Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add more filters










Database
Language
Publication year range
1.
Catheter Cardiovasc Interv ; 92(3): E246-E253, 2018 09 01.
Article in English | MEDLINE | ID: mdl-29243353

ABSTRACT

OBJECTIVES: In this first-in-human study, we prospectively studied the vascular compatibility and mechanical performance of a novel bare ultra-high molecular weight amorphous PLLA bioresorbable scaffold (BRS, FORTITUDE®, Amaranth Medical, Mountain View, California) up to two years after implantation using multimodality imaging techniques. BACKGROUND: The vascular biocompatibility of polymers used in BRS has not been fully characterized in the absence of anti-proliferative drugs. METHODS: A total of 10 patients undergoing single scaffold implantation were included in the final analysis and were followed up using optical coherence tomography (OCT) at 2-years. All devices were implanted under angiographic and intravascular ultrasound (IVUS) guidance. Angiographic and IVUS follow up was performed at 6 months. Additionally, angiography and OCT imaging were performed at 2-years. RESULTS: At 6 months, mean intra-scaffold angiographic MLD slightly decreased from baseline procedural values. However, at 2 years, mean angiographic MLD increased (post procedure; 2.9 [2.7, 3.1] mm vs. 6 months; 2.1 [1.6, 2.5] vs. 2 years; 2.4 [2.1, 2.6], P = .001). Also, angiographic percent diameter stenosis decreased and late lumen gain increased between 6 months and 2 years follow up. Mean neointimal hyperplasia volume assessed by IVUS at 6 months was 26% [15.2, 29.3]. At 2 years OCT follow up neointimal hyperplasia volume was 24.2% [19.4, 28.9]. No presence of neoatherosclerosis was identified in any of the analyzed cases. CONCLUSION: At 2 years, this novel PLLA-based BRS induced expansive vascular remodeling from 6 to 24 months, a biological phenomenon that appears to be independent of the presence of anti-proliferative drugs.


Subject(s)
Absorbable Implants , Coronary Angiography , Coronary Artery Disease/therapy , Coronary Vessels/diagnostic imaging , Percutaneous Coronary Intervention/instrumentation , Polyesters/chemistry , Tomography, Optical Coherence , Ultrasonography, Interventional , Vascular Remodeling , Aged , Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/pathology , Coronary Artery Disease/physiopathology , Coronary Vessels/pathology , Coronary Vessels/physiopathology , Feasibility Studies , Female , Humans , Hyperplasia , Male , Middle Aged , Molecular Weight , Multimodal Imaging , Neointima , Percutaneous Coronary Intervention/adverse effects , Predictive Value of Tests , Prospective Studies , Prosthesis Design , Time Factors , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...