Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 141
Filter
1.
Nanoscale Horiz ; 2024 Sep 04.
Article in English | MEDLINE | ID: mdl-39229772

ABSTRACT

Neuroelectronic prostheses are being developed for restoring vision at the retinal level in patients who have lost their sight due to photoreceptor loss. The core component of these devices is the electrode array, which enables interfacing with retinal neurons. Generating the perception of meaningful images requires high-density microelectrode arrays (MEAs) capable of precisely activating targeted retinal neurons. Achieving this precision necessitates the downscaling of electrodes to micrometer dimensions. However, miniaturization increases electrode impedance, which poses challenges by limiting the amount of current that can be delivered, thereby impairing the electrode's capability for effective neural modulation. Additionally, it elevates noise levels, reducing the signal quality of the recorded neural activity. This report focuses on evaluating reduced graphene oxide (rGO) based devices for interfacing with the retina, showcasing their potential in vision restoration. Our findings reveal low impedance and high charge injection limit for microscale rGO electrodes, confirming their suitability for developing next-generation high-density retinal devices. We successfully demonstrated bidirectional interfacing with cell cultures and explanted retinal tissue, enabling the identification and modulation of multiple cells' activity. Additionally, calcium imaging allowed real-time monitoring of retinal cell dynamics, demonstrating a significant reduction in activated areas with small-sized electrodes. Overall, this study lays the groundwork for developing advanced rGO-based MEAs for high-acuity visual prostheses.

2.
J ECT ; 2024 Jul 18.
Article in English | MEDLINE | ID: mdl-39024187

ABSTRACT

INTRODUCTION: Electroconvulsive therapy (ECT) is effective in treating severe depression and other neuropsychiatric disorders, but how the presence of an anatomical anomaly affects the electrical pathways between the electrodes remains unclear. We investigate the difference in electric field (E-field) distribution during ECT in the brain of a patient with an arachnoid cyst relative to hypothetical condition where the cyst was not present. METHODS: Magnetic resonance imaging scans of the head of a patient with a large left frontal cyst were segmented to construct a finite element model to study the E-field distribution during ECT. Five electrode configurations were investigated: right unilateral, left unilateral, bifrontal, and bitemporal and left anterior right temporal. The E-field distributions for all montages were compared with a hypothetical condition where brain tissue and electrical conductivity from the right frontal region was mirrored across the longitudinal fissure into the cyst. RESULTS: Differences in mean E-field and 90th percentile E-fields were mainly observed in brain regions closest to the cyst including the left inferior frontal gyrus and left middle frontal gyrus. This trend was most pronounced in montages where the electrodes were closest to the cyst such as left unilateral and bitemporal. CONCLUSION: The presence of a highly conductive cyst close to the ECT electrode tended to attract current into the cyst region, altering current pathways, with potential implications for therapeutic efficacy and safety. Placing electrodes farther away from the cyst is likely to minimize any effects on the E-field distribution and potentially clinical outcomes.

4.
Biomacromolecules ; 25(5): 3131-3140, 2024 May 13.
Article in English | MEDLINE | ID: mdl-38554085

ABSTRACT

The sulfated marine polysaccharides, fucoidan and λ-carrageenan, are known to possess anti-inflammatory, immunomodulatory, and cellular protective properties. Although they hold considerable promise for tissue engineering constructs, their covalent cross-linking in hydrogels and comparative bioactivities to cells are absent from the literature. Thus, fucoidan and λ-carrageenan were modified with methacrylate groups and were covalently cross-linked with the synthetic polymer poly(vinyl alcohol)-methacrylate (PVA-MA) to form 20 wt % biosynthetic hydrogels. Identical degrees of methacrylation were confirmed by 1H NMR, and covalent conjugation was determined by using a colorimetric 1,9-dimethyl-methylene blue (DMMB) assay. Pancreatic beta cells were encapsulated in the hydrogels, followed by culturing in the 3D environment for a prolonged period of 32 days and evaluation of the cellular functionality by live/dead, adenosine 5'-triphosphate (ATP) level, and insulin secretion. The results confirmed that fucoidan and λ-carrageenan exhibited ∼12% methacrylate substitution, which generated hydrogels with stable conjugation of the polysaccharides with PVA-MA. The cells encapsulated in the PVA-fucoidan hydrogels demonstrated consistently high ATP levels over the culture period. Furthermore, only cells in the PVA-fucoidan hydrogels retained glucose responsiveness, demonstrating comparatively higher insulin secretion in response to glucose. In contrast, cells in the PVA-λ-carrageenan and the PVA control hydrogels lost all glucose responsiveness. The present work confirms the superior effects of chemically modified fucoidan over λ-carrageenan on pancreatic beta cell survival and function in covalently cross-linked hydrogels, thereby illustrating the importance of differential polysaccharide structural features on their biological effects.


