Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 64
Filter
1.
Pacing Clin Electrophysiol ; 47(5): 614-625, 2024 May.
Article in English | MEDLINE | ID: mdl-38558218

ABSTRACT

INTRODUCTION: The use of esophageal temperature monitoring (ETM) for the prevention of esophageal injury during atrial fibrillation (AF) ablation is often advocated. However, evidence supporting its use is scarce and controversial. We therefore aimed to review the evidence assessing the efficacy of ETM for the prevention of esophageal injury. METHODS: We performed a meta-analysis and systematic review of the available literature from inception to December 31, 2022. All studies comparing the use of ETM, versus no ETM, during radiofrequency (RF) AF ablation and which reported the incidence of endoscopically detected esophageal lesions (EDELs) were included. RESULTS: Eleven studies with a total of 1112 patients undergoing RF AF ablation were identified. Of those patients, 627 were assigned to ETM (56%). The overall incidence of EDELs was 9.8%. The use of ETM during AF ablation was associated with a non significant increase in the incidence of EDELs (12.3% with ETM, vs. 6.6 % without ETM, odds ratio, 1.44, 95%CI, 0.49, 4.22, p = .51, I2 = 72%). The use of ETM was associated with a significant increase in the energy delivered specifically on the posterior wall compared to patients without ETM (mean power difference: 5.13 Watts, 95% CI, 1.52, 8.74, p = .005). CONCLUSIONS: The use of ETM does not reduce the incidence of EDELs during RF AF ablation. The higher energy delivered on the posterior wall is likely attributable to a false sense of safety that may explain the lack of benefit of ETM. Further randomized controlled trials are needed to provide conclusive results.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Esophagus , Humans , Atrial Fibrillation/surgery , Atrial Fibrillation/prevention & control , Esophagus/injuries , Body Temperature , Monitoring, Intraoperative/methods , Intraoperative Complications/prevention & control
2.
Rev Med Suisse ; 20(856-7): 19-24, 2024 Jan 17.
Article in French | MEDLINE | ID: mdl-38231094

ABSTRACT

The year 2023 has been extremely rich in new publications in the various subfields of cardiology. Furthermore, the European Society of Cardiology (ESC) has issued revised guidelines focused on the management of acute coronary syndrome (ACS) and endocarditis, as well as an update on the recommendations for the management of heart failure and cardiovascular prevention. The most significant updates according to the Cardiology Department of CHUV are summarized in this review article.


L'année 2023 a été extrêmement riche en nouvelles publications dans les différents sous-domaines de la cardiologie. De plus, la Société européenne de cardiologie (ESC) a formulé des directives révisées axées sur le management du syndrome coronarien aigu (SCA) et de l'endocardite ainsi qu'une mise à jour des recommandations sur la prise en charge de l'insuffisance cardiaque et la prévention cardiovasculaire. Les nouveautés les plus importantes selon l'équipe du Service de cardiologie du CHUV sont résumées dans cet article de synthèse.


Subject(s)
Acute Coronary Syndrome , Cardiology , Endocarditis , Heart Failure , Humans , Heart Failure/diagnosis , Heart Failure/therapy , Acute Coronary Syndrome/diagnosis , Acute Coronary Syndrome/therapy
3.
Physiol Meas ; 45(2)2024 Feb 14.
Article in English | MEDLINE | ID: mdl-38266291

ABSTRACT

Objective.Cardiac arrhythmias are a leading cause of mortality worldwide. Wearable devices based on photoplethysmography give the opportunity to screen large populations, hence allowing for an earlier detection of pathological rhythms that might reduce the risks of complications and medical costs. While most of beat detection algorithms have been evaluated on normal sinus rhythm or atrial fibrillation recordings, the performance of these algorithms in patients with other cardiac arrhythmias, such as ventricular tachycardia or bigeminy, remain unknown to date.Approach. ThePPG-beatsopen-source framework, developed by Charlton and colleagues, evaluates the performance of the beat detectors namedQPPG,MSPTDandABDamong others. We applied thePPG-beatsframework on two newly acquired datasets, one containing seven different types of cardiac arrhythmia in hospital settings, and another dataset including two cardiac arrhythmias in ambulatory settings.Main Results. In a clinical setting, theQPPGbeat detector performed best on atrial fibrillation (with a medianF1score of 94.4%), atrial flutter (95.2%), atrial tachycardia (87.0%), sinus rhythm (97.7%), ventricular tachycardia (83.9%) and was ranked 2nd for bigeminy (75.7%) behindABDdetector (76.1%). In an ambulatory setting, theMSPTDbeat detector performed best on normal sinus rhythm (94.6%), and theQPPGdetector on atrial fibrillation (91.6%) and bigeminy (80.0%).Significance. Overall, the PPG beat detectorsQPPG,MSPTDandABDconsistently achieved higher performances than other detectors. However, the detection of beats from wrist-PPG signals is compromised in presence of bigeminy or ventricular tachycardia.


