1.
J Magn Reson ; 210(1): 126-32, 2011 May.
Article in English | MEDLINE | ID: mdl-21444227

ABSTRACT

The 275GHz electron-paramagnetic-resonance spectrometer we reported on in 2004 has been equipped with a new probe head, which contains a cavity especially designed for operation in continuous-wave mode. The sensitivity and signal stability that is achieved with this new probe head is illustrated with 275GHz continuous-wave spectra of a 1mM frozen solution of the complex Fe(III)-ethylenediamine tetra-acetic acid and of 10mM frozen solutions of the protein rubredoxin, which contains Fe(3+) in its active site, from three different organisms. The high quality of the spectra of the rubredoxins allows the determination of the zero-field-splitting parameters with an accuracy of 0.5GHz. The success of our approach results partially from the enhanced absolute sensitivity, which can be reached using a single-mode cavity. At least as important is the signal stability that we were able to achieve with the new probe head.


Subject(s)
Electron Spin Resonance Spectroscopy/methods , Ferrous Compounds/chemistry , Rubredoxins/chemistry , Anisotropy , Edetic Acid/chemistry , Electron Spin Resonance Spectroscopy/instrumentation , Equipment Design , Sensitivity and Specificity , Solutions/chemistry , Spin Labels
2.
J Magn Reson ; 173(1): 49-53, 2005 Mar.
Article in English | MEDLINE | ID: mdl-15705512

ABSTRACT

A pulsed ENDOR spectrometer operating at a microwave frequency of 275 GHz is described. The results demonstrate that this type of spectroscopy can now be performed routinely at this high microwave frequency. The advantages compared to conventional EPR frequencies are the high spectral resolution, time resolution, and sensitivity.

3.
J Magn Reson ; 166(1): 92-9, 2004 Jan.
Article in English | MEDLINE | ID: mdl-14675824

ABSTRACT

An electron paramagnetic resonance (EPR) spectrometer is described which allows for continuous-wave and pulsed EPR experiments at 275 GHz (wavelength 1.1 mm). The related magnetic field of 9.9 T for g approximately 2 is supplied by a superconducting solenoid. The microwave bridge employs quasi-optical as well as conventional waveguide components. A cylindrical, single-mode cavity provides a high filling factor and a high sensitivity for EPR detection. Even with the available microwave power of 1 mW incident at the cavity a high microwave magnetic field B1 is obtained of about 0.1 mT which permits pi/2-pulses as short as 100 ns. The performance of the spectrometer is illustrated with the help of spectra taken with several samples.


Subject(s)
Electron Spin Resonance Spectroscopy/instrumentation , Electron Spin Resonance Spectroscopy/methods , Microwaves , Signal Processing, Computer-Assisted/instrumentation , Carbon/chemistry , Equipment Design , Equipment Failure Analysis , Feasibility Studies , Freezing , Magnesium Oxide/chemistry , Reproducibility of Results , Sensitivity and Specificity , Zinc Oxide/chemistry