABSTRACT

Background The evolution of medical school curricula, characterized by truncated preclinical periods and reduced emphasis on ophthalmology, presents formidable obstacles to early exposure for aspiring medical students. The constraints imposed by the coronavirus disease 2019 pandemic further exacerbated the limitations on opportunities, compelling the implementation of innovative initiatives aimed at augmenting students' ophthalmology education through virtual means. Purpose This article assesses the impact of an Ophthalmology Virtual Externship (OVE) on medical students' knowledge, interest, confidence, and seeking mentorship in ophthalmology. Materials and Methods A total of 76 students voluntarily participated in the program. The OVE encompassed four virtual sessions, facilitated by 4th year medical students employing a near-peer mentorship framework. The initiative was tailored for 2nd and 3rd year medical students and was conducted under the supervision of a faculty member. All participating students completed both pre- and postexternship surveys utilizing a 7-point Likert scale to gauge their levels of interest, confidence, and inclination toward mentorship opportunities in the field of ophthalmology. Furthermore, assessments of ophthalmology knowledge were administered prior to and subsequent to the externship participation. The degree of satisfaction derived from the OVE experience was also evaluated. Results Participation in the OVE significantly elevated confidence in knowledge ( p < 0.001) and mentorship interest ( p = 0.029). Ophthalmology knowledge test scores also notably improved post-OVE across all participants, irrespective of prior experience ( p < 0.001), with the most significant increase observed among 2nd and 3rd year students ( p < 0.0001). After OVE participation, 73% of students expressed intent to pursue ophthalmology opportunities, including mentorship or research. The OVE received an average Likert score of 6.35 out of 7 for student satisfaction. Conclusion The OVE serves as a virtual learning instrument beneficial for 2nd and 3rd year students with a proclivity for ophthalmology, offering a means to circumvent curriculum-related constraints. Moreover, given the decline in formal ophthalmic education, our study contributes to future research assessing the effectiveness of an OVE in addressing ophthalmic knowledge gaps among all medical students.

2.
BMJ Case Rep ; 16(11)2023 Nov 30.
Article in English | MEDLINE | ID: mdl-38035676

ABSTRACT

Posterior reversible encephalopathy syndrome (PRES) is characterised by encephalopathy, visual disturbances and seizures, accompanied by radiological parieto-occipital oedema. Immunosuppressive and immunomodulatory drugs are risk factors. While capecitabine-induced PRES cases are rare, this report details a young woman with advanced gastric adenocarcinoma on capecitabine. She exhibited symptoms of nausea, vomiting and abdominal pain before developing hypertension, drowsiness and a seizure. Brain MRI revealed parieto-occipital hyperintense areas indicative of PRES. Suspending capecitabine led to a gradually improved mental state. Prompt recognition and treatment of PRES offer reversibility, often achievable through dose reduction or discontinuation of the causative drug.


Subject(s)
Adenocarcinoma , Brain Diseases , Posterior Leukoencephalopathy Syndrome , Stomach Neoplasms , Female , Humans , Posterior Leukoencephalopathy Syndrome/chemically induced , Posterior Leukoencephalopathy Syndrome/diagnostic imaging , Capecitabine/adverse effects , Brain Diseases/complications , Magnetic Resonance Imaging , Seizures/complications , Stomach Neoplasms/drug therapy , Stomach Neoplasms/complications , Adenocarcinoma/complications
3.
Curr Probl Cardiol ; 48(4): 101557, 2023 Apr.
Article in English | MEDLINE | ID: mdl-36528205

