1.
J Cataract Refract Surg ; 48(2): 247-250, 2022 Feb 01.
Article in English | MEDLINE | ID: mdl-34670946

ABSTRACT

In-the-bag intraocular lens (IOL) dislocation is a well-known complication after cataract surgery. As the number of cataract surgeries performed annually continues to increase, so will the incidence of IOL dislocations requiring surgical correction. Described is a new technique for rescue and refixation of a single-piece acrylic IOL. In this method, a new instrument called the IOL punch is used to create a hole at the optic-haptic junction or along the border of the optic, which acts as an anchor point for centration and subsequent scleral fixation of a dislocated IOL. The IOL punch allows for precise intraocular manipulation of the IOL and is less invasive compared with popular scleral fixation methods. This innovative technique may decrease the risk for postoperative complications and allows patients to maintain or recover previous uncorrected visual acuity by circumventing the need for IOL explantation or exchange.


Subject(s)
Lenses, Intraocular , Humans , Lens Implantation, Intraocular , Postoperative Complications , Retrospective Studies , Sclera/surgery , Suture Techniques
2.
Eye Contact Lens ; 31(6): 291-3, 2005 Nov.
Article in English | MEDLINE | ID: mdl-16284511

ABSTRACT

PURPOSE: Approximately 100 surgical fires take place in the United States each year. Recently, an ophthalmic lubricant was blamed for burning a child's eye while oxygen was administered during surgery. This study sought to determine whether four common ocular lubricants would ignite and sustain combustion in an oxygen-rich or standard room air environment. METHODS: A model head was modified to allow placement of a cow eye and marked with 1-inch gradations from the eye. A nasal cannula supplied room air and 100% oxygen at flow rates of 0, 2, 4, and 6 L/minute. Four common ocular lubricants were chosen and placed on the eye before attempted ignition. The ignition source (an AccuTemp disposable electrocautery unit and unipolar and bipolar cautery set at 10, 20, and 30 watts) was brought down from the hairline toward the cannula. Each lubricant was tested with each ignition source and each room air/oxygen flow rate. RESULTS: None of the ocular lubricants ignited under any of the experimental environments tested. A small surface flame was noted with the AccuTemp electrocautery unit, but it did not create a flash fire during the experiment. CONCLUSIONS: The ocular lubricants in this experiment showed no detectable tendency to ignite, even with direct application of the ignition source. Factors such as body hair or oxygen pooling likely provided the conditions necessary for the surgical fire. Most importantly, the ophthalmic lubricants tested actually protected the corneal epithelium and decreased damage to the conjunctiva and lids.


Subject(s)
Electrocoagulation/adverse effects , Eye Burns/etiology , Fires , Ointments/adverse effects , Operating Rooms , Oxygen/adverse effects , Animals , Cattle , Equipment Safety , Humans , Lubrication , Models, Biological , Risk Factors