Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Appl Opt ; 57(20): 5779-5783, 2018 Jul 10.
Article in English | MEDLINE | ID: mdl-30118047

ABSTRACT

Electrically actuated shape memory alloys (SMAs) find widespread applications in engineering and science. Such materials are known to retain/remember their state. In the stressed/deformed state, when activated by the application of a suitable excitation mechanism, such as the use of heat or potential, they return to their original unstressed state. To test their reliability, it is a standard procedure to undertake a life cycle analysis. In this paper, the life cycle analysis of a SMA spring using the Talbot interferometric technique is reported. The life cycle of the SMA spring is analyzed in terms of the displacement drift, which sets in because of the functional fatigue generated due to its repeated use. Collimated light from a He-Ne laser transmitted through a beam splitter is converged through a focusing lens onto a plane mirror attached to the spring. Backreflected light from the mirror is incident on a set of two Ronchi gratings separated by the Talbot distance, forming a moiré pattern. The resulting interferograms are analyzed using a fringe rotation mechanism. The angle of orientation is a function of displacement drift. There is deterioration in the SMA property because of repeated cycles, and the spring loses its ability to return to its original unstretched position. The values of the displacement drift generated after 1, 1000, 2000, 3000, 4000, and 5000 such cycles as measured using a Talbot interferometer are 0, 0.875, 1.275, 1.459, 1.720, and 1.859 mm, respectively. It is observed that the SMA effect deteriorates as the number of stretching/contraction cycles increases. The uncertainty analysis is also reported. The expanded uncertainty was determined to be 201.61 µm.

2.
Appl Opt ; 53(31): 7534-9, 2014 Nov 01.
Article in English | MEDLINE | ID: mdl-25402921

ABSTRACT

A simple and robust method for introducing a phase-shifting test procedure in a wedge-plate shearing interferometer is proposed. The output of the wedge-plate lateral shearing interferometer (LSI) is superposed onto a sinusoidal grating, forming a moiré pattern. The in-plane translation of grating perpendicular to the grating lines is used for introducing a known amount of phase shifts in the interferometer. Direct measurement of phase using a four-step phase-shifting method is undertaken. The applicability of this devised phase-shifting wedge-plate LSI has been successfully tested for setting the collimation position of optical beams. Good accuracy and precision are achieved.

SELECTION OF CITATIONS
SEARCH DETAIL
...