Subject(s)
Atrial Fibrillation , Tachycardia, Ventricular , Humans , Heart Rate , Atrial Fibrillation/diagnosis , Photoplethysmography/methods , Benchmarking , Tachycardia, Ventricular/diagnosis , Algorithms , Electrocardiography/methods
4.
Article in English | MEDLINE | ID: mdl-37977548

ABSTRACT

OBJECTIVE: To investigate the utility of simultaneous multi-catheter cryotherapy for the treatment of APs that were previously resistant to standard radiofrequency (RF) catheter ablation. BACKGROUND: Catheter ablation is established in the treatment of accessory pathways (AP), with high rates of permanent procedural success with a single attempt. However, there are still instances of acute procedural failure and AP recurrences with standard RF and cryotherapy methods. METHODS: Seven consecutive cases of pre-excitation syndromes with prior failed RF catheter ablation had the novel treatment. Cryotherapy was delivered using two 8 mm tip focal cryoablation catheters (Freezor® Max, Medtronic, Minneapolis, Minnesota, USA). RESULTS: Accessory pathway localisation was septal in 5 cases, left posterolateral in 1, right lateral in 1. In all cases, ablation of the AP was acutely successful with no procedural complications. Median procedure and fluoroscopy durations were 199 and 35 min, sequentially. Median Procedure duration fell significantly in the second half of series (174 min) compared to the first half (233 min, P = 0.05). One patient had evidence of a recurring AP conduction with pre-excitation at 5-week follow up. After a median follow up of 66.8+-6.5 months, 6 out of 7 patients remained asymptomatic and free of pre-excitation. CONCLUSION: Simultaneous multi-catheter cryotherapy is feasible, safe and can provide definitive cure of accessory pathways that were previously resistant to standard radiofrequency ablation. Further study is required in the assessment of this novel form of advanced cryotherapy to treat complex and resistant arrhythmias.

5.
J Clin Med ; 12(19)2023 Sep 29.
Article in English | MEDLINE | ID: mdl-37834932

ABSTRACT

Over the last few years, pacing of the conduction system (CSP) has emerged as the new standard pacing modality for bradycardia indications, allowing a more physiological ventricular activation compared to conventional right ventricular pacing. CSP has also emerged as an alternative modality to conventional biventricular pacing for the delivery of cardiac resynchronization therapy (CRT) in heart failure patients. However, if the initial clinical data seem to support this new physiological-based approach to CRT, the lack of large randomized studies confirming these preliminary results prevents CSP from being used routinely in clinical practice. Furthermore, concerns are still present regarding the long-term performance of pacing leads when employed for CSP, as well as their extractability. In this review article, we provide the state-of-the-art of CSP as an alternative to biventricular pacing for CRT delivery in heart failure patients. In particular, we describe the physiological concepts supporting this approach and we discuss the future perspectives of CSP in this context according to the implant techniques (His bundle pacing and left bundle branch area pacing) and the clinical data published so far.