Subject(s)
Carrageenan , Hydrogels , Polysaccharides , Carrageenan/chemistry , Carrageenan/pharmacology , Polysaccharides/chemistry , Polysaccharides/pharmacology , Hydrogels/chemistry , Hydrogels/pharmacology , Animals , Insulin-Secreting Cells/metabolism , Insulin-Secreting Cells/drug effects , Polyvinyl Alcohol/chemistry , Cross-Linking Reagents/chemistry , Rats , Methacrylates/chemistry , Methacrylates/pharmacology , Cell Survival/drug effects , Insulin/chemistry , Insulin/metabolism
5.
Biomed Eng Online ; 23(1): 24, 2024 Feb 22.
Article in English | MEDLINE | ID: mdl-38388416

ABSTRACT

Aortic stenosis, hypertension, and left ventricular hypertrophy often coexist in the elderly, causing a detrimental mismatch in coupling between the heart and vasculature known as ventricular-vascular (VA) coupling. Impaired left VA coupling, a critical aspect of cardiovascular dysfunction in aging and disease, poses significant challenges for optimal cardiovascular performance. This systematic review aims to assess the impact of simulating and studying this coupling through computational models. By conducting a comprehensive analysis of 34 relevant articles obtained from esteemed databases such as Web of Science, Scopus, and PubMed until July 14, 2022, we explore various modeling techniques and simulation approaches employed to unravel the complex mechanisms underlying this impairment. Our review highlights the essential role of computational models in providing detailed insights beyond clinical observations, enabling a deeper understanding of the cardiovascular system. By elucidating the existing models of the heart (3D, 2D, and 0D), cardiac valves, and blood vessels (3D, 1D, and 0D), as well as discussing mechanical boundary conditions, model parameterization and validation, coupling approaches, computer resources and diverse applications, we establish a comprehensive overview of the field. The descriptions as well as the pros and cons on the choices of different dimensionality in heart, valve, and circulation are provided. Crucially, we emphasize the significance of evaluating heart-vessel interaction in pathological conditions and propose future research directions, such as the development of fully coupled personalized multidimensional models, integration of deep learning techniques, and comprehensive assessment of confounding effects on biomarkers.


Subject(s)
Heart , Ventricular Function, Left , Aged , Humans , Aging , Coronary Vessels , Heart Ventricles
6.
J Neural Eng ; 21(1)2024 02 09.
Article in English | MEDLINE | ID: mdl-38290151

ABSTRACT

Objective.Current retinal prosthetics are limited in their ability to precisely control firing patterns of functionally distinct retinal ganglion cell (RGC) types. The aim of this study was to characterise RGC responses to continuous, kilohertz-frequency-varying stimulation to assess its utility in controlling RGC activity.Approach.We usedin vitropatch-clamp experiments to assess electrically-evoked ON and OFF RGC responses to frequency-varying pulse train sequences. In each sequence, the stimulation amplitude was kept constant while the stimulation frequency (0.5-10 kHz) was changed every 40 ms, in either a linearly increasing, linearly decreasing or randomised manner. The stimulation amplitude across sequences was increased from 10 to 300µA.Main results.We found that continuous stimulation without rest periods caused complex and irreproducible stimulus-response relationships, primarily due to strong stimulus-induced response adaptation and influence of the preceding stimulus frequency on the response to a subsequent stimulus. In addition, ON and OFF populations showed different sensitivities to continuous, frequency-varying pulse trains, with OFF cells generally exhibiting more dependency on frequency changes within a sequence. Finally, the ability to maintain spiking behaviour to continuous stimulation in RGCs significantly reduced over longer stimulation durations irrespective of the frequency order.Significance.This study represents an important step in advancing and understanding the utility of continuous frequency modulation in controlling functionally distinct RGCs. Our results indicate that continuous, kHz-frequency-varying stimulation sequences provide very limited control of RGC firing patterns due to inter-dependency between adjacent frequencies and generally, different RGC types do not display different frequency preferences under such stimulation conditions. For future stimulation strategies using kHz frequencies, careful consideration must be given to design appropriate pauses in stimulation, stimulation frequency order and the length of continuous stimulation duration.


