Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 19 de 19
Filter
1.
Sci Rep ; 10(1): 18916, 2020 11 03.
Article in English | MEDLINE | ID: mdl-33144662

ABSTRACT

Rocky Mountain bighorn sheep rams (Ovis canadensis canadensis) routinely conduct intraspecific combat where high energy cranial impacts are experienced. Previous studies have estimated cranial impact forces to be up to 3400 N during ramming, and prior finite element modeling studies showed the bony horncore stores 3 × more strain energy than the horn during impact. In the current study, the architecture of the porous bone within the horncore was quantified, mimicked, analyzed by finite element modeling, fabricated via additive manufacturing, and mechanically tested to determine the suitability of the novel bioinspired material architecture for use in running shoe midsoles. The iterative biomimicking design approach was able to tailor the mechanical behavior of the porous bone mimics. The approach produced 3D printed mimics that performed similarly to ethylene-vinyl acetate shoe materials in quasi-static loading. Furthermore, a quadratic relationship was discovered between impact force and stiffness in the porous bone mimics, which indicates a range of stiffness values that prevents impact force from becoming excessively high. These findings have implications for the design of novel bioinspired material architectures for minimizing impact force.


Subject(s)
Biomimetic Materials/chemistry , Horns/anatomy & histology , Sheep, Bighorn/physiology , Animals , Behavior, Animal , Biomechanical Phenomena , Finite Element Analysis , Male , Models, Biological , Polyvinyls/chemistry , Porosity , Printing, Three-Dimensional
2.
Orthop Rev (Pavia) ; 12(2): 8448, 2020 Aug 06.
Article in English | MEDLINE | ID: mdl-32922696

ABSTRACT

Due to the complex and dynamic nature of osteoarthritis (OA) and post-traumatic osteoarthritis (PTOA), animal models have been used to investigate the progression and pathogenesis of the disease. Researchers have used different experimental models to study OA and PTOA. With an emphasis on the knee joint, this review will compare and contrast the existing body of knowledge from anterior cruciate ligament transection models, meniscectomy models, combination models, as well as impact models in large animals to see how tissues respond to these different approaches to induce experimental OA and PTOA. The tissues discussed will include articular cartilage and the meniscus, with a focus on morphological, mechanical and histological assessments. The goal of this review is to demonstrate the progressive nature of OA by indicating the strong correlation between progressive tissue degeneration, change of mechanical properties, and loss of biochemical integrity and to highlight key differences between the most commonly used experimental animal models.

3.
Acta Biomater ; 88: 314-324, 2019 04 01.
Article in English | MEDLINE | ID: mdl-30825603

ABSTRACT

Controlling the phenotype of transplanted stem cells is integral to ensuring their therapeutic efficacy. Hypoxia is a known regulator of stem cell fate, the effects of which can be mimicked using hypoxia-inducible factor (HIF) prolyl hydroxylase inhibitors such as dimethyloxalylglycine (DMOG). By releasing DMOG from mesenchymal stem cell (MSC) laden alginate hydrogels, it is possible to stabilize HIF-1α and enhance its nuclear localization. This correlated with enhanced chondrogenesis and a reduction in the expression of markers associated with chondrocyte hypertrophy, as well as increased SMAD 2/3 nuclear localization in the encapsulated MSCs. In vivo, DMOG delivery significantly reduced mineralisation of the proteoglycan-rich cartilaginous tissue generated by MSCs within alginate hydrogels loaded with TGF-ß3 and BMP-2. Together these findings point to the potential of hypoxia mimicking hydrogels to control the fate of stem cells following their implantation into the body. STATEMENT OF SIGNIFICANCE: There are relatively few examples where in vivo delivery of adult stem cells has demonstrated a true therapeutic benefit. This may be attributed, at least in part, to a failure to control the fate of transplanted stem cells in vivo. In this paper we describe the development of hydrogels that mimic the effects of hypoxia on encapsulated stem cells. In vitro, these hydrogels enhance chondrogenesis of MSCs and suppress markers associated with chondrocyte hypertrophy. In an in vivo environment that otherwise supports progression along an endochondral pathway, we show that these hydrogels will instead direct mesenchymal stem cells (MSCs) to produce a more stable, cartilage-like tissue. In addition, we explore potential molecular mechanisms responsible for these phenotypic changes in MSCs.