6.
Europace ; 25(10)2023 Oct 05.
Article in English | MEDLINE | ID: mdl-37695314

ABSTRACT

AIMS: Stereotactic arrhythmia radioablation (STAR) has been recently introduced for the management of therapy-refractory ventricular tachycardia (VT). VT recurrences have been reported after STAR but the mechanisms remain largely unknown. We analysed recurrences in our patients after STAR. METHODS AND RESULTS: From 09.2017 to 01.2020, 20 patients (68 ± 8 y, LVEF 37 ± 15%) suffering from refractory VT were enrolled, 16/20 with a history of at least one electrical storm. Before STAR, an invasive electroanatomical mapping (Carto3) of the VT substrate was performed. A mean dose of 23 ± 2 Gy was delivered to the planning target volume (PTV). The median ablation volume was 26 mL (range 14-115) and involved the interventricular septum in 75% of patients. During the first 6 months after STAR, VT burden decreased by 92% (median value, from 108 to 10 VT/semester). After a median follow-up of 25 months, 12/20 (60%) developed a recurrence and underwent a redo ablation. VT recurrence was located in the proximity of the treated substrate in nine cases, remote from the PTV in three cases and involved a larger substrate over ≥3 LV segments in two cases. No recurrences occurred inside the PTV. Voltage measurements showed a significant decrease in both bipolar and unipolar signal amplitude after STAR. CONCLUSION: STAR is a new tool available for the treatment of VT, allowing for a significant reduction of VT burden. VT recurrences are common during follow-up, but no recurrences were observed inside the PTV. Local efficacy was supported by a significant decrease in both bipolar and unipolar signal amplitude.

7.
J Clin Med ; 12(16)2023 Aug 08.
Article in English | MEDLINE | ID: mdl-37629216

ABSTRACT

BACKGROUND: Device patients may require upgrade interventions from simpler to more complex cardiac implantable electronic devices. Prior to upgrading interventions, clinicians need to balance the risks and benefits of transvenous lead extraction (TLE), additional lead implantation or lead abandonment. However, evidence on procedural outcomes of TLE at the time of device upgrade is scarce. METHODS: This is a post hoc analysis of the investigator-initiated multicenter Swiss TLE registry. The objectives were to assess patient and procedural factors influencing TLE outcomes at the time of device upgrades. RESULTS: 941 patients were included, whereof 83 (8.8%) had TLE due to a device upgrade. Rotational mechanical sheaths were more often used in upgraded patients (59% vs. 42.7%, p = 0.015) and total median procedure time was longer in these patients (160 min vs. 105 min, p < 0.001). Clinical success rates of upgraded patients compared to those who received TLE due to other reasons were not different (97.6% vs. 93.0%, p = 0.569). Moreover, multivariable analysis showed that upgrade procedures were not associated with a greater risk for complications (HR 0.48, 95% confidence interval 0.14-1.57, p = 0.224; intraprocedural complication rate of upgraded patients 7.2% vs. 5.5%). Intraprocedural complications of upgraded patients were mostly associated with the implantation and not the extraction procedure (67% vs. 33% of complications). CONCLUSIONS: TLE during device upgrade is effective and does not attribute a disproportionate risk to the upgrade procedure.

8.
Front Cardiovasc Med ; 10: 1213165, 2023.
Article in English | MEDLINE | ID: mdl-37547255

ABSTRACT

Background: Cardiac sarcoidosis is associated with heart failure, conduction abnormalities, and life-threatening arrhythmias including ventricular tachycardia (VT). Radiotherapy has been suggested as a treatment for extra-cardiac sarcoidosis in patients refractory to immunomodulatory treatment. Methods: The effectiveness and safety of low-dose whole-heart radiotherapy for therapy refractory cardiac sarcoidosis were evaluated in a pre- and post-intervention case report comparing the 54 months before and after treatment. Immunomodulatory low-dose whole-heart irradiation as sarcoidosis treatment consisted of a 2 × 2 Gy scheme. Additionally, high-dose single-fraction stereotactic arrhythmia radioablation of 1 × 20 Gy was applied to the pro-arrhythmic region to manage the ventricular tachycardia episodes. Cardiac sarcoidosis disease activity was measured by hypermetabolic areas on repeated fluorodeoxyglucose ([18F]FDG)-PET/computed tomography (CT) scans and by evaluating changes in ventricular tachycardia episodes before and after treatment. Results: One patient with therapy refractory progressive cardiac sarcoidosis and recurrent ventricular tachycardia was treated. The cardiac sarcoidosis disease activity showed a durable regression of inflammatory disease activity from 3 months onwards. The [18F]FDG-PET/CT scan at 54 months did not show any signs of active cardiac sarcoidosis, and a state of remission was achieved. The number of sustained VT episodes was reduced by 95%. We observed that the development of moderate aortic valve regurgitation was likely irradiation-related. No other irradiation-related adverse events occurred, and the left ventricular ejection fraction remained stable. Conclusion: We report here for the first time on the beneficial and lasting effects of combined immunomodulatory low-dose whole-heart radiotherapy and high-dose stereotactic arrhythmia radioablation in a patient with therapy refractory cardiac sarcoidosis and recurrent VT.