Subject(s)
Retinal Ganglion Cells , Visual Prosthesis , Retinal Ganglion Cells/physiology , Action Potentials/physiology , Electric Stimulation/methods
7.
Article in English | MEDLINE | ID: mdl-38082599

ABSTRACT

Modulation of functionally distinct nerve fibers with bioelectronic devices provides a therapeutic opportunity for various diseases. In this study, we began by developing a computational model including four major subtypes of myelinated fibers and one unmyelinated fiber. Second, we used an intrafascicular electrode to perform kHz-frequency electric stimulation to preferentially modulate a population of fibers. Our model suggests that fiber physical properties and electrode-to-fascicle distance severely impacts stimulus-response relationships. Large diameter fibers (Aα- and Aß-) were only minimally influenced by the fascicle size and electrode location, while smaller diameter fibers (Aδ-, B- and C-) indicated a stronger dependency.Clinical Relevance- Our findings support the possibility of selectively modulating functionally-distinct nerve fibers using electrical stimulation in a small, localized region. Our model provides an effective tool to design next-generation implantable devices and therapeutic stimulation strategies toward minimizing off-target effects.


Subject(s)
Nerve Fibers, Myelinated , Vagus Nerve , Nerve Fibers, Myelinated/physiology , Microelectrodes , Vagus Nerve/physiology , Electric Stimulation
8.
Article in English | MEDLINE | ID: mdl-38083376

ABSTRACT

Photoreceptor loss and inner retinal network remodeling severely impacts the ability of retinal prosthetic devices to create artificial vision. We developed a computational model of a degenerating retina based on rodent data and tested its response to retinal electrical stimulation. This model includes detailed network connectivity and diverse neural intrinsic properties, capable of exploring how the degenerated retina influences the performance of electrical stimulation during the degeneration process. Our model suggests the possibility of quantitatively modulating retinal ON and OFF pathways between phase II and III of retinal degeneration without requiring any differences between ON and OFF RGC intrinsic cellular properties. The model also provided insights about how remodeling events influence stage-dependent differential electrical responses of ON and OFF pathways.Clinical Relevance-This data-driven model can guide future development of retinal prostheses and stimulation strategies that may benefit patients at different stages of retinal disease progression, particularly in the early and mid-stages, thus increasing their global acceptance.


Subject(s)
Retinal Degeneration , Visual Prosthesis , Humans , Retinal Degeneration/therapy , Retinal Ganglion Cells/physiology , Retina , Electric Stimulation
9.
Bioengineering (Basel) ; 10(6)2023 Jun 05.
Article in English | MEDLINE | ID: mdl-37370618

ABSTRACT

Additive manufacturing (3D printing) and computer-aided design (CAD) still have limited uptake in biomedical and bioengineering research and education, despite the significant potential of these technologies. The utility of organ-scale 3D-printed models of living structures is widely appreciated, while the workflows for microscopy data translation into tactile accessible replicas are not well developed yet. Here, we demonstrate an accessible and reproducible CAD-based methodology for generating 3D-printed scalable models of human cells cultured in vitro and imaged using conventional scanning confocal microscopy with fused deposition modeling (FDM) 3D printing. We termed this technology CiTo-3DP (Cells-in-Touch for 3D Printing). As a proof-of-concept, we created dismountable CiTo-3DP models of human epithelial, mesenchymal, and neural cells by using selectively stained nuclei and cytoskeletal components. We also provide educational and research context for the presented cellular models. In the future, the CiTo-3DP approach can be adapted to different imaging and 3D printing modalities and comprehensively present various cell types, subcellular structures, and extracellular matrices. The resulting CAD and 3D printed models could be used for a broad spectrum of education and research applications.