Subject(s)
Hydrogels/pharmacology , Mesenchymal Stem Cell Transplantation , Mesenchymal Stem Cells/cytology , Alginates/chemistry , Amino Acids, Dicarboxylic/pharmacology , Animals , Bone Morphogenetic Protein 2/pharmacology , Cell Hypoxia/drug effects , Cell Nucleus/drug effects , Cell Nucleus/metabolism , Chondrogenesis/drug effects , Gene Expression Regulation/drug effects , Hypertrophy , Hypoxia-Inducible Factor 1, alpha Subunit/metabolism , Mesenchymal Stem Cells/drug effects , Mice, Nude , Osteogenesis/drug effects , Osteogenesis/genetics , Protein Stability/drug effects , Protein Transport/drug effects , Smad Proteins/metabolism , Swine , Transforming Growth Factor beta3/pharmacology
4.
Prosthet Orthot Int ; 42(5): 511-517, 2018 Oct.
Article in English | MEDLINE | ID: mdl-29623811

ABSTRACT

BACKGROUND: Designed by Dr. Sethi, the Jaipur Foot prosthesis is ideally suited for amputees in developing countries as it utilizes locally sourced, biodegradable, inexpensive materials and is focused on affordability and functionality. To date, however, no data have been reported on the material properties of the foot components. OBJECTIVES: The goal of this work was to evaluate mechanical properties of the Jaipur Foot components to guide foot design and manufacturing and reduce weight. STUDY DESIGN: Experimental. METHODS: Mechanical testing was conducted on two types of woods (ardu and cheed), microcellular rubber, tire cord, cushion compound, tread compound, and skin-colored rubber. Each material was subjected to testing in either tension or compression based on its location and function in the foot. Samples were tested before and after vulcanization. Two-sample t-tests were used to assess statistical differences. RESULTS: Cheed compressed perpendicular to the grain had a significantly higher modulus of elasticity than ardu ( p < 0.05); however, cheed had a higher density. Vulcanization significantly increased the modulus of skin-colored rubber, cushion compound, and tread compound ( p < 0.05) and decreased the moduli of both microcellular rubber and tire cord ( p < 0.05). CONCLUSION: The material property results from this study provide information for computer modeling to assess material construction on overall foot mechanics for design optimization. Ardu wood was ideal based on the desire to reduce weight, and the tire cord properties serve well to hold the foot together. Clinical relevance With new knowledge on the material properties of the components of the Jaipur Foot, future design modifications and standardized fabrication can be realized, making the Jaipur Foot more available on a global scale.


Subject(s)
Artificial Limbs , Compressive Strength , Foot , Materials Testing , Tensile Strength , Elastic Modulus , Humans , Prosthesis Design , Prosthesis Failure , Weight-Bearing
5.
J Orthop Res ; 35(3): 486-495, 2017 03.
Article in English | MEDLINE | ID: mdl-27129040

ABSTRACT

The objective of this study was to compare longitudinal results from two models of combined anterior cruciate ligament (ACL) and meniscal injury. A modified ACL transection (mACLT) model and a traumatic impact (ACLF) model were used to create an ACL rupture and acute meniscal damage in a Flemish Giant animal model. The animals were euthanized at time points of 4, 8, or 12 weeks. The menisci were assessed for equilibrium and instantaneous compressive modulus, as well as glycosaminoglycan (GAG) coverage. The articular cartilage was mechanically assessed for thickness, matrix modulus, fiber modulus, and permeability. Articular cartilage GAG coverage, fissuring, tidemark integrity, and subchondral bone thickness were measured. Both models resulted in damage indicative of osteoarthritis, including decreased meniscal mechanics and GAG coverage, increased permeability and fissuring of articular cartilage, and decreased GAG coverage. The mACLT model had an early and lasting effect on the menisci mechanics and GAG coverage, while cartilage damage was not significantly affected until 12 weeks. The ACLF model resulted in an earlier change of articular cartilage GAG coverage and fissuring in both the 8 and 12 week groups. The menisci were only significantly affected at the 12 week time point in the ACLF model. We concluded the progression of post traumatic osteoarthritis was dependent on injury modality: a point to be considered in future investigations. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 35:486-495, 2017.


