Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 9 de 9
Filter
1.
Ophthalmology ; 124(5): 688-696, 2017 05.
Article in English | MEDLINE | ID: mdl-28187977

ABSTRACT

PURPOSE: To quantify retinal nerve fiber layer (RNFL) changes in patients with multiple sclerosis (MS) and healthy controls with a 5-year follow-up and to analyze correlations between disability progression and RNFL degeneration. DESIGN: Observational and longitudinal study. PARTICIPANTS: One hundred patients with relapsing-remitting MS and 50 healthy controls. METHODS: All participants underwent a complete ophthalmic and electrophysiologic exploration and were re-evaluated annually for 5 years. MAIN OUTCOME MEASURES: Visual acuity (Snellen chart), color vision (Ishihara pseudoisochromatic plates), visual field examination, optical coherence tomography (OCT), scanning laser polarimetry (SLP), and visual evoked potentials. Expanded Disability Status Scale (EDSS) scores, disease duration, treatments, prior optic neuritis episodes, and quality of life (QOL; based on the 54-item Multiple Sclerosis Quality of Life Scale score). RESULTS: Optical coherence tomography (OCT) revealed changes in all RNFL thicknesses in both groups. In the MS group, changes were detected in average thickness and in the mean deviation using the GDx-VCC nerve fiber analyzer (Laser Diagnostic Technologies, San Diego, CA) and in the P100 latency of visual evoked potentials; no changes were detected in visual acuity, color vision, or visual fields. Optical coherence tomography showed greater differences in the inferior and temporal RNFL thicknesses in both groups. In MS patients only, OCT revealed a moderate correlation between the increase in EDSS and temporal and superior RNFL thinning. Temporal RNFL thinning based on OCT results was correlated moderately with decreased QOL. CONCLUSIONS: Multiple sclerosis patients exhibit a progressive axonal loss in the optic nerve fiber layer. Retinal nerve fiber layer thinning based on OCT results is a useful marker for assessing MS progression and correlates with increased disability and reduced QOL.


Subject(s)
Multiple Sclerosis/complications , Nerve Fibers/pathology , Optic Atrophy/etiology , Optic Nerve/pathology , Retinal Degeneration/etiology , Retinal Ganglion Cells/pathology , Tomography, Optical Coherence/methods , Adult , Axons/pathology , Disability Evaluation , Disease Progression , Female , Follow-Up Studies , Humans , Male , Middle Aged , Multiple Sclerosis/diagnosis , Multiple Sclerosis/rehabilitation , Optic Atrophy/diagnosis , Optic Atrophy/rehabilitation , Prognosis , Quality of Life , Retinal Degeneration/diagnosis , Retinal Degeneration/rehabilitation , Retrospective Studies , Time Factors , Visual Acuity
2.
Invest Ophthalmol Vis Sci ; 55(2): 696-705, 2014 Feb 04.
Article in English | MEDLINE | ID: mdl-24425856

ABSTRACT

PURPOSE: To evaluate correlations between visual evoked potentials (VEP), pattern electroretinogram (PERG), and macular and retinal nerve fiber layer (RNFL) thickness measured by optical coherence tomography (OCT) and the severity of Parkinson disease (PD). METHODS: Forty-six PD patients and 33 age and sex-matched healthy controls were enrolled, and underwent VEP, PERG, and OCT measurements of macular and RNFL thicknesses, and evaluation of PD severity using the Hoehn and Yahr scale to measure PD symptom progression, the Schwab and England Activities of Daily Living Scale (SE-ADL) to evaluate patient quality of life (QOL), and disease duration. Logistical regression was performed to analyze which measures, if any, could predict PD symptom progression or effect on QOL. RESULTS: Visual functional parameters (best corrected visual acuity, mean deviation of visual field, PERG positive (P) component at 50 ms -P50- and negative (N) component at 95 ms -N95- component amplitude, and PERG P50 component latency) and structural parameters (OCT measurements of RNFL and retinal thickness) were decreased in PD patients compared with healthy controls. OCT measurements were significantly negatively correlated with the Hoehn and Yahr scale, and significantly positively correlated with the SE-ADL scale. Based on logistical regression analysis, fovea thickness provided by OCT equipment predicted PD severity, and QOL and amplitude of the PERG N95 component predicted a lower SE-ADL score. CONCLUSIONS: Patients with greater damage in the RNFL tend to have lower QOL and more severe PD symptoms. Foveal thicknesses and the PERG N95 component provide good biomarkers for predicting QOL and disease severity.