11.
Rev Med Suisse ; 19(N° 809-10): 16-24, 2023 Jan 18.
Article in French | MEDLINE | ID: mdl-36660831

ABSTRACT

The year of 2022 was marked by many novelties in the fields of interventional cardiology, heart failure, electrophysiology, cardiac imaging, and congenital heart disease. These advances will certainly change our daily practice, on top of improving the diagnosis and treatment of many heart conditions. In addition, the European Society of Cardiology has updated its guidelines on pulmonary hypertension, ventricular arrhythmias and sudden death, cardiovascular assessment of patients undergoing non-cardiac surgery. The members of the Cardiology division of Lausanne University Hospital (CHUV) here present the publications which they considered to be the most important of the past year.


L'année 2022 a été marquée par de nombreuses nouveautés dans les domaines de la cardiologie interventionnelle, de l'insuffisance cardiaque, de l'électrophysiologie, de l'imagerie cardiaque et des cardiopathies congénitales. Ces progrès vont certainement faire évoluer notre pratique quotidienne, en plus d'améliorer le diagnostic et le traitement de nombreuses cardiopathies. Par ailleurs, la Société européenne de cardiologie a mis à jour ses recommandations portant sur l'hypertension pulmonaire, les arythmies ventriculaires et la mort subite ainsi que le bilan cardiologique avant une chirurgie non cardiaque. Les membres du Service de cardiologie du CHUV vous présentent ici les travaux qui leur ont semblé être les plus importants de l'année écoulée.


Subject(s)
Cardiology , Heart Defects, Congenital , Heart Failure , Humans , Death, Sudden, Cardiac/etiology , Death, Sudden, Cardiac/prevention & control , Arrhythmias, Cardiac/diagnosis , Arrhythmias, Cardiac/therapy , Heart Defects, Congenital/diagnosis
13.
Front Cardiovasc Med ; 9: 910693, 2022.
Article in English | MEDLINE | ID: mdl-36148076

ABSTRACT

Background: Studies suggest that performing an electrophysiological study (EPS) may be useful to identify patients with new-onset left bundle branch block (LBBB) post-TAVR at risk of atrioventricular block. However, tools to optimize the yield of such strategy are needed. We therefore aimed to investigate whether 12-lead ECG changes post-TAVR may help identify patients with abnormal EPS findings. Materials and methods: Consecutive patients with new-onset LBBB post-TAVR who underwent EPS were included. PR and QRS intervals were measured on 12-lead ECG pre-TAVR and during EPS. Abnormal EPS was defined as an HV interval > 55 ms. Results: Among 61 patients, 28 (46%) had an HV interval > 55 ms after TAVR. Post-TAVR PR interval and ΔPR (PR-post-pre-TAVR) were significantly longer in patients with prolonged HV (PR: 188 ± 38 vs. 228 ± 34 ms, p < 0.001, ΔPR: 10 ± 30 vs. 34 ± 23 ms, p = 0.001), while no difference was found in QRS duration. PR and ΔPR intervals both effectively discriminated patients with HV > 55 ms (AUC = 0.804 and 0.769, respectively; p < 0.001). A PR > 200 ms identified patients with abnormal EPS results with a sensitivity of 89% and a negative predictive value (NPV) of 88%. ΔPR ≥ 20 ms alone provided a somewhat lower sensitivity (64%) but combining both criteria (i.e., PR > 200 ms or ΔPR ≥ 20 ms) identified almost every patients with abnormal HV (sensitivity = 96%, NPV = 95%). Selecting EPS candidate based on both criteria would avoid 1/3 of exams. Conclusion: PR interval assessment may be useful to select patients with new-onset LBBB after TAVR who may benefit most from an EPS. In patients with PR ≤ 200 ms and ΔPR < 20 ms the likelihood of abnormal EPS is very low independently of QRS changes.