10.
Phys Eng Sci Med ; 46(2): 753-766, 2023 Jun.
Article in English | MEDLINE | ID: mdl-36995580

ABSTRACT

Magnetic resonance electrical properties tomography (MREPT) is an emerging imaging modality to noninvasively measure tissue conductivity and permittivity. Implementation of MREPT in the clinic requires repeatable measurements at a short scan time and an appropriate protocol. The aim of this study was to investigate the repeatability of conductivity measurements using phase-based MREPT and the effects of compressed SENSE (CS), and RF shimming on the precision of conductivity measurements. Conductivity measurements using turbo spin echo (TSE) and three-dimensional balanced fast field echo (bFFE) with CS factors were repeatable. Conductivity measurement using bFFE phase showed smaller mean and variance that those measured by TSE. The conductivity measurements using bFFE showed minimal deviation with CS factors up to 8, with deviation increasing at CS factors > 8. Subcortical structures produced less consistent measurements than cortical parcellations at higher CS factors. RF shimming using full slice coverage 2D dual refocusing echo acquisition mode (DREAM) and full coverage 3D dual TR approaches further improved measurement precision. BFFE is a more optimal sequence than TSE for phase-based MREPT in brain. Depending on the area of the brain being measured, the scan can be safely accelerated with compressed SENSE without sacrifice of precision, offering the potential to employ MREPT in clinical research and applications. RF shimming with better field mapping further improves precision of the conductivity measures.


Subject(s)
Magnetic Resonance Imaging , Tomography , Magnetic Resonance Imaging/methods , Tomography/methods , Magnetic Resonance Spectroscopy , Brain/diagnostic imaging , Electric Conductivity
11.
J Neural Eng ; 19(6)2022 11 29.
Article in English | MEDLINE | ID: mdl-36368033

ABSTRACT

Objective.A major reason for poor visual outcomes provided by existing retinal prostheses is the limited knowledge of the impact of photoreceptor loss on retinal remodelling and its subsequent impact on neural responses to electrical stimulation. Computational network models of the neural retina assist in the understanding of normal retinal function but can be also useful for investigating diseased retinal responses to electrical stimulation.Approach.We developed and validated a biophysically detailed discrete neuronal network model of the retina in the software package NEURON. The model includes rod and cone photoreceptors, ON and OFF bipolar cell pathways, amacrine and horizontal cells and finally, ON and OFF retinal ganglion cells with detailed network connectivity and neural intrinsic properties. By accurately controlling the network parameters, we simulated the impact of varying levels of degeneration on retinal electrical function.Main results.Our model was able to reproduce characteristic monophasic and biphasic oscillatory patterns seen in ON and OFF neurons during retinal degeneration (RD). Oscillatory activity occurred at 3 Hz with partial photoreceptor loss and at 6 Hz when all photoreceptor input to the retina was removed. Oscillations were found to gradually weaken, then disappear when synapses and gap junctions were destroyed in the inner retina. Without requiring any changes to intrinsic cellular properties of individual inner retinal neurons, our results suggest that changes in connectivity alone were sufficient to give rise to neural oscillations during photoreceptor degeneration, and significant network connectivity destruction in the inner retina terminated the oscillations.Significance.Our results provide a platform for further understanding physiological retinal changes with progressive photoreceptor and inner RD. Furthermore, our model can be used to guide future stimulation strategies for retinal prostheses to benefit patients at different stages of disease progression, particularly in the early and mid-stages of RD.