Subject(s)
Axons/pathology , Evoked Potentials, Visual/physiology , Parkinson Disease/diagnosis , Quality of Life/psychology , Retinal Ganglion Cells/pathology , Aged , Aged, 80 and over , Electroretinography , Female , Humans , Male , Middle Aged , Parkinson Disease/classification , Parkinson Disease/psychology , Severity of Illness Index , Tomography, Optical Coherence , Visual Acuity/physiology , Visual Fields/physiology
3.
J Clin Neurophysiol ; 30(4): 376-81, 2013 Aug.
Article in English | MEDLINE | ID: mdl-23912576

ABSTRACT

PURPOSE: To evaluate the ability of visual evoked potentials and pattern electroretinograms (PERG) to detect subclinical axonal damage in patients during the early diagnostic stage of multiple sclerosis (MS). The authors also compared the ability of optical coherence tomography (OCT), PERG, and visual evoked potentials to detect axonal loss in MS patients and correlated the functional and structural properties of the retinal nerve fiber layer. METHODS: Two hundred twenty-eight eyes of 114 subjects (57 MS patients and 57 age- and sex-matched healthy controls) were included. The visual pathway was evaluated based on functional and structural assessments. All patients underwent a complete ophthalmic examination that included assessment of visual acuity, ocular motility, intraocular pressure, visual field, papillary morphology, OCT, visual evoked potentials, and PERG. RESULTS: Visual evoked potentials (P100 latency and amplitude), PERG (N95 amplitude and N95/P50 ratio), and OCT parameters differed significantly between MS patients and healthy subjects. Moderate significant correlations were found between visual evoked potentials or PERG parameters and OCT measurements. CONCLUSIONS: Axonal damage in ganglion cells of the visual pathway can be detected based on structural measures provided by OCT in MS patients and by the N95 component and N95/P50 index of PERG, thus providing good correlation between function and structure.


Subject(s)
Electroretinography/methods , Evoked Potentials, Visual/physiology , Multiple Sclerosis, Relapsing-Remitting/physiopathology , Occipital Lobe/physiopathology , Tomography, Optical Coherence/methods , Visual Pathways/physiopathology , Adult , Axons/pathology , Axons/physiology , Cross-Sectional Studies , Electroretinography/instrumentation , Female , Humans , Male , Middle Aged , Multiple Sclerosis, Relapsing-Remitting/complications , Multiple Sclerosis, Relapsing-Remitting/pathology , Nerve Fibers/pathology , Occipital Lobe/pathology , Prospective Studies , Retina/pathology , Retina/physiopathology , Tomography, Optical Coherence/instrumentation , Vision Tests , Visual Pathways/pathology
4.
Am J Ophthalmol ; 156(2): 293-303.e2, 2013 Aug.
Article in English | MEDLINE | ID: mdl-23677138

ABSTRACT

PURPOSE: To evaluate the effect of uncomplicated cataract phacoemulsification on the measurements of visual evoked potentials (VEP), pattern electroretinogram (PERG), and macular and retinal nerve fiber layer (RNFL) using 2 spectral-domain optical coherence tomography (OCT) instruments, the Cirrus OCT (Carl Zeiss Meditech) and Spectralis OCT (Heidelberg Engineering), in patients with retinitis pigmentosa (RP), and to assess the reliability of the OCT measurements before and after cataract surgery. DESIGN: Observational cross-sectional study. METHODS: Thirty-five eyes of 35 patients with RP (20 men and 15 women, 45-66 years) who underwent cataract phacoemulsification were studied. At 1 month before and 1 month after surgery, visual acuity, VEP, PERG, and 3 repetitions of scans using the RNFL and macular analysis protocols of the Cirrus and Spectralis OCT instruments were performed. The differences in measurements between the 2 visits were analyzed. Repeatability of OCT measurements was evaluated by calculating the coefficients of variation. RESULTS: VEP amplitude, RNFL thicknesses provided by Cirrus and Spectralis, and macular measurements provided by Cirrus OCT differed between the 2 visits. VEP latency, PERG measurements, and macular thicknesses provided by the Spectralis OCT before surgery did not differ significantly from those after surgery. The OCT repeatability was better after surgery, with lower coefficients of variation for scans performed after surgical removal of the cataract. The nuclear, cortical, and posterior subcapsular types of cataracts did not show different repeatability. CONCLUSIONS: The presence of cataracts affects VEP amplitude, RNFL, and macular measurements performed with OCT in eyes with RP. Image repeatability significantly improves after cataract phacoemulsification.