14.
Rev Med Suisse ; 18(783): 1048-1051, 2022 May 25.
Article in French | MEDLINE | ID: mdl-35612477

ABSTRACT

Atrial fibrillation (AF) is the most common arrhythmia encountered in adults; it is associated with a significant morbidity and mortality. Obesity is a risk factor contributing to AF occurrence. Recently, interest has focused on epicardial adipose tissue (EAT), defined as a fatty deposit located between the epicardium and the visceral pericardium. Its characteristics are distinct from classic adipose deposits: it infiltrates the epicardial myocardium and secretes cytokines, which modulate cardiomyocyte electrophysiology and cardiac remodeling. Different studies show that EAT can be an independent risk factor for AF and that EAT thickness, as measured by CT or MRI, could predict the presence, severity and recurrence of AF.


La fibrillation auriculaire (FA) est l'arythmie la plus fréquemment rencontrée chez l'adulte ; elle est associée à une morbi-mortalité importante. L'obésité est un facteur de risque contribuant à sa survenue. Récemment, l'intérêt s'est porté sur le tissu adipeux épicardique (TAE), défini comme un dépôt adipeux situé entre l'épicarde et le péricarde viscéral. Ses caractéristiques sont distinctes des dépôts adipeux classiques : il infiltre le myocarde épicardique et sécrète des cytokines modulant l'électrophysiologie des cardiomyocytes et provoquant un remodelage fibro-adipeux cardiaque. Différentes études montrent que le TAE peut être un facteur de risque indépendant de survenue de FA. L'épaisseur du TAE mesurée par CT-scan ou par IRM pourrait être utilisée comme facteur prédictif de la présence, de la gravité et de la récidive de FA.


Subject(s)
Atrial Fibrillation , Adipose Tissue , Atrial Fibrillation/epidemiology , Humans , Obesity/complications , Obesity/epidemiology , Pericardium/diagnostic imaging , Risk Factors
15.
Pacing Clin Electrophysiol ; 45(5): 658-665, 2022 05.
Article in English | MEDLINE | ID: mdl-35417049

ABSTRACT

BACKGROUND: With an increasing number of cardiac implantable electronic devices (CIEDs), there has been a paralleled increase in demand for transvenous lead extraction (TLE). Cardiac surgeons (CS) and cardiologists perform TLE; however, data comparing the two groups of operators is scarce. OBJECTIVE: We compared the outcomes of TLE performed by cardiologists and CS from six European lead extraction units. METHOD: Data was collected retrospectively of 2205 patients who had 3849 leads extracted (PROMET) between 2005 and 2018. Patient demographics and procedural outcomes were compared between the CS and cardiologist groups, using propensity score matching. A multivariate regression analysis was also performed for variables associated with 30-day mortality. RESULTS: CS performed the majority of extractions (59.8%), of leads with longer dwell times (90 [57-129 interquartile range (IQR)] vs. 62 [31-102 IQR] months, CS vs. cardiologists, p < .001) and with pre-dominantly non-infectious indications (57.4% vs. 50.2%, CS vs. cardiologists, p < .001). CS achieved a higher complete success per lead than the cardiologists (98.1% vs. 95.7%, respectively, p < .01), with a higher number of minor complications (5.51% vs. 2.1%, p < .01) and similar number of major complications (0.47% vs. 1.3%, p = .12). Thirty-day mortality was similarly low in the CS and cardiologist groups (1.76% vs. 0.94%, p = .21). Unmatched data multivariate analysis revealed infection indication (OR 6.12 [1.9-20.3], p < .01), procedure duration (OR 1.01 [1.01-1.02], p < .01) and CS operator (OR 2.67, [1.12-6.37], p = .027) were associated with 30-day mortality. CONCLUSION: TLE by CS was performed with similar safety and higher efficacy compared to cardiologists in high and medium-volume lead extraction centers.