Subject(s)
Anterior Cruciate Ligament Injuries/complications , Cartilage, Articular/pathology , Disease Models, Animal , Osteoarthritis, Knee/etiology , Tibial Meniscus Injuries/complications , Animals , Anterior Cruciate Ligament Injuries/pathology , Female , Male , Osteoarthritis, Knee/pathology , Rabbits , Tibial Meniscus Injuries/pathology
6.
J Biomech ; 49(13): 3056-3060, 2016 09 06.
Article in English | MEDLINE | ID: mdl-27425557

ABSTRACT

The passive tensile properties of skeletal muscle play a key role in its physiological function. Previous research has identified conflicting reports of muscle transverse isotropy, with some data suggesting the longitudinal direction is stiffest, while others show the transverse direction is stiffest. Accurate constitutive models of skeletal muscle must be employed to provide correct recommendations for and observations of clinical methods. The goal of this work was to identify transversely isotropic tensile muscle properties as a function of post mortem handling. Six pairs of tibialis anterior muscles were harvested from Giant Flemish rabbits and split into two groups: fresh testing (within four hours post mortem), and non-fresh testing (subject to delayed testing and a freeze/thaw cycle). Longitudinal and transverse samples were removed from each muscle and tested to identify tensile modulus and relaxation behavior. Longitudinal non-fresh samples exhibited a higher initial modulus value and faster relaxation than longitudinal fresh, transverse fresh, and transverse rigor samples (p<0.05), while longitudinal fresh samples were less stiff at lower strain levels than longitudinal non-fresh, transverse fresh, and transverse non-fresh samples (p<0.05), but exhibited more nonlinear behavior. While fresh skeletal muscle exhibits a higher transverse modulus than longitudinal modulus, discrepancies in previously published data may be the result of a number of differences in experimental protocol. Constitutive modeling of fresh muscle should reflect these data by identifying the material as truly transversely isotropic and not as an isotropic matrix reinforced with fibers.


Subject(s)
Muscle, Skeletal/cytology , Specimen Handling/methods , Tensile Strength , Animals , Biomechanical Phenomena , Muscle, Skeletal/physiology , Rabbits , Stress, Mechanical
7.
J Exp Orthop ; 3(1): 10, 2016 Dec.
Article in English | MEDLINE | ID: mdl-26928558

ABSTRACT

BACKGROUND: The purpose of this study was to quantify the meniscal root anatomy of the New Zealand white rabbit to better understand this animal model for future in vitro and in vivo joint degeneration studies. METHODS: Ten non-paired fresh frozen New Zealand white rabbit knee stifle joints were carefully disarticulated for this study. Measurements were made for all bony landmarks and ligamentous structure attachment sites on the tibial plateau. The following soft tissue structures were consistently identified in the rabbit stifle joint: the anterior root attachment of the lateral meniscus, the anterior root attachment of the medial meniscus, the anterior cruciate ligament, the posterior root attachment of the medial meniscus, the ligament of Wrisberg, the posterior cruciate ligament, and the posterior meniscotibial ligament. The following bony landmarks were consistently identified: the extensor digitorum longus groove, the medial tibial eminence, the center of the tibial tuberosity, and the lateral tibial eminence. RESULTS: The center of the anterior cruciate ligament and the medial tibial eminence apex were found to be 3.4 ± 0.3 mm (2.9-3.6) and 6.1 ± 0.6 mm (5.1-7.0) respectively from the center of the medical anterior root attachment. The center of the anterior cruciate ligament and the lateral tibial eminence apex were found to be 2.1 ± 0.5 mm (1.2-2.7) and 7.0 ± 0.6 mm (6.4-8.2) respectively from the center of the lateral anterior root attachment. The center of the posterior cruciate ligament and the medial tibial eminence apex were found to be 2.0 ± 0.7 mm (0.5-2.6) and 1.8 ± 0.4 mm (1.2-2.4) respectively from the center of the medial posterior root attachment. CONCLUSIONS: This study augments our understanding of the comparative anatomy of the rabbit stifle joint. This information will be useful for future biomechanical, surgical, and in vitro studies utilizing the rabbit stifle as a model for human knee joint degenerative diseases.