Subject(s)
Evoked Potentials, Visual/physiology , Nerve Fibers/pathology , Phacoemulsification , Retina/physiopathology , Retinal Ganglion Cells/pathology , Retinitis Pigmentosa/physiopathology , Tomography, Optical Coherence , Aged , Cataract/physiopathology , Cross-Sectional Studies , Electroretinography , Female , Follow-Up Studies , Humans , Male , Middle Aged , Neurophysiology , Prospective Studies , Retinitis Pigmentosa/diagnosis , Visual Acuity/physiology
5.
Neurology ; 81(1): 76-83, 2013 Jul 02.
Article in English | MEDLINE | ID: mdl-23709591

ABSTRACT

OBJECTIVE: To evaluate correlations between longitudinal changes in neuro-ophthalmologic measures and quality of life (QOL) and disability in patients with multiple sclerosis (MS), using optical coherence tomography (OCT), visual evoked potentials (VEP), and visual field examination. METHODS: Fifty-four patients with relapsing-remitting MS were enrolled in this study and underwent Multiple Sclerosis Quality of Life questionnaire (54 items) (MSQOL-54) and Expanded Disability Status Scale (EDSS) evaluation, as well as complete neuro-ophthalmologic examination including visual field testing and retinal nerve fiber layer (RNFL) measurements using Cirrus and Spectralis OCT and VEP. All patients were re-evaluated at 12, 24, and 36 months. Logistical regression was performed to analyze which measures, if any, could predict QOL. RESULTS: Overall, RNFL thickness results at the baseline evaluation were significantly different from those at 3 years (p ≤ 0.05), but there were no differences in functional measures (visual acuity, contrast sensitivity, color vision, visual field, and VEP). A reduced MSQOL-54 score was associated with an increase in EDSS score and a decrease in both functional and structural parameters. Patients with longer MS duration presented with a lower MSQOL-54 score (reduction in QOL). CONCLUSIONS: Patients with progressive axonal loss as seen in RNFL results had a lower QOL and more functional disability.


Subject(s)
Multiple Sclerosis, Relapsing-Remitting/physiopathology , Quality of Life , Evoked Potentials, Visual/physiology , Humans , Multiple Sclerosis, Relapsing-Remitting/diagnosis , Nerve Fibers/physiology , Surveys and Questionnaires , Tomography, Optical Coherence/methods , Visual Field Tests/methods
6.
Retina ; 32(8): 1581-91, 2012 Sep.
Article in English | MEDLINE | ID: mdl-22922847

ABSTRACT

PURPOSE: To evaluate the ability of time-domain and Fourier-domain optical coherence tomographies (OCTs) to detect macular and retinal nerve fiber layer atrophies in retinitis pigmentosa (RP). To test the intrasession reproducibility using three OCT instruments (Stratus, Cirrus, and Spectralis). METHODS: Eighty eyes of 80 subjects (40 RP patients and 40 healthy subjects) underwent a visual field examination, together with 3 macular scans and 3 optic disk evaluations by the same experienced examiner using 3 OCT instruments. Differences between healthy and RP eyes were compared. The relationship between measurements with each OCT instrument was evaluated. Repeatability was studied by intraclass correlation coefficients and coefficients of variation. RESULTS: Macular and retinal nerve fiber layer atrophies were detected in RP patients for all OCT parameters. Macular and retinal nerve fiber layer thicknesses, as determined by the different OCTs, were correlated but significantly different (P < 0.05). Reproducibility was moderately high using Stratus, good using Cirrus and Spectralis, and excellent using the Tru-track technology of Spectralis. In RP eyes, measurements showed higher variability compared with healthy eyes. CONCLUSION: Differences in thickness measurements existed between OCT instruments, despite there being a high degree of correlation. Fourier-domain OCT can be considered a valid and repeatability technique to detect retinal nerve fiber layer atrophy in RP patients.