Subject(s)
Defibrillators, Implantable , Pacemaker, Artificial , Device Removal/methods , Humans , Promethazine , Retrospective Studies , Treatment Outcome
16.
Front Cardiovasc Med ; 9: 783576, 2022.
Article in English | MEDLINE | ID: mdl-35282352

ABSTRACT

Over the last decades, the implementation of new technology in cardiac pacemakers and defibrillators as well as the increasing life expectancy have been associated with a higher incidence of transvenous lead complications over time. Variable degrees of venous stenosis at the level of the subclavian vein, the innominate trunk and the superior vena cava are reported in up to 50% of implanted patients. Importantly, the number of implanted leads seems to be the main risk factor for such complications. Extraction of abandoned or dysfunctional leads is a potential solution to overcome venous stenosis in case of device upgrades requiring additional leads, but also, in addition to venous angioplasty and stenting, to reduce symptoms related to the venous stenosis itself, i.e., the superior vena cava syndrome. This review explores the role of transvenous lead extraction procedures as therapeutical option in case of central venous disorders related to transvenous cardiac leads. We also describe the different extraction techniques available and other clinical indications for lead extractions such as lead infections. Finally, we discuss the alternative therapeutic options for cardiac stimulation or defibrillation in case of chronic venous occlusions that preclude the implant of conventional transvenous cardiac devices.

17.
Rev Med Suisse ; 18(767): 144-151, 2022 Feb 02.
Article in French | MEDLINE | ID: mdl-35107886

ABSTRACT

Significant advances have been made in 2021 in the areas of interventional cardiology, heart failure, cardiac imaging, electrophysiology and congenital heart disease. In addition to improving the screening, diagnosis and management of many heart diseases, these advances will change our daily practice. Moreover, the European Society of Cardiology has updated its guidelines on heart failure, valve disease, cardiac pacing and cardiovascular disease prevention. As in previous years, members of the Cardiology division of Lausanne University Hospital (CHUV) came together to select and present to you the papers that they considered to be the most important of the past year.


De nombreux progrès ont été réalisés en 2021 dans les domaines de la cardiologie interventionnelle, de l'insuffisance cardiaque, de l'imagerie cardiaque, de l'électrophysiologie et des cardiopathies congénitales. En plus d'améliorer le dépistage, le diagnostic et la prise en charge de nombreuses cardiopathies, ces avancées vont faire évoluer notre pratique quotidienne. Par ailleurs, la Société européenne de cardiologie a mis à jour ses recommandations portant sur l'insuffisance cardiaque, les valvulopathies, la stimulation cardiaque et la prévention des maladies cardiovasculaires. Comme les années précédentes, les membres du Service de cardiologie du CHUV se sont réunis pour sélectionner et vous présenter les travaux qui leur ont semblé être les plus importants de l'année écoulée.


Subject(s)
Cardiology , Heart Defects, Congenital , Heart Failure , Heart Failure/diagnosis , Heart Failure/therapy , Humans
18.
J Cardiovasc Magn Reson ; 24(1): 9, 2022 01 13.
Article in English | MEDLINE | ID: mdl-35022037

ABSTRACT

BACKGROUND: The use of stress perfusion-cardiovascular magnetic resonance (CMR) imaging remains limited in patients with implantable devices. The primary goal of the study was to assess the safety, image quality, and the diagnostic value of stress perfusion-CMR in patients with MR-conditional transvenous permanent pacemakers (PPM) or implantable cardioverter-defibrillators (ICD). METHODS: Consecutive patients with a transvenous PPM or ICD referred for adenosine stress-CMR were enrolled in this single-center longitudinal study. The CMR protocol was performed using a 1.5 T system according to current guidelines while all devices were put in MR-mode. Quality of cine, late-gadolinium-enhancement (LGE), and stress perfusion sequences were assessed. An ischemia burden of ≥ 1.5 segments was considered significant. We assessed the safety, image quality and the occurrence of interference of the magnetic field with the implantable device. In case of ischemia, we also assessed the correlation with the presence of significant coronary lesions on coronary angiography. RESULTS: Among 3743 perfusion-CMR examinations, 66 patients had implantable devices (1.7%). Image quality proved diagnostic in 98% of cases. No device damage or malfunction was reported immediately and at 1 year. Fifty patients were continuously paced during CMR. Heart rate and systolic blood pressure remained unchanged during adenosine stress, while diastolic blood pressure decreased (p = 0.007). Six patients (9%) had an ischemia-positive stress CMR and significant coronary stenoses were confirmed by coronary angiography in all cases. CONCLUSION: Stress perfusion-CMR is safe, allows reliable ischemia detection, and provides good diagnostic value.