8.
J Biomech ; 48(8): 1341-2, 2015 Jun 01.
Article in English | MEDLINE | ID: mdl-25911253
9.
Acta Biomater ; 9(5): 6322-9, 2013 May.
Article in English | MEDLINE | ID: mdl-23385217

ABSTRACT

Meniscus efficacy at promoting joint congruity and preventing osteoarthritis hinges on enthesis integrity. Gross-scale tensile testing, histomorphometry and magnetic resonance imaging reveal significant differences between the four attachments, implying that each must endure a unique mechanical environment, which dictates their structure. However, little data exists to elucidate how these interfaces have adapted to their complex loading environment, particularly on a relevant scale, as the enthesis transitions through several unique zones in less than a millimeter. In our study we leveraged nanoindentation to determine viscoelastic material properties through the transition zones. Additionally, we employed histological techniques to evaluate the enthesis structure, including collagen organization and interdigitation morphometry. Mechanical evaluation revealed the medial posterior insertion site to be significantly more compliant than others. Collagen fiber orientation and dispersion as well as interdigitation morphometry were significantly different between attachments sites. These findings are clinically relevant as a disproportionate amount of enthesis failure occurs in the medial posterior attachment. Also, meniscal enthesis structure and function will need to be considered in future reparative and replacement strategies in order to recreate native meniscus mechanics and prevent osteoarthritis propagation.


Subject(s)
Evaluation Studies as Topic , Knee Joint/anatomy & histology , Menisci, Tibial/anatomy & histology , Humans , Knee Joint/physiology
10.
Acta Biomater ; 9(5): 6624-9, 2013 May.
Article in English | MEDLINE | ID: mdl-23321302

ABSTRACT

Menisci are two crescent shaped fibrocartilaginous structures that provide fundamental load distribution and support within the knee joint. Their unique shape transmits axial stresses (i.e. "body force") into hoop or radial stresses. The menisci are primarily an inhomogeneous aggregate of glycosaminoglycans (GAGs) supporting bulk compression and type I collagen fibrils sustaining tension. It has been shown that the superficial meniscal layers are functionally homogeneous throughout the three distinct regions (anterior, central and posterior) using a 300 µm diameter spherical indenter tip, but the deep zone of the meniscus has yet to be mechanically characterized at this scale. Furthermore, the distribution and content of GAG throughout the human meniscal cross-section have not been examined. This study investigated the mechanical properties, via indentation, of the human deep zone meniscus among three regions of the lateral and medial menisci. The distribution of GAGs through the cross-section was also documented. Results for the deep zone of the meniscus showed the medial posterior region to have a significantly greater instantaneous elastic modulus than the central region. No significant differences in the equilibrium modulus were seen when comparing regions or the hemijoint. Histological results revealed that GAGs are not present until at least ~600 µm from the meniscal surface. Understanding the role and distribution of GAG within the human meniscus in conjunction with the material properties of the meniscus will aid in the design of tissue engineered meniscal replacements.


Subject(s)
Glycosaminoglycans/metabolism , Menisci, Tibial/metabolism , Aged , Glycosaminoglycans/analysis , Humans , Materials Testing , Middle Aged
11.
J Mech Behav Biomed Mater ; 17: 290-5, 2013 Jan.
Article in English | MEDLINE | ID: mdl-23127626

