Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 12 de 12
Filter
Add more filters










Publication year range
1.
Article in English | MEDLINE | ID: mdl-38671153

ABSTRACT

To provide reference and theoretical guidance for establishing human body dynamics models and studying biomechanical vibration behavior, this study aimed to develop and verify a computational model of a three-dimensional seated human body with detailed anatomical structure under complex biomechanical characteristics to investigate dynamic characteristics and internal vibration behaviors of the human body. Fifty modes of a seated human body were extracted by modal method. The intervertebral disc and head motions under uniaxial white noise excitation (between 0 and 20 Hz at 1.0, 0.5 and 0.5 m/s2 r.m.s. for vertical, fore-aft and lateral direction, respectively) were computed by random response analysis method. It was found that there were many modes of the seated human body in the low-frequency range, and the modes that had a great impact on seated human vibration were mainly distributed below 13 Hz. The responses of different positions of the spine varied greatly under the fore-aft and lateral excitation, but the maximum stress was distributed in the lumbar under different excitations, which could explain why drivers were prone to lower back pain after prolonged driving. Moreover, there was a large vibration coupling between the vertical and fore-aft direction of an upright seated human body, while the vibration couplings between the lateral and other directions were very small. Overall, the study could provide new insights into not only the overall dynamic characteristics of the human body, but also the internal local motion and biomechanical characteristics under different excitations.

2.
World Neurosurg ; 185: e431-e441, 2024 May.
Article in English | MEDLINE | ID: mdl-38360209

ABSTRACT

OBJECTIVE: To investigate the influence of sacroiliac interosseous ligament tension and laxity on the biomechanics of the lumbar spine. METHODS: A static analysis of a three-dimensional finite element model of the Lumbar-Pelvic is conducted to verify the model's effectiveness. Adjusting the sacroiliac ligament's elasticity modulus under a 10Nm lumbar flexion/extension moment, it simulates ligament tension/laxity to calculate vertebrae displacements, intervertebral disc stress and deformation, nucleus pulposus pressure, facet joint force, and ligament stress. RESULTS: With the elastic modulus of the sacroiliac ligament changing by +50%, -50%, and -90%, the angular displacement of vertebra 3 in forward flexion changes by +1.64%, -4.84%, and -42.3%, and the line displacements change by +5.7%, -16.4%, and -144.9%, respectively; and the angular displacements in backward extension change by +0.2%, -0.6%, -5.9% and the line displacements change by +5.5%, -14.3%, and -125.8%. However, the angular displacement and center distance between adjacent vertebrae do not change, leading to no change in the maximum stress of the intervertebral disc and the maximum pressure in the nucleus pulposus. Flexion and extension directly affect the deformation and stress magnitude and distribution in the lumbar spine. CONCLUSIONS: While sacroiliac interosseous ligament laxity and tension have little effect on disc deformation and stress, and nucleus pulposus pressure, they reduce the stability of the lumbar-sacral vertebrae. In a forward flexion state, the lumbar ligaments bear a large load and are prone to laxity, thereby increasing the risk of lumbar injury.


Subject(s)
Finite Element Analysis , Ligaments, Articular , Lumbar Vertebrae , Sacroiliac Joint , Humans , Biomechanical Phenomena/physiology , Sacroiliac Joint/physiopathology , Ligaments, Articular/physiopathology , Ligaments, Articular/physiology , Range of Motion, Articular/physiology , Joint Instability/physiopathology , Elastic Modulus , Stress, Mechanical
3.
Sheng Wu Yi Xue Gong Cheng Xue Za Zhi ; 41(1): 144-151, 2024 Feb 25.
Article in Chinese | MEDLINE | ID: mdl-38403615

ABSTRACT

The material properties and volume proportion of the fibers as well as the cross-sectional area proportion of nucleus pulposus vary greatly in different studies. The effect of these factors on the mechanical behavior of intervertebral discs (IVDs) are uncertain. The IVDs finite element models with different parameters were created to investigate the pressure, height, rotation, stress, and strain of the IVDs under loads: pure compression, rotation after compression or axial moment after compression. The results showed that the material properties of fibers had great impact on the mechanical behavior of IVDs, especially on the rotation angle. When the fiber volume ratio was small, its changes had a significant impact on the rotation angle of the IVDs. The area proportions of nucleus pulposus had relatively little effect on the mechanical behavior of IVDs. The IVDs rotation should be observed when validating the model. By adjusting the elastic modulus or volume ratio of fibers within a reasonable range, a model that could simulate the mechanical behavior of normal IVDs could be obtained. It was reasonable to make the area proportion of nucleus pulposus within 25%-50% for the IVDs finite element model. This study provides guidance and reference for finite element modeling of the IVDs and the investigation of the IVDs degeneration mechanism.