Subject(s)
Defibrillators, Implantable , Myocardial Perfusion Imaging , Pacemaker, Artificial , Adenosine , Feasibility Studies , Humans , Longitudinal Studies , Magnetic Resonance Imaging , Magnetic Resonance Imaging, Cine , Magnetic Resonance Spectroscopy , Perfusion Imaging , Predictive Value of Tests
19.
Pacing Clin Electrophysiol ; 44(9): 1540-1548, 2021 Sep.
Article in English | MEDLINE | ID: mdl-34235772

ABSTRACT

BACKGROUND: Cardiac implantable electronic device (CIED) therapy contributes to an improvement in morbidity and mortality across all patient demographics. Patient age is a recognized risk factor for unfavorable outcomes in invasive procedures. This is the largest series of non-laser transvenous lead extraction (TLE) evaluating the association between patient age and procedure outcomes. METHODS: Data of 2205 (3849 leads) patients was collected retrospectively from six European TLE centers between January 2005-December 2018 in the PROMET study. Of these, 153 patients with 319 leads were excluded for incomplete data. A comparison of outcomes was performed between the age groups young [< 50 years], young intermediate [50-69 years], older intermediate [70-79 years], and octogenarian [≥80 years]. RESULTS: Infection was most common indication for TLE in the octogenarian cohort, less common in the younger population (60.1% vs. 33.2%, respectively, p < .01). High-voltage leads were extracted most frequently from young patients, less frequently from octogenarians (31.6% vs. 10%, p < .001), while the opposite was evident for pacemaker leads (p < .001). Rotational sheath use was equally prevalent across all patient groups (p = .79). Minor and major complications across all the age groups were statistically similar, as was procedural success; the 30-day mortality was most significant in the octogenarian and least in the young patients (4.9% vs. 0.4%, p = .005). Propensity matching multivariate analysis found systemic infection, lead dwell time, and patient age (p = .013, OR 1.064 [1.013-1.116]) increased risk of 30-day mortality. CONCLUSION: TLE is safe and effective across all age groups. 30-day mortality risk is significantly higher in the older patients.


Subject(s)
Device Removal/methods , Electrodes, Implanted , Adult , Age Factors , Aged , Aged, 80 and over , Europe , Female , Humans , Male , Middle Aged , Retrospective Studies
20.
Rev Med Suisse ; 17(723): 172-180, 2021 Jan 27.
Article in French | MEDLINE | ID: mdl-33507655

ABSTRACT

In 2020, new guidelines have been published by the European Society of Cardiology including those on non-ST-segment elevation acute coronary syndromes, atrial fibrillation and adult congenital heart disease. Regarding interventional cardiology, POPular TAVI opens the possibility of anti-platelet monotherapy after transcutaneous aortic valve replacement. EMPEROR-Reduced confirms the importance of SGLT2 inhibitors in the treatment of heart failure with reduced ejection fraction. Within the field of imaging, stress MRI has now become the first-line technique for the screening of coronary artery disease, demonstrating an excellent cost-benefit ratio. Finally, renin-angiotensin-aldosterone inhibitors do not appear to increase the risk of an infection by COVID-19.


L'année 2020 a été marquée par la publication de nouvelles guidelines de la Société européenne de cardiologie dont le syndrome coronarien aigu sans élévation du segment ST, la fibrillation auriculaire et les cardiopathies congénitales à l'âge adulte. En interventionnel, POPular TAVI permet d'envisager la monothérapie antithrombotique après remplacement de la valve aortique par voie transcutanée. EMPEROR-Reduced confirme l'importance des inhibiteurs du cotransporteur sodium-glucose de type 2 dans le traitement de l'insuffisance cardiaque à fraction d'éjection réduite. En imagerie, l'IRM de stress s'impose comme examen de choix pour le dépistage de la maladie coronarienne avec un rapport coût-bénéfice favorable. Enfin, les inhibiteurs du système rénine-angiotensine-aldostérone ne semblent pas augmenter le risque d'une infection au Covid-19.


Subject(s)
COVID-19 , Cardiology , Heart Defects, Congenital , Humans , SARS-CoV-2
SELECTION OF CITATIONS
SEARCH DETAIL
...