Subject(s)
Retina , Retinal Degeneration , Humans , Retina/physiology , Synapses/physiology , Retinal Ganglion Cells/physiology
12.
Brain Stimul ; 15(6): 1389-1404, 2022.
Article in English | MEDLINE | ID: mdl-36241025

ABSTRACT

BACKGROUND: Vagal reflexes regulate homeostasis in visceral organs and systems through afferent and efferent neurons and nerve fibers. Small, unmyelinated, C-type afferents comprise over 80% of fibers in the vagus and form the sensory arc of autonomic reflexes of the gut, lungs, heart and vessels and the immune system. Selective bioelectronic activation of C-afferents could be used to mechanistically study and treat diseases of peripheral organs in which vagal reflexes are involved, but it has not been achieved. METHODS: We stimulated the vagus in rats and mice using trains of kHz-frequency stimuli. Stimulation effects were assessed using neuronal c-Fos expression, physiological and nerve fiber responses, optogenetic and computational methods. RESULTS: Intermittent kHz stimulation for 30 min activates specific motor and, preferentially, sensory vagus neurons in the brainstem. At sufficiently high frequencies (>5 kHz) and at intensities within a specific range (7-10 times activation threshold, T, in rats; 15-25 × T in mice), C-afferents are activated, whereas larger, A- and B-fibers, are blocked. This was determined by measuring fiber-specific acute physiological responses to kHz stimulus trains, and by assessing fiber excitability around kHz stimulus trains through compound action potentials evoked by probing pulses. Aspects of selective activation of C-afferents are explained in computational models of nerve fibers by how fiber size and myelin shape the response of sodium channels to kHz-frequency stimuli. CONCLUSION: kHz stimulation is a neuromodulation strategy to robustly and selectively activate vagal C-afferents implicated in physiological homeostasis and disease, over larger vagal fibers.


Subject(s)
Nerve Fibers, Myelinated , Vagus Nerve , Rats , Animals , Mice , Rats, Sprague-Dawley , Vagus Nerve/physiology , Nerve Fibers, Myelinated/physiology , Sensory Receptor Cells , Electric Stimulation/methods , Neurons, Afferent/physiology
13.
Sensors (Basel) ; 22(19)2022 Sep 23.
Article in English | MEDLINE | ID: mdl-36236334

ABSTRACT

A modified monopole patch antenna for microwave-based hemorrhagic or ischemic stroke recognition is presented in this article. The designed antenna is fabricated on a cost-effective FR-4 lossy material with a 0.02 loss tangent and 4.4 dielectric constant. Its overall dimensions are 0.32 λ × 0.28 λ × 0.007 λ, where λ is the lower bandwidth 1.3 GHz frequency wavelength. An inset feeding approach is utilized to feed the antenna to reduce the input impedance (z = voltage/current). A total bandwidth (below -10 dB) of 2.4 GHz (1.3-3.7 GHz) is achieved with an effective peak gain of over 6 dBi and an efficiency of over 90%. A time-domain analysis confirms that the antenna produces minimal signal distortion. Simulated and experimental findings share a lot of similarities. Brain tissue is penetrated by the antenna to a satisfactory degree, while still exhibiting a safe specific absorption rate (SAR). The maximum SAR value measured for the head model is constrained to be equal to or below 0.1409 W/kg over the entire usable frequency band. Evaluation of theoretical and experimental evidence indicates the intended antenna is appropriate for Microwave Imaging (MWI) applications.


Subject(s)
Microwave Imaging , Wireless Technology , Brain , Equipment Design , Microwaves
14.
Comput Biol Med ; 148: 105834, 2022 09.
Article in English | MEDLINE | ID: mdl-35816854