Subject(s)
Intervertebral Disc Degeneration , Intervertebral Disc , Nucleus Pulposus , Humans , Elastic Modulus , Pressure , Stress, Mechanical , Biomechanical Phenomena
4.
Article in English | MEDLINE | ID: mdl-38235712

ABSTRACT

The study aimed to investigate the dynamic characteristics of the cervical spine and determine the effect of the material properties of the cervical spinal components on it. A finite element model of the head-cervical spine was developed based on CT scan data, and the first six orders of modes (e.g. flexion-extension, lateral bending, and vertical, etc.) were verified by experimental and simulation studies. The material sensitivity study was conducted by varying elasticity modulus of cervical hard tissues (cortical bone, cancellous bone, endplates, and posterior elements) and soft tissues (intervertebral disc and ligaments). The results showed that increasing the elastic modulus of ligaments by 4 times increased the natural frequency by 77%, while increasing that of cancellous bone by 4 times only increased the natural frequency by 6%. In the axial mode, the cervical spine had not only axial deformation but also anterior-posterior deformation, with the largest deformation located at the intervertebral disc C6-C7. Decreasing the elastic modulus of a component in soft tissues by 80% increased modal displacement by up to 62%. The material properties of the intervertebral discs and ligaments had opposite effects on the modal displacement and deformation of the cervical spine. Low cervical discs were more susceptible to injury in a vertical vibration environment. Cervical spine dynamics were more sensitive to soft tissue material properties than to hard tissue material properties. Disc degeneration could reduce the range of vibratory motion of the cervical spine, thereby reducing the ability of the cervical spine to cushion head impacts.

5.
Clin Biomech (Bristol, Avon) ; 111: 106164, 2024 01.
Article in English | MEDLINE | ID: mdl-38159326

ABSTRACT

BACKGROUND: Studies focusing on lumbar spine biomechanics are very limited, and the mechanism of the effect of vibration on lumbar spine biodynamics is unclear. To provide guidance and reference for lumbar spine biodynamics research and vibration safety assessment, this study aims to investigate the effects of different vibrations on lumbar spine biodynamics. METHODS: A validated finite element model of the lumbosacral spine was utilized. The model incorporated a 40 kg mass on the upper side and a 400 N follower preload. As a comparison, another model without a coupled mass was also employed. A sinusoidal acceleration with an amplitude of 1 m/s2 and a frequency of 5 Hz was applied to the upper and lower sides of the model respectively. FINDINGS: When the coupled mass point is not introduced: in the case of upper-side excitation, the lumbar spine shows a significantly larger response in the x-direction than in the z-direction, while in the case of lower-side excitation, the lumbar spine experiences rigid body displacement in the z-direction without any movement, deformation, rotation, or stress changes in the x-direction. When the coupled mass point is introduced: both upper and lower-side excitations result in significant differences in z-directional displacement, with relatively small differences in vertebral rotation angle, disc deformation, and stress. Under upper excitation, low-frequency oscillations occur in the x-direction. In both types of excitations, the anterior-posterior deformation of the L2-L3 and L4-L5 intervertebral discs is greater than the vertical deformation. The peak (maximum) disc stress exceeds the average stress and stress amplitude across the entire disc. Regardless of the excitation type, the stress distribution within the disc at the moment of peak displacement remains nearly identical, with the maximum stress consistently localized on the anterior side of the L4-L5 disc. INTERPRETATION: Accurately simulating lumbar spine biodynamics requires the inclusion of the upper body mass in the lumbosacral spine model. The physiological curvature of the lumbar spine could escalate the risk of lumbar spine vibration injuries. It is more instructive to apply local high stress in the disc as a lumbar spine vibration safety evaluation parameter.