ABSTRACT

Skeletal muscle tissue provides support and mobility of the musculoskeletal system. Numerical modeling of muscle tissue aids in understanding disease pathophysiology, however, the effectiveness is dependent on accurately accounting for various tissue phenomena. Muscle modeling is made difficult due to the multitude of constituents that contribute to elastic and viscous mechanisms. Often, deterministic single fiber or fiber bundle studies are undertaken to examine these contributions. However, examination of whole, intact and structurally altered tissue and comparison to findings at the myofibril scale can help elucidate tissue mechanics. Stress relaxation tests at 10% strain were performed on 28 New Zealand White rabbit's tibialis anterior muscles for whole, intact muscle and sub-sectioned muscle samples. Additionally, to aid in examining viscous effects, sub groups were tested with and without a phosphate buffered saline bath. The steady-state elastic modulus was not significantly different between groups. Interestingly, sectioning did result in a negative Poisson's ratio following tensile loading. Additionally, sectioning resulted in altering the viscous tissue response as the time to reach steady-state was significantly faster than whole muscle samples (p<0.05), as well as the linear relaxation rate from 0 to 0.1 (p<0.01), 1 to 10 (p<0.05), and 10 to 100 s (p<0.05). Bathing tissue resulted in a significantly greater amount of percent stress relaxation for whole muscle (p<0.01). These findings provide new insight into the differing mechanical characteristics of whole and sectioned muscle tissue.


Subject(s)
Immersion , Lower Extremity , Materials Testing/methods , Mechanical Phenomena , Muscle, Skeletal , Animals , Biomechanical Phenomena , Extracellular Matrix/metabolism , Muscle, Skeletal/cytology , Rabbits , Stress, Mechanical , Time Factors
12.
J Mech Behav Biomed Mater ; 4(8): 2024-30, 2011 Nov.
Article in English | MEDLINE | ID: mdl-22098902

ABSTRACT

Imaging of meniscal tissue reveals an extracellular matrix comprised of collagen fibrils arranged in circumferential bundles and radially aligned tie fibers, implicating structural material anisotropy. Biochemical analyses demonstrate regional disparities of proteoglycan content throughout the meniscal body, a constituent known to affect the shearing response of fibrocartilagenous tissue. Despite this phenomenological evidence and previous mechanical testing implicating otherwise, the meniscus if often modeled as a homogeneous, transversely isotropic material with little regard for regional specificity and material properties. The aim of this investigation was to determine if shear stress response homogeneity and directionality exists in and between bovine menisci with respect to anatomical location (medial and lateral), region (anterior, central, and posterior) and fiber orientation (parallel and perpendicular). Meniscus explants were subjected to lap shear strain at 0.002 s(-1) with the circumferential collagen fibers oriented parallel or perpendicular to the loading axis. Comparisons were made using a piecewise linear elastic analysis. The toe region shear modulus was calculated from the first observed linear region, between 3% and 13% strain and the extended shear modulus was established after 80% of the maximum shear strain. The posterior region was significantly different than the central for the extended shear modulus, correlating with known proteoglycan distribution. Observed shearing anisotropy led to the use of an anisotropic hyperelastic model based on a two-fiber family composite, previously used for arterial walls. The chosen model provided an excellent fit to the sample population for each region. These data can be utilized in the advancement of finite element modeling as well as biomimetic tissue engineered constructs.


Subject(s)
Menisci, Tibial/cytology , Shear Strength , Animals , Anisotropy , Biomechanical Phenomena , Cattle , Collagen/metabolism , Extracellular Matrix/metabolism , Feasibility Studies , Menisci, Tibial/metabolism , Models, Biological , Stress, Mechanical
13.
Connect Tissue Res ; 51(5): 327-36, 2010 Oct.
Article in English | MEDLINE | ID: mdl-20388017

ABSTRACT

Qualitative analysis of meniscal attachments from five human knees was completed using scanning electron microscopy (SEM). In addition, quantitative analysis to determine the collagen crimping angle and length in each attachment was done. Morphological differences were revealed between the distinct zones of the attachments from the meniscus transition to the bony insertion. Collagen fibers near to the meniscus appeared inhomogeneous in a radial cross-section view. The sheath surrounding the fibers seemed loose compared with the membrane wrapping around the fibers in the menisci. The midsubstance of human meniscal attachments was composed of collagen fibers running parallel to the longitudinal axis, with a few fibers running obliquely, and others transversely. The bony insertion showed that the crimping pattern vanishes as the collagen fibers approach the fibrocartilagenous enthesis. There were no differences between attachments for crimping angle or length. Collagen crimping angles for all attachments were similar with values of approximately 22°. Crimp length values tended to be smaller for the medial attachments (MA: 4.76 ± 1.95 µm; MP: 3.72 ± 2.31 µm) and higher for the lateral (LA: 6.49 ± 2.34 µm, LP: 6.91 ± 2.29 µm). SEM was demonstrated to be an effective method for revealing the morphology of fibrous connective tissue. The data of collagen fiber length and angle found in this study will allow for better development of microstructural models of meniscal attachments. This study will help to better understand the relation between the morphology and the architecture of collagen and the mechanical behavior of meniscal attachments.