ABSTRACT

BACKGROUND: Fluid structure interaction simulations h hold promise in studying normal and abnormal cardiac function, including the effect of fluid dynamics on mitral valve (MV) leaflet motion. The goal of this study was to develop a 3D fluid structure interaction computational model to simulate bileaflet MV when interacting with blood motion in left ventricle (LV). METHODS: The model consists of ideal geometric-shaped MV leaflets and the LV, with MV dimensions based on human anatomical measurements. An experimentally-based hyperelastic isotropic material was used to model the mechanical behaviour of the MV leaflets, with chordae tendineae and papillary muscle tips also incorporated. LV myocardial tissue was prescribed using a transverse isotropic hyperelastic formulation. Incompressible Navier-Stokes fluid formulations were used to govern the blood motion, and the Arbitrary Lagrangian Eulerian (ALE) method was employed to determine the mesh deformation of the fluid and solid domains due to trans-valvular pressure on MV boundaries and the resulting leaflet movement. RESULTS: The LV-MV generic model was able to reproduce physiological MV leaflet opening and closing profiles resulting from the time-varying atrial and ventricular pressures, as well as simulating normal and prolapsed MV states. Additionally, the model was able to simulate blood flow patterns after insertion of a prosthetic MV with and without left ventricular outflow tract flow obstruction. In the MV-LV normal model, the regurgitant blood flow fraction was 10.1 %, with no abnormality in cardiac function according to the mitral regurgitation severity grades reported by the American Society of Echocardiography. CONCLUSION: Our simulation approach provides insights into intraventricular fluid dynamics in a contracting LV with normal and prolapsed MV function, as well as aiding in the understanding of possible complications after transcatheter MV implantation prior to clinical trials.


Subject(s)
Heart Valve Prosthesis , Mitral Valve Insufficiency , Chordae Tendineae , Heart Ventricles , Humans , Mitral Valve
15.
Int J Numer Method Biomed Eng ; 38(8): e3616, 2022 08.
Article in English | MEDLINE | ID: mdl-35582823

ABSTRACT

In this study, we present a varying-radius cable equation for nerve fibres taking into account the varying diameter along the neuronal segments. Finite element neuronal models utilising the classical (fixed-radius) and varying-radius cable formulations were compared using simple and realistic morphologies under intra- and extracellular electrical stimulation protocols. We found that the use of the classical cable equation to model intracellular neural electrical stimulation exhibited an error of 17% in a passive resistive cable model with abrupt change in radius from 1 to 2 µm, when compared to the known analytical solution and varying-radius cable formulation. This error was observed to increase substantially using more realistic neuron morphologies and branching structures. In the case of extracellular stimulation however, the difference between the classical and varying-radius formulations was less pronounced, but we expect this difference will increase under more complex stimulation paradigms such as high-frequency stimulation. We conclude that for computational neuroscience applications, it is essential to use the varying-radius cable equation for accurate prediction of neuronal responses under electrical stimulation.


Subject(s)
Models, Neurological , Radius , Electric Stimulation , Nerve Fibers/physiology
16.
Biomech Model Mechanobiol ; 21(1): 261-275, 2022 Feb.
Article in English | MEDLINE | ID: mdl-35079931

ABSTRACT

False lumen thrombosis (FLT) in type B aortic dissection has been associated with the progression of dissection and treatment outcome. Existing computational models mostly assume rigid wall behavior which ignores the effect of flap motion on flow and thrombus formation within the FL. In this study, we have combined a fully coupled fluid-structure interaction (FSI) approach with a shear-driven thrombosis model described by a series of convection-diffusion reaction equations. The integrated FSI-thrombosis model has been applied to an idealized dissection geometry to investigate the interaction between vessel wall motion and growing thrombus. Our simulation results show that wall compliance and flap motion can influence the progression of FLT. The main difference between the rigid and FSI models is the continuous development of vortices near the tears caused by drastic flap motion up to 4.45 mm. Flap-induced high shear stress and shear rates around tears help to transport activated platelets further to the neighboring region, thus speeding up thrombus formation during the accelerated phase in the FSI models. Reducing flap mobility by increasing the Young's modulus of the flap slows down the thrombus growth. Compared to the rigid model, the predicted thrombus volume is 25% larger using the FSI-thrombosis model with a relatively mobile flap. Furthermore, our FSI-thrombosis model can capture the gradual effect of thrombus growth on the flow field, leading to flow obstruction in the FL, increased blood viscosity and reduced flap motion. This model is a step closer toward simulating realistic thrombus growth in aortic dissection, by taking into account the effect of intimal flap and vessel wall motion.