Subject(s)
Intervertebral Disc , Spinal Diseases , Humans , Vibration , Finite Element Analysis , Lumbar Vertebrae/physiology , Intervertebral Disc/physiology , Biomechanical Phenomena
6.
Sci Rep ; 13(1): 17905, 2023 Oct 20.
Article in English | MEDLINE | ID: mdl-37863973

ABSTRACT

Ship noise analysis is a critical area of research in hydroacoustic remote sensing due to its practical implications in identifying ship direction, type, and even specific ship identities. However, the limited availability of data poses challenges in developing accurate ship noise classification models. Previous studies have mainly focused on small-sample learning approaches, resulting in complex network structures. Nonetheless, underwater robots often have limited computing power, making it essential to develop simpler recognition networks. In this paper, we address the issue of data scarcity by introducing positive incentive noise. We propose a CNN-based hydroacoustic signal recognition method that achieves comparable or superior performance to previous studies, using a simple network structure as a back-end decision system. We describe the feature extraction process using a dataset with added noise and compare the performance of various features. Additionally, we compare our proposed method with previous studies. Experimental results demonstrate that simple neural networks can achieve high performance and excellent generalizability without the need for complex network structures like adversarial learning models.

7.
Article in English | MEDLINE | ID: mdl-37668064

ABSTRACT

Due to ethical issues and simplification of traditional biomechanical models, experimental methods and traditional computer methods were difficult to quantify the effects of foot excitation and shin posture on vibration behavior of the entire spine inside a seated human body under vertical whole-body vibration. This study developed and verified different three-dimensional (3D) finite element (FE) models of seated human body with detailed anatomical structure under the biomechanical characteristics to predict vibration behavior of the entire spine inside a seated human body with different foot excitation (with and without vibration) and shin posture (vertical and tilt posture). Random response analysis was performed to study the transmissibility of the entire spine to seat under vertical white noise excitation between 0 and 20 Hz at 0.5 m/s2 r.m.s. The results showed that although the foot excitation could reduce the fore-aft transmissibility in the cervical spine (23% reduction), it could significantly increase that in the lumbar spine (52% increase), which resulted in complex alternating stresses at lumbar spine and made the lumbar spine more vulnerable to injury in long-term vibration environment. Moreover, the shin tilt posture made the maximum fore-aft transmissibility in the lumbar spine move to the upper lumbar spine. The study provided new insights into the influence of foot excitation and shin posture on the vibration behavior of the entire spine inside a seated human body. Foot excitation exposed the lumbar spine to complex alternating stresses and made it more vulnerable to injury in long-term whole body vibration.

8.
Proc Inst Mech Eng H ; 236(11): 1654-1661, 2022 Nov.
Article in English | MEDLINE | ID: mdl-36121052

ABSTRACT

The burr at the hole exit is one of the key factors affecting bone drilling performances. In order to reduce burr height at hole exit during cortical bone drilling, the four key parameters in twist drilling of bones are analyzed based on the response surface method (RSM). The prediction model of the burr height is obtained via the analysis of variance. The influence trend and size of each factor on the height of the burr are further analyzed based on the RSM. Experimental results show that smaller point angle and diameter of the twist drill, smaller feed speed, and higher rotational speed can effectively reduce the burr height at hole exit. Then, the geometric variables of the twist drill and process parameters are optimized. When the point angle of the twist drill 2Φ = 95°, the diameter D = 2.5 mm, the rotational speed n = 1500 rpm, and the feed speed vf = 10 mm/min, the height of the burr at hole exit reaches the smallest. At the same time, the burr at the exit of the hole with different diameters of twist drills is studied. It is found to be beneficial to select a twist drill with a smaller diameter for drilling when the requirements of drilling are fulfilled.


Subject(s)
Bone and Bones , Surgical Instruments , Cortical Bone
9.
Materials (Basel) ; 15(14)2022 Jul 14.
Article in English | MEDLINE | ID: mdl-35888357

ABSTRACT

In this study, laser-assisted machining experiments are carried out on silicon carbide (SiC) ceramic materials by a turning process, and laser power, cutting depth, rotational speed, and feed speed are selected as research factors. In order to improve the surface processing quality of laser-assisted turning of SiC ceramics and obtain the smallest surface roughness, the orthogonal method and response surface method are used to investigate the effect of various factors on surface roughness. The effect of various factors on surface roughness is evaluated by variance analysis, mean analysis, main effect diagram, 3D response surface, and corresponding contour diagram. The surface roughness prediction model is established based on the response surface method, and the prediction error is 4.1% with high accuracy. The experimental results show that laser power and cutting depth are the most significant factors affecting surface roughness, and rotational speed is a significant factor affecting surface roughness. Under the optimum process conditions, the smallest surface roughness Ra obtained by the response surface method is 0.294 µm, which is lower than 0.315 µm obtained by the orthogonal method, and the surface quality is higher. Therefore, the optimal process parameters of the response surface method can obtain the smallest surface roughness and higher surface quality in laser-assisted turning of SiC ceramics.