Subject(s)
Collagen/ultrastructure , Connective Tissue/ultrastructure , Knee Joint/ultrastructure , Menisci, Tibial/ultrastructure , Microscopy, Electron, Scanning/methods , Aged , Female , Fibrocartilage/ultrastructure , Humans , Ligaments/ultrastructure , Male , Middle Aged , Range of Motion, Articular , Stress, Mechanical , Tibia/ultrastructure
14.
J Surg Res ; 164(2): 234-41, 2010 Dec.
Article in English | MEDLINE | ID: mdl-19577765

ABSTRACT

BACKGROUND: Injury patterns of the meniscus following impact trauma resulting in anterior cruciate ligament (ACL) rupture are not well understood. This study explored the spatial and temporal distribution of meniscal tears in a novel in vivo lapine model. METHODS: Skeletally mature Flemish Giant rabbits were subjected to either tibiofemoral impaction resulting in ACL rupture or surgical ACL transection. Meniscal damage was assessed acutely and after 12 wk for traumatically torn, and after 12 wk in ACL transected animals. Morphological grading was assessed using previously established criteria, and descriptions of meniscal damage were diagnosed by a Board certified orthopedist. Histological assessment was also made on 12 wk traumatically torn and ACL transected animals using Fast-Green/Safranin-O staining. RESULTS: Traumatic ACL rupture resulted in acute tears predominately in the lateral menisci. Animals subjected to both surgical transection and traumatic ACL rupture experienced degradation of the lateral and medial menisci 12 wk after injury. However, traumatic ACL rupture resulted in acute lateral damage and chronic degradation of the menisci, as well as more severe degradation of the menisci 12 wk after injury. CONCLUSIONS: This study showed that unconstrained high-intensity impacts on the tibiofemoral joint lead to meniscal damage in conjunction with ACL ruptures. Both acute and chronic changes to the menisci following traumatic impaction were observed. This research has implications for the future use of lapine models for osteoarthritis, as it incorporates traumatic loading as a more realistic mode contributing to the progression of osteoarthritis (OA) compared to surgically transected models.


Subject(s)
Anterior Cruciate Ligament Injuries , Menisci, Tibial/pathology , Osteoarthritis/surgery , Animals , Disease Models, Animal , Femur/injuries , Femur/pathology , Osteoarthritis/complications , Osteoarthritis/pathology , Rabbits , Rupture, Spontaneous/etiology , Tibia/injuries , Tibia/pathology , Tibial Meniscus Injuries , Weight-Bearing
15.
Ann Biomed Eng ; 36(1): 123-31, 2008 Jan.
Article in English | MEDLINE | ID: mdl-17999192

ABSTRACT

Little quantitative data is available on the structure of meniscal attachments. Therefore, as an aid to designing meniscal replacements as well as a possible explanation for mechanical behavior, this study was designed to further the knowledge of the microstructure and biochemistry of native meniscal attachments. Bovine medial meniscal attachments (the external ligamentous portion as well as the transition zones at the bony insertion) were removed and prepared for microstructural evaluation. After embedding in paraffin, the samples were sliced on a microtome and stained for quantitative analysis. The anterior and posterior insertion sites are known to contain three zones: subchondral bone, calcified fibrocartilage, and uncalcified fibrocartilage. Additionally, others have shown that the anterior insertion site contains a ligamentous zone. The insertion zones were further divided into proximal, middle, and distal zones. The posterior attachment's insertion site had a significantly greater thickness of interdigitations, subchondral bone, uncalcified fibrocartilage, and calcified fibrocartilage zone thickness compared to the anterior attachment insertion. The anterior attachment's insertion had the greatest GAG fraction in each zone when compared to the posterior attachment's insertion. GAG fraction decreased from the meniscus to the subchondral bone. Both GAG fraction and normalized thickness varied within a given zone, decreasing from the distal to proximal regions in both the anterior and posterior attachments' insertion zones. Crimp frequency of the collagen fibrils in the external ligamentous portion of the tissue was homogeneous along the length. The findings from this study agree with previously published material property data on the medial meniscal attachments, and could be used in the future to design methods of attachment for tissue engineered replacement menisci.


