1.
ERJ Open Res ; 8(4)2022 Oct.
Article in English | MEDLINE | ID: mdl-36478916

ABSTRACT

Introduction: Objective cough frequency is a key clinical end-point but existing wearable monitors are limited to 24-h recordings. Albus Home uses contactless motion, acoustic and environmental sensors to monitor multiple metrics, including respiratory rate and cough without encroaching on patient lifestyle. The aim of this study was to evaluate measurement characteristics of nocturnal cough monitoring by Albus Home compared to manual counts. Methods: Adults with respiratory conditions underwent overnight monitoring using Albus Home in their usual bedroom environments. Participants set-up the plug-and-play device themselves. For reference counts, each audio recording was counted by two annotators, and cough defined as explosive phases audio-visually labelled by both. In parallel, recordings were processed by a proprietary Albus system, comprising a deep-learning algorithm with a human screening step for verifying or excluding occasional events that mimic cough. Performance of the Albus system in detecting individual cough events and reporting hourly cough counts was compared against reference counts. Results: 30 nights from 10 subjects comprised 375 hours of recording. Mean±sd coughs per night were 90±76. Coughs per hour ranged from 0 to 129. Albus counts were accurate across hours with high and low cough frequencies, with median sensitivity, specificity, positive predictive value and negative predictive values of 94.8, 100.0, 99.1 and 100.0%, respectively. Agreement between Albus and reference was strong (intra-class correlation coefficient (ICC) 0.99; 95% CI 0.99-0.99; p<0.001) and equivalent to agreement between observers and reference counts (ICC 0.98 and 0.99, respectively). Conclusions: Albus Home provides a unique, contactless and accurate system for cough monitoring, enabling collection of high-quality and potentially clinically relevant longitudinal data.

2.
Sensors (Basel) ; 22(19)2022 Sep 21.
Article in English | MEDLINE | ID: mdl-36236241

ABSTRACT

Respiratory rate (RR) is a clinically important predictor of cardio-respiratory deteriorations. The mainstay of clinical measurement comprises the manual counting of chest movements, which is variable between clinicians and limited to sporadic readings. Emerging solutions are limited by poor adherence and acceptability or are not clinically validated. Albus HomeTM is a contactless and automated bedside system for nocturnal respiratory monitoring that overcomes these limitations. This study aimed to validate the accuracy of Albus Home compared to gold standards in real-world sleeping environments. Participants undertook overnight monitoring simultaneously using Albus Home and gold-standard polygraphy with thoraco-abdominal respiratory effort belts (SomnomedicsEU). Reference RR readings were obtained by clinician-count of polygraphy data. For both the Albus system and reference, RRs were measured in 30-s segments, reported as breaths/minute, and compared. Accuracy was defined as the percentage of RRs from the Albus system within ±2 breaths/minute of reference counts. Across a diverse validation set of 32 participants, the mean accuracy exceeded 98% and was maintained across different participant characteristics. In a Bland-Altman analysis, Albus RRs had strong agreement with reference mean differences and the limits of agreement of -0.4 and ±1.2 breaths/minute, respectively. Albus Home is a contactless yet accurate system for automated respiratory monitoring. Validated against gold -standard methods, it enables long-term, reliable nocturnal monitoring without patient burden.


Subject(s)
Respiration , Respiratory Rate , Humans , Monitoring, Physiologic/methods
3.
ERJ Open Res ; 8(1)2022 Jan.
Article in English | MEDLINE | ID: mdl-35141315

ABSTRACT

The prototype ORACLE scale based on two simple measures of type 2 airway inflammation (blood eosinophils and F ENO) quantifies the excess risk conferred by raised biomarkers that is removed by type-2 anti-inflammatory treatment in trial populations https://bit.ly/3F1gnUl.

4.
Epilepsy Behav Rep ; 17: 100522, 2022.
Article in English | MEDLINE | ID: mdl-35036894