10.
Technol Health Care ; 30(2): 455-467, 2022.
Article in English | MEDLINE | ID: mdl-34275916

ABSTRACT

BACKGROUND: In order to alleviate muscle fatigue and improve ride comfort, many published studies aimed to improve the seat environment or optimize seating posture. However, the effect of lumbar support on the lumbar muscle of seated subjects under whole body vibration is still unclear. OBJECTIVE: This study aimed to investigate the effect of lumbar support magnitude of the seat on lumbar muscle fatigue relief under whole body vibration. METHODS: Twenty healthy volunteers without low back pain participated in the experiment. By measuring surface electromyographic signals of erector spinae muscles under vibration or non-vibration for 30 minutes, the effect of different lumbar support conditions on muscle fatigue was analyzed. The magnitude of lumbar support d is assigned as d1= 0 mm, d2= 20 mm and d3= 40 mm for no support, small support and large support, respectively. RESULTS: The results showed that lumbar muscle activation levels vary under different support conditions. For the small support case (d2= 20 mm), the muscle activation level under vibration and no-vibration was the minimum, 42.3% and 77.7% of that under no support (d1= 0 mm). For all support conditions, the muscle activation level under vibration is higher than that under no-vibration. CONCLUSIONS: The results indicate that the small support yields the minimum muscle contraction (low muscle contraction intensity) under vibration, which is more helpful for relieving lumbar muscle fatigue than no support or large support cases. Therefore, an appropriate lumbar support of seats is necessary for alleviating lumbar muscle fatigue.


Subject(s)
Muscle Fatigue , Vibration , Electromyography , Humans , Lumbosacral Region , Muscle Contraction/physiology , Posture/physiology , Vibration/therapeutic use
11.
Micromachines (Basel) ; 12(12)2021 Dec 06.
Article in English | MEDLINE | ID: mdl-34945366

ABSTRACT

Cardiovascular disease is the leading cause of death worldwide. Traditional autologous transplantation has become a severe issue due to insufficient donors. Artificial blood vessel is an effective method for the treatment of major vascular diseases, such as heart and peripheral blood vessel diseases. However, the traditional single-material printing technology has been unable to meet the users' demand for product functional complexity, which is not only reflected in the field of industrial manufacturing, but also in the field of functional vessel-like structure regeneration. In order to achieve the printing and forming of multi-layer vessel-like structures, this paper carries out theoretical and experimental research on the printing and forming of a multi-layer vessel-like structure based on multi-material 3D bioprinting technology. Firstly, theoretical analysis has been explored to research the relationship among the different parameters in the process of vessel forming, and further confirm the synchronous relationship among the extrusion rate of material, the tangential speed of the rotating rod, and the movement speed of the platform. Secondly, sodium alginate and gelatin have been used as the experimental materials to manufacture the vessel-like structure, and the corrected parameter of the theoretical analysis is further verified. Finally, the cell-loaded materials have been printed and analyzed, and cell viability is more than 90%, which provides support for the research of multi-layer vessel-like structure printing.

12.
Article in English | MEDLINE | ID: mdl-28264145

ABSTRACT

The aim of this study is to model the computational model of seated whole human body including skeleton, muscle, viscera, ligament, intervertebral disc, and skin to predict effect of the factors (sitting postures, muscle and skin, buttocks, viscera, arms, gravity, and boundary conditions) on the biodynamic characteristics of spine. Two finite element models of seated whole body and a large number of finite element models of different ligamentous motion segments were developed and validated. Static, modal, and transient dynamic analyses were performed. The predicted vertical resonant frequency of seated body model was in the range of vertical natural frequency of 4 to 7 Hz. Muscle, buttocks, viscera, and the boundary conditions of buttocks have influence on the vertical resonant frequency of spine. Muscle played a very important role in biodynamic response of spine. Compared with the vertical posture, the posture of lean forward or backward led to an increase in stress on anterior or lateral posterior of lumbar intervertebral discs. This indicated that keeping correct posture could reduce the injury of vibration on lumbar intervertebral disc under whole-body vibration. The driving posture not only reduced the load of spine but also increased the resonant frequency of spine.


Subject(s)
Models, Biological , Posture , Spine/physiology , Finite Element Analysis , Humans , Muscle, Skeletal/physiology , Vibration , Viscera
SELECTION OF CITATIONS
SEARCH DETAIL
...