Subject(s)
Collagen/metabolism , Collagen/ultrastructure , Glycosaminoglycans/metabolism , Menisci, Tibial/cytology , Menisci, Tibial/physiology , Animals , Cattle , In Vitro Techniques , Tissue Distribution
16.
J Biomech ; 40(12): 2655-62, 2007.
Article in English | MEDLINE | ID: mdl-17359982

ABSTRACT

The menisci are frequently injured due to both degeneration and traumatic tearing. It has been suggested that the success of a meniscal replacement is dependent on several factors, one of which is the secure fixation and firm attachment of the replacement to the tibial plateau. Therefore, the objectives of the current study were to (1) determine the failure properties of the meniscal horn attachments, and (2) determine the strain distribution over their surfaces. Eight bovine knee joints were used to study the mechanical response of the meniscal attachments. Three meniscal attachments from one knee of each animal were tested in uniaxial tension at 2%/s to determine the load deformation response. During the tests, the samples were marked and local strain distributions were determined with a video extensometer. The linear modulus of the medial anterior attachment (154+/-134 MPa) was significantly less than both the medial posterior (248+/-179 MPa, p=0.0111) and the lateral anterior attachment (281+/-214 MPa, p=0.0007). Likewise, the ultimate strain for the medial anterior attachments (13.5+/-8.8%) was significantly less than the medial posterior (23+/-13%, p<0.0001) and the lateral anterior attachment (20.3+/-11.1%, p=0.0033). There were no significant differences in the structural properties or ultimate stress between the meniscal attachments (p>0.05). No significant differences in ultimate strain or moduli across the surface of the attachments were noted. Based on the data obtained, a meniscal replacement would need different moduli for each of the different attachments. However, the attachments appear to be homogeneous.


Subject(s)
Knee Injuries/physiopathology , Menisci, Tibial/physiopathology , Animals , Cattle , Ligaments, Articular , Stress, Mechanical , Tensile Strength
17.
J Biomech Eng ; 128(1): 115-23, 2006 Feb.
Article in English | MEDLINE | ID: mdl-16532624

ABSTRACT

The goal of this study is to quantify changes in knee joint contact behavior following varying degrees of the medial partial meniscectomy. A previously validated 3D finite element model was used to simulate 11 different meniscectomies. The accompanying changes in the contact pressure on the superior surface of the menisci and tibial plateau were quantified as was the axial strain in the menisci and articular cartilage. The percentage of medial meniscus removed was linearly correlated with maximum contact pressure, mean contact pressure, and contact area. The lateral hemi-joint was minimally affected by the simulated medial meniscectomies. The location of maximum strain and location of maximum contact pressure did not change with varying degrees of partial medial meniscectomy. When 60% of the medial meniscus was removed, contact pressures increased 65% on the remaining medial meniscus and 55% on the medial tibial plateau. These data will be helpful for assessing potential complications with the surgical treatment of meniscal tears. Additionally, these data provide insight into the role of mechanical loading in the etiology of post-meniscectomy osteoarthritis.


