Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Med Dosim ; 20(2): 95-8, 1995.
Article in English | MEDLINE | ID: mdl-7632351

ABSTRACT

Frequency of use of asymmetric collimation (AC) at an academic radiation oncology center equipped with AC-capable linear accelerators was determined, and the type of use was cataloged. Records of patients beginning radiation treatment at U.C. Davis Cancer Center within a 3-month period (3/1/92 to 5/31/92) were reviewed. Forty-seven percent of 102 patients and 56% of 123 courses of treatment involved AC. Six common uses of AC were identified: beam-split field matching, planned boosts, other field size changes, adjustments to match divergent fields, matchline feathering, and opposed tangential fields. This study demonstrates that asymmetric collimation is a useful and powerful clinical treatment tool with widespread applications to radiation therapy.


Subject(s)
Particle Accelerators , Radiotherapy, High-Energy/instrumentation , Cohort Studies , Humans , Radiotherapy Dosage , Radiotherapy, High-Energy/methods
2.
Int J Radiat Oncol Biol Phys ; 27(4): 921-6, 1993 Nov 15.
Article in English | MEDLINE | ID: mdl-8244824

ABSTRACT

PURPOSE: To determine the magnitude of patient positioning errors associated with six field conformal therapy for carcinoma of the prostate, and to assess the impact of alpha-cradle immobilization on these errors. METHODS AND MATERIALS: The records of 22 patients, treated at two of the treatment facilities within our department, using computed tomography-planned conformal six field therapy for carcinoma of the prostate, were reviewed. At one facility (UCD), patients were routinely treated with immobilization, while at the other (UCSF) no rigid immobilization was used. Portal films of patients treated at both facilities were subsequently reviewed, and the deviation of each portal from the simulation film was determined (simulation-to-treatment variability). In addition, for each patient, the average deviation of each portal film from the average portal film (treatment-to-treatment variability) was determined. RESULTS: The mean and median simulation-to-treatment variability was 0.4 cm for those patients treated with immobilization, versus 0.6 cm for those treated without immobilization. The 90th percentile of simulation-to-treatment variability was 0.7 cm for those patients treated with immobilization, versus 1.1 cm for those not immobilized. There was a significant reduction in the number of portals observed with errors of > or = 0.50 cm (132/201 vs. 37/87, 66% vs. 43%; p < 0.001), 0.75 cm (184/201 vs. 59/87, 92% vs. 68%; p < 0.001), and 1.0 cm (196/201 vs. 74/87, 98% vs. 85%; p < 0.001) for patients treated with immobilization. There was also a significant reduction in the number of patients with treatment-to-treatment variability > or = 0.5 cm (1/10 vs. 8/12; p = 0.01) for patients treated with immobilization. CONCLUSION: The use of immobilization devices significantly reduces errors in patient positioning, potentially permitting the use of smaller treatment volumes. Immobilization should be a component of conformal radiation therapy programs for prostate carcinoma.


Subject(s)
Immobilization , Prostatic Neoplasms/radiotherapy , Radiotherapy, High-Energy/methods , Computer Simulation , Humans , Male , Posture , Prostatic Neoplasms/epidemiology , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted , Retrospective Studies
SELECTION OF CITATIONS