Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
Add more filters










Database
Publication year range
1.
Talanta ; 74(4): 717-23, 2008 Jan 15.
Article in English | MEDLINE | ID: mdl-18371699

ABSTRACT

Laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) was used to determine the distribution of the trace elements zinc, copper and lead in insular, central and hippocampal areas of thin tissue sections (thickness 20microm) through an entire human brain hemisphere. For the investigation of the tissue samples, a commercial laser ablation system was coupled to a double-focusing sector field ICP-MS. The regions of interest of healthy brain tissue (thickness 20microm) were scanned (raster area approximately 200mm(2)) with a focused laser beam (wavelength 266nm, diameter of laser crater 200microm and laser power density 3x10(9)Wcm(-2)). The ion intensities of (64)Zn(+), (63)Cu(+) and (208)Pb(+) were measured by LA-ICP-MS within the ablated area. For quantification purposes, matrix-matched laboratory standards were prepared by means of dosing of each analyte to the pieces of brain tissue. The mass spectrometric analysis yielded inhomogeneous and largely reciprocal distributions of Zn and Cu in the selected areas of investigated brain samples. The highest concentrations of Zn and Cu with the most distinct distribution pattern were found in the hippocampus (up to 15microg g(-1)). In contrast to zinc and copper, for lead, a more homogeneous distribution throughout all regions examined was found at a low concentration (in the ngg(-1) range) level within the analytical range of LA-ICP-MS.


Subject(s)
Copper/analysis , Hippocampus/chemistry , Lead/analysis , Mass Spectrometry/methods , Zinc/analysis , Aged , Female , Humans , Lasers , Reference Standards
2.
Article in English | MEDLINE | ID: mdl-17885277

ABSTRACT

Of all the inorganic mass spectrometric techniques, laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) plays a key role as a powerful and sensitive microanalytical technique enabling multi- element trace analysis and isotope ratio measurements at trace and ultratrace level. LA-ICP-MS was used to produce images of detailed regionally-specific element distribution in 20 microm thin sections of different parts of the human brain. The quantitative determination of copper, zinc, lead and uranium distribution in thin slices of human brain samples was performed using matrix-matched laboratory standards via external calibration procedures. Imaging mass spectrometry provides new information on the spatially inhomogeneous element distribution in thin sections of human tissues, for example, of different brain regions (the insular region) or brain tumor tissues. The detection limits obtained for Cu, Zn, Pb and U were in the ng g(-1) range. Possible strategies of LA-ICP-MS in brain research and life sciences include the elemental imaging of thin slices of brain tissue or applications in proteome analysis by combination with matrix-assisted laser desorption/ionization MS to study phospho- and metal- containing proteins will be discussed.


Subject(s)
Brain Chemistry , Brain/anatomy & histology , Mass Spectrometry/methods , Metals, Heavy/analysis , Animals , Brain/metabolism , Humans , Lasers , Metals, Heavy/metabolism , Microchemistry , Snails , Spectrometry, Mass, Matrix-Assisted Laser Desorption-Ionization/methods
3.
Anal Chem ; 79(16): 6074-80, 2007 Aug 15.
Article in English | MEDLINE | ID: mdl-17622184

ABSTRACT

Quantitative imaging analysis of endogenous an exogenous elements throughout entire organisms is required for studies of bioavailability, transport processes, distribution, contamination and to monitor environmental risks using indicator organisms. An imaging mass spectrometric technique using laser ablation inductively coupled plasma mass spectrometry (LA-ICPMS) was developed to analyze selenium and metal distributions in longitudinal sections (thickness, 100 microm) of entire slugs (genus arion). Slugs were fed with either a placebo or solutions containing 1000 microg mL(-1) Se. Samples (raster area, 25 mmx45 mm) were scanned together with synthetic matrix-matched standards with a focused beam of a Nd:YAG laser (wavelength, 266 nm; diameter of laser crater, 50 microm; laser power density, 3x10(9) W cm(-2)) in a large laser ablation chamber. The ablated material was transported with argon as carrier gas to the ICP ion source at a double focusing sector field ICPMS. Ion intensities of selenium (78Se+, 82Se+) were measured together with 13C+, 63Cu+, and 64Zn+ within the entire tissue section. The regression coefficient of the calibration curve was 0.998. Inhomogeneous distributions for Se but also for C, Cu, and Zn were found. Selenium was enriched in the kidney (150 microg g(-1) in Se-treated animals versus 15 microg g(-1) in the placebo-treated animal, respectively) and in the digestive gland (200 microg g(-1) versus 25 microg g(-1)). Highest Se concentrations were detected in the gut of Se-treated slugs (250 microg g(-1)), and additional Se occurred in the skin of these animals. Cu was enriched in the heart and the mucous ventral skin. Interestingly, in addition to the localization in the digestive gland, Zn was detected only in the dorsal skin but not the ventral skin. The developed analytical technique allows the quantitative imaging of selenium together with selected metals in thin sections of biological tissue with limits of detection at the submicrogram per gram range.


Subject(s)
Copper/analysis , Environmental Monitoring/methods , Mass Spectrometry/methods , Selenium/pharmacokinetics , Zinc/analysis , Animals , Gastropoda , Lasers , Mass Spectrometry/standards , Tissue Distribution