Subject(s)
Imaging, Three-Dimensional/methods , Knee Joint/physiopathology , Knee Joint/surgery , Menisci, Tibial/physiology , Menisci, Tibial/surgery , Models, Biological , Surgery, Computer-Assisted/methods , Arthroplasty/methods , Computer Simulation , Friction , Humans , Pressure , Prognosis , Surface Properties , Treatment Outcome
18.
Article in English | MEDLINE | ID: mdl-12623433

ABSTRACT

Mechanical circulatory support (MCS) devices are blood pumps that support or replace the function of the native heart. It is important to minimize the material stresses in the flexing blood sac or diaphragm in order to increase the duration of support these devices can provide. An axisymmetric finite element model of a pusherplate blood pump was constructed to evaluate the effect of various design parameters on the material stresses in a segmented poly(ether polyurethane urea) seamless blood sac. The design parameters of interest were the sac thickness, pump case wall taper, and radius of the sac between the pusherplate and pump case wall. The analysis involved a quasi-static analysis of the systolic ejection phase of the pump. The finite element solution suggested that the principal stresses and strains increased almost linearly with sac thickness. The pump case wall taper had the largest effect; decreasing the peak principal stresses by approximately 35% when the pump case was straight versus tapered. Lastly, the model demonstrated that the radius of the blood sac between the pusherplate and pump case wall had little or no effect on the magnitude of the blood sac stresses. Therefore, this study suggests that in order to minimize the stresses in a blood sac of a pusherplate blood pump, a straight pump case should be chosen with the thinnest sac.


Subject(s)
Computer-Aided Design , Equipment Design/methods , Equipment Failure Analysis/methods , Heart-Assist Devices , Models, Theoretical , Computer Simulation , Elasticity , Finite Element Analysis , Motion , Sensitivity and Specificity
19.
J Biomech Eng ; 124(3): 273-80, 2002 Jun.
Article in English | MEDLINE | ID: mdl-12071261

ABSTRACT

As a step towards developing a finite element model of the knee that can be used to study how the variables associated with a meniscal replacement affect tibio-femoral contact, the goals of this study were 1) to develop a geometrically accurate three-dimensional solid model of the knee joint with special attention given to the menisci and articular cartilage, 2) to determine to what extent bony deformations affect contact behavior, and 3) to determine whether constraining rotations other than flexion/extension affects the contact behavior of the joint during compressive loading. The model included both the cortical and trabecular bone of the femur and tibia, articular cartilage of the femoral condyles and tibial plateau, both the medial and lateral menisci with their horn attachments, the transverse ligament, the anterior cruciate ligament, and the medial collateral ligament. The solid models for the menisci and articular cartilage were created from surface scans provided by a noncontacting, laser-based, three-dimensional coordinate digitizing system with an root mean squared error (RMSE) of less than 8 microns. Solid models of both the tibia and femur were created from CT images, except for the most proximal surface of the tibia and most distal surface of the femur which were created with the three-dimensional coordinate digitizing system. The constitutive relation of the menisci treated the tissue as transversely isotropic and linearly elastic. Under the application of an 800 N compressive load at 0 degrees of flexion, six contact variables in each compartment (ie., medial and lateral) were computed including maximum pressure, mean pressure, contact area, total contact force, and coordinates of the center of pressure. Convergence of the finite element solution was studied using three mesh sizes ranging from an average element size of 5 mm by 5 mm to 1 mm by 1 mm. The solution was considered converged for an average element size of 2 mm by 2 mm. Using this mesh size, finite element solutions for rigid versus deformable bones indicated that none of the contact variables changed by more than 2% when the femur and tibia were treated as rigid. However, differences in contact variables as large as 19% occurred when rotations other than flexion/extension were constrained. The largest difference was in the maximum pressure. Among the principal conclusions of the study are that accurate finite element solutions of tibio-femoral contact behavior can be obtained by treating the bones as rigid. However, unrealistic constraints on rotations other than flexion/extension can result in relatively large errors in contact variables.


Subject(s)
Cartilage, Articular/physiology , Femur/physiology , Knee Joint/physiology , Ligaments, Articular/physiology , Models, Biological , Tibia/physiology , Adult , Anterior Cruciate Ligament/physiology , Cadaver , Collateral Ligaments/physiology , Computer Simulation , Elasticity , Finite Element Analysis , Humans , Male , Menisci, Tibial/physiology , Nonlinear Dynamics , Pressure , Range of Motion, Articular/physiology , Stress, Mechanical , Weight-Bearing
SELECTION OF CITATIONS
SEARCH DETAIL
...