Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add more filters










Database
Language
Publication year range
1.
Guang Pu Xue Yu Guang Pu Fen Xi ; 36(3): 817-22, 2016 Mar.
Article in Chinese | MEDLINE | ID: mdl-27400530

ABSTRACT

In order to investigate the emission enhancement mechanisms of reheating Double Pulse Laser-Induced Breakdown Spectroscopy (DP-LIBS), single pulse LIBS (SP-LIBS) and reheating DP-LIBS were carried out on an alloy steel sample respectively. The plasma emission was collected by an Echelle spectrometer with high resolution, while the plasma structure was monitored via fast-photography. The temporal and spatial evolutio ns of the plasma generated by SP-LIBS and reheating DP-LIBS were being studied. It is found that the plasma temperature in reheating DP-LIBS was higher than that of SP-LIBS, and there was a turning point for the decay rate of plasma temperature in reheating DP-LIBS when the delay time was equal to the interpulse time of DP-LIBS. Moreover, the inte nsity of the plasma image was increased by reheating DP-LIBS, and the height and width of the central region of the plasma were increased about 23.5% and 15.1% respectively. The results of spatial distribution showed that the intensity of Fe II and N I lines in the plasma were obviously enhanced by reheating DP-LIBS when the distance from the sample surface was larger than 0.6 mm. While the intensity enhancement for Fe I lines were little, even in some positio ns the intensity of Fe I lines decreased. The plasma temperature of double-pulse configuration was about 2 000 K higher than that of SP-LIBS, and a larger hot region in the plasma was generated. It is evidenced that the emission enhancement mechanisms in reheating DP-LIBS is that the second laser pulse re-excited the plasma induced by the first laser pulse, and the higher plasma temperature resulted from the re-exciting process.

2.
Guang Pu Xue Yu Guang Pu Fen Xi ; 34(9): 2523-8, 2014 Sep.
Article in Chinese | MEDLINE | ID: mdl-25532357

ABSTRACT

In order to overcome the influence of self-absorption on quantitative analysis, the optimizing process of very fast simulated annealing algorithm was studied. According to basic theory of plasma emission spectrum, a new algorithm for self-absorpton correction based on multi-particles spectra was proposed, and the algorithm flowchart was given. With the self-absorption correction algorithm mentioned above, the spectra of refining slag and blast furnace slag were corrected. The effect of self-ab sorption correction on the quantitative analysis results was analyzed based on calibration free method. Comparison of Boltzmann plots before and after self-absorption correction indicated that the plasma temperatures calculated with spectra after self-absorption correction tended to be uniform, and remained stable around 11,600 K. The Boltzmann plots constructed with plasma spectra of the same particle after self-absorption correction indicated that the intercepts were almost the same except for one group data. With calibration free method and spectra after self-absorption correction, the contents of components in slag were analyzed. For refining slag, quantitative analysis precision of MgO was low. If ignoring the existence of MgO, the relative errors of quantitative analysis results of CaO, Al2 O3 and SiOs were much smaller. For blast furnace slag in which the content of MgO was 8.49%, the relative error of quantitative analysis result of Al2 O3 was 2.38%, which was the smallest. And the relative error of quantitative analysis result of MgO was 28.27%, which was still the biggest.

3.
Guang Pu Xue Yu Guang Pu Fen Xi ; 31(9): 2546-51, 2011 Sep.
Article in Chinese | MEDLINE | ID: mdl-22097868

ABSTRACT

Quantitative analysis of trace elements such as manganese and chromium in steel was performed employing laser-induced breakdown spectroscopy (LIBS) technique in the present paper. The experimental measurements indicate that the optimal delay, focal plane and detecting position from the sample surface are 2 micros, -3.5 mm and 1.5 mm,respectively. Mn I: 403.07 nm and Cr I : 427.48 nm were selected as the analytical lines and their contents in the target steel sample were analyzed with traditional quantitative analysis and internal standard methods. Comparison of the results with two kinds of quantitatively analytical methods show that the coefficients of determination gained by internal standard method are 0.998 and 0.979 which are much better than the results obtained by traditional quantitative analysis method. According to the established calibration curve by internal standard method the detection limits of manganese and chromium calculated are 0.005% and 0.040 6%, respectively.

4.
Guang Pu Xue Yu Guang Pu Fen Xi ; 31(12): 3289-93, 2011 Dec.
Article in Chinese | MEDLINE | ID: mdl-22295779

ABSTRACT

Calibration-free laser induced breakdown spectroscopy (CF-LIBS) was employed for the quantitative analysis of slag. Nd:YAG laser ablation was performed in air. The laser-induced plasma emission was measured by an Echelle spectrometer equipped with an ICCD. The plasma temperature and electron number density were determined from Boltzmann plots and a Ca I line width, respectively. The assumption of local thermal equilibrium was validated by the Ne criterion. The concentration of oxides was obtained from the concentration of elements by using stoichiometric relation. The calculated oxide concentrations were compared with those obtained by XRF. The relative errors of major elements were less than 15%. The results indicate that this method can be employed for the analysis of major elements in multi-component complex materials without certified reference.

5.
Guang Pu Xue Yu Guang Pu Fen Xi ; 29(10): 2593-6, 2009 Oct.
Article in Chinese | MEDLINE | ID: mdl-20038015

ABSTRACT

Oxygen is a widely used important gas in the industrial process. It is very meaningful to on-line monitor the oxygen concentration for the enhancement of combustion efficiency and reduction in environmental pollution. Tunable diode laser absorption spectroscopy (TDLAS) is a highly sensitive, highly selective and fast time response trace gas detection technique. With the features of tunability and narrow linewidth of distributed feedback (DFB) diode laser and by precisely tuning the laser output wavelength to a single isolated absorption line of the gas, TDLAS technique can be utilized to accurately implement gas concentration measurement with very high sensitivity. In the present paper, the authors used a DFB laser was used as the light source, and by employing wavelength modulation method and measuring the second harmonic signal of one absorption line near 760 nm of oxygen molecule, the authors built a system for online monitoring of oxygen concentration. The characteristics of the system are as follows: the scope of detection is 0.01%-20%; detection accuracy is 0.1%, long term stability is 1%.

6.
Guang Pu Xue Yu Guang Pu Fen Xi ; 26(7): 1190-4, 2006 Jul.
Article in Chinese | MEDLINE | ID: mdl-17020018

ABSTRACT

Tunable diode laser absorption spectroscopy has been applied in the fields of atmospheric chemistry and monitoring pollutant gases as a new method of measuring trace gases. The technique of remote sensing of CO and CO2 at 760 mm Hg pressure with tunable diode laser absorption spectroscopy in the near-infrared region is introduced. And the relationship between the second-harmonic spectrum of CO2 in Lorentzian line shape and the modulation amplitude is also presented.

SELECTION OF CITATIONS
SEARCH DETAIL
...