Subject(s)
Aortic Dissection , Thrombosis , Computer Simulation , Humans , Models, Cardiovascular , Stress, Mechanical
17.
EClinicalMedicine ; 43: 101252, 2022 Jan.
Article in English | MEDLINE | ID: mdl-35028544

ABSTRACT

BACKGROUND: Assessment of spine alignment is crucial in the management of scoliosis, but current auto-analysis of spine alignment suffers from low accuracy. We aim to develop and validate a hybrid model named SpineHRNet+, which integrates artificial intelligence (AI) and rule-based methods to improve auto-alignment reliability and interpretability. METHODS: From December 2019 to November 2020, 1,542 consecutive patients with scoliosis attending two local scoliosis clinics (The Duchess of Kent Children's Hospital at Sandy Bay in Hong Kong; Queen Mary Hospital in Pok Fu Lam on Hong Kong Island) were recruited. The biplanar radiographs of each patient were collected with our medical machine EOS™. The collected radiographs were recaptured using smartphones or screenshots, with deidentified images securely stored. Manually labelled landmarks and alignment parameters by a spine surgeon were considered as ground truth (GT). The data were split 8:2 to train and internally test SpineHRNet+, respectively. This was followed by a prospective validation on another 337 patients. Quantitative analyses of landmark predictions were conducted, and reliabilities of auto-alignment were assessed using linear regression and Bland-Altman plots. Deformity severity and sagittal abnormality classifications were evaluated by confusion matrices. FINDINGS: SpineHRNet+ achieved accurate landmark detection with mean Euclidean distance errors of 2·78 and 5·52 pixels on posteroanterior and lateral radiographs, respectively. The mean angle errors between predictions and GT were 3·18° and 6·32° coronally and sagittally. All predicted alignments were strongly correlated with GT (p < 0·001, R2 > 0·97), with minimal overall difference visualised via Bland-Altman plots. For curve detections, 95·7% sensitivity and 88·1% specificity was achieved, and for severity classification, 88·6-90·8% sensitivity was obtained. For sagittal abnormalities, greater than 85·2-88·9% specificity and sensitivity were achieved. INTERPRETATION: The auto-analysis provided by SpineHRNet+ was reliable and continuous and it might offer the potential to assist clinical work and facilitate large-scale clinical studies. FUNDING: RGC Research Impact Fund (R5017-18F), Innovation and Technology Fund (ITS/404/18), and the AOSpine East Asia Fund (AOSEA(R)2019-06).

18.
IEEE Rev Biomed Eng ; 15: 309-324, 2022.
Article in English | MEDLINE | ID: mdl-34185649

ABSTRACT

Development of cardiac multiphysics models has progressed significantly over the decades and simulations combining multiple physics interactions have become increasingly common. In this review, we summarise the progress in this field focusing on various approaches of integrating ventricular structures. electrophysiological properties, myocardial mechanics, as well as incorporating blood hemodynamics and the circulatory system. Common coupling approaches are discussed and compared, including the advantages and shortcomings of each. Currently used strategies for patient-specific implementations are highlighted and potential future improvements considered.


Subject(s)
Heart Ventricles , Models, Cardiovascular , Computer Simulation , Heart , Hemodynamics , Humans
20.
Annu Int Conf IEEE Eng Med Biol Soc ; 2021: 6033-6036, 2021 11.
Article in English | MEDLINE | ID: mdl-34892492

ABSTRACT

We have investigated selective electrical stimulation of myelinated nerve fibers using a computational model of temporal interfering (TI) fields. The model consists of two groups of electrodes placed on the outer bundle surface, each group stimulated at a different frequency. We manipulated the stimulus waveform, magnitude and frequency of short-duration stimuli (70ms), and investigated fiber-specific stimulus-elicited compound action potentials. Results show that under 100Hz & 200Hz TI stimulation with 0.6mA total current shared by the electrodes, continuous action potentials were generated in deeper nerve fibers, and that the firing region was steerable by changing individual electrode currents. This study provides a promising platform for non-invasive nerve bundle stimulation by TI fields.


Subject(s)
Electricity , Nerve Fibers, Myelinated , Action Potentials , Electric Stimulation , Electrodes
SELECTION OF CITATIONS
SEARCH DETAIL