ABSTRACT

Since its Food and Drug Administration approval in January 2007, the Angiosculpt scoring balloon catheter has been widely utilized in severely calcified stenotic vascular lesions. We sought to characterize the complication rates, failure modes, and outcomes associated with the Angiosculpt catheter. Using queried events from October 2013 to December 2020 from the Food and Drug Administration Manufacturer and User Facility Device Experience database, we analyzed the Angiosculpt scoring balloon catheter complication rates and mode of failure. A total of 248 complications were reported. Most reported complications occurred in the superficial femoral artery (SFA) (19.4%, n = 48), followed by the left anterior descending artery (8.1%, n = 20). Severe vessel calcifications were reported in (26.6%, n = 66) of the complications. Most complications occurred with damage to the device, such as tip break (44.8%, n = 111) and balloon rupture (26.6%, n = 66). Some complications were due to difficulties in the withdrawal of the catheter (23.8%, n = 59). Balloon rupture is observed at a significantly higher rate amongst calcified vessels (60.6% vs 14.8%), P = < 0.001, and in cases involving the SFA (39.4% vs 11.3%), P = < 0.001. All-cause complications in calcified vessels are associated with the SFA (39.4% vs 12.5%), P = < 0.001, and left anterior descending artery (16.7% vs 5.1%), P = < 0.001. The Angiosculpt scoring balloon catheter has a relatively low complication rate. Most complications were associated with a device tip break, balloon rupture, and difficulties in withdrawal in severely calcified vessels.


Subject(s)
Catheters , Coronary Vessels , Humans , Treatment Outcome
4.
J Am Soc Echocardiogr ; 36(5): 490-499, 2023 05.
Article in English | MEDLINE | ID: mdl-36442765

ABSTRACT

BACKGROUND: The extent of diastolic dysfunction is of clinical importance in the risk stratification and management of patients with Takotsubo cardiomyopathy (TC). Standard echocardiographic indices of diastolic dysfunction have robust predictive ability in assorted disease states, but have not been validated in TC. The aim of this study was to compare Doppler metrics of diastolic function against catheterization-measured filling pressures in TC. METHODS: Patients with TC who met inclusion and exclusion criteria were evaluated using echocardiography and catheterization performed within 24 hours. Both left ventricular (LV) end-diastolic pressure and LV pre-A diastolic pressure were obtained from catheterization tracings. The echocardiographic parameters for diastolic function were extracted using the American Society of Echocardiography recommendations and a previously validated regression equation for mean left atrial pressure (mLAP). RESULTS: A total of 51 patients with TC were included. Patients were predominantly women (72.5%), with a mean age of 58 ± 13 years and a mean ejection fraction of 24 ± 10 %. E/e' ratio (septal, average, and lateral) and calculated mLAP correlated positively with catheterization LV pre-A, with fair to moderate correlation (coefficient range, 0.38-0.44). The t-test mean difference between LV pre-A pressure and calculated mLAP was 0.77 ± 7.34 mm Hg (95% CI, ±14.68 mm Hg) suggesting inconsistent measures. mLAP also exhibited poor diagnostic ability to discriminate elevated LV pre-A diastolic pressure, with an area under the receiver operating characteristic curve of 0.69 (95% CI, 0.50-0.88). CONCLUSIONS: Commonly used echocardiographic parameters for diastolic function demonstrated less-than-optimal correlation, with poor sensitivity and specificity, compared with invasively measured LV end-diastolic pressure or LV pre-A wave diastolic pressure in patients with TC. Precise characterization of LV filling pressure in patients with TC using contemporary noninvasive echocardiographic parameters appears challenging. Invasive measurements of filling pressure should remain the gold standard for optimal risk stratification and management of patients with TC.


Subject(s)
Takotsubo Cardiomyopathy , Ventricular Dysfunction, Left , Humans , Female , Middle Aged , Aged , Male , Echocardiography, Doppler , Takotsubo Cardiomyopathy/diagnosis , Takotsubo Cardiomyopathy/diagnostic imaging , Echocardiography , Sensitivity and Specificity , ROC Curve , Diastole , Ventricular Dysfunction, Left/diagnostic imaging , Ventricular Dysfunction, Left/etiology , Ventricular Function, Left , Ventricular Pressure
SELECTION OF CITATIONS