Subject(s)
Macula Lutea/pathology , Nerve Fibers/pathology , Retinal Ganglion Cells/pathology , Retinitis Pigmentosa/diagnosis , Tomography, Optical Coherence/instrumentation , Adult , Aged , Cross-Sectional Studies , Female , Fourier Analysis , Humans , Male , Middle Aged , Organ Size , Prospective Studies , Reproducibility of Results , Time Factors , Tomography, Optical Coherence/standards , Visual Acuity/physiology
7.
Br J Ophthalmol ; 95(11): 1577-82, 2011 Nov.
Article in English | MEDLINE | ID: mdl-21785155

ABSTRACT

AIM: To quantify structural and functional degeneration in the retinal nerve fibre layer (RNFL) of patients with multiple sclerosis (MS) over a 2-year time period, and to analyse the effect of prior optic neuritis (ON) as well as the duration and incidence of MS relapses. METHODS: 166 MS patients and 120 healthy controls underwent assessment of visual acuity and colour vision, visual field examination, optical coherence tomography, scanning laser polarimetry and visual evoked potentials (VEPs). All subjects were re-evaluated after a period of 12 and 24 months. RESULTS: Changes in the optic nerve were detected by structural measurements but not by functional assessments. Changes registered in MS patients were greater than changes in healthy controls (p<0.05). Eyes with previous ON showed a greater reduction of parameters in the baseline evaluation, but RNFL atrophy was not significantly greater in the longitudinal study. Patients with MS relapses showed a greater reduction of RNFL thickness and VEP amplitude compared with non-relapsing cases. Patients with and without treatment showed similar measurement reduction, but the non-treated group had a significantly higher increase in Expanded Disability Status Scale (p=0.029). CONCLUSIONS: MS causes progressive axonal loss in the optic nerve, regardless of a history of ON. This ganglion cell atrophy occurs in all eyes but is more marked in MS eyes than in healthy eyes.


Subject(s)
Multiple Sclerosis/pathology , Retinal Ganglion Cells/pathology , Adult , Aged , Atrophy/pathology , Atrophy/physiopathology , Axons/pathology , Disease Progression , Epidemiologic Methods , Female , Humans , Male , Middle Aged , Multiple Sclerosis/complications , Multiple Sclerosis/physiopathology , Optic Nerve/pathology , Optic Neuritis/etiology , Optic Neuritis/pathology , Tomography, Optical Coherence/methods , Visual Acuity/physiology , Visual Fields/physiology , Young Adult
8.
Eur J Ophthalmol ; 20(1): 167-73, 2010.
Article in English | MEDLINE | ID: mdl-19882541

ABSTRACT

PURPOSE: To quantify changes in the retinal nerve fiber layer (RNFL) of patients with multiple sclerosis (MS) over a 1-year time period and to compare the ability of noninvasive diagnostic imaging devices and visual evoked potentials (VEP) to detect axonal loss in these patients. METHODS: Eighty-one patients with MS underwent a complete ophthalmic examination that included assessment of visual acuity and color vision, refractive evaluation, visual field examination, optical coherence tomography (OCT), scanning laser polarimetry (GDx), and measurement of VEP. All the patients were re-evaluated after a period of 12 months in order to quantify any change in the RNFL. Only one randomly chosen eye from each patient was included in the study. RESULTS: Statistically significant differences between the 2 examinations were recorded for the overall mean and inferior RNFL thickness and the macular volume, as assessed by OCT, as well as for the temporal-superior-nasal-inferior-temporal average standard deviation provided by GDx. The greatest differences were obtained for the mean RNFL thickness (90.46 microm vs 85.96 microm). Changes in the optic nerve were detected by structural measurements but not by functional assessments. CONCLUSIONS: Axonal loss in the optic nerve of patients with MS is greater than that expected in healthy subjects, regardless of the presence of a previous optic neuritis.


Subject(s)
Multiple Sclerosis/physiopathology , Nerve Fibers/physiology , Optic Nerve/physiopathology , Retinal Ganglion Cells/physiology , Adult , Aged , Disease Progression , Evoked Potentials, Visual/physiology , Female , Humans , Longitudinal Studies , Male , Middle Aged , Scanning Laser Polarimetry , Tomography, Optical Coherence , Visual Acuity
SELECTION OF CITATIONS
SEARCH DETAIL
...