Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
J Chromatogr Sci ; 56(8): 724-730, 2018 Sep 01.
Article in English | MEDLINE | ID: mdl-29762651

ABSTRACT

A rapid and sensitive high-performance liquid chromatography-mass spectrometry method was developed and validated to determine 4-fluoroaniline concentration in ezetimibe. Chromatographic separation was achieved on a Phenomenex Gemini-NX C18 column (150 × 4.6 mm, 3 µm) maintained at 30°C. The liquid chromatography system was operated in gradient mode with an injection volume of 20 µL at a flow rate of 1 mL/min. Mobile phase A was water and mobile phase B consisted of acetonitrile with 0.05% acetic acid. The detection was performed using a single quadrupole mass spectrometer in single ion monitoring mode by using positive ionization. An m/z value of 112 was selected for monitoring 4-fluoroaniline. The method showed good linearity over the concentration range of 0.94-30.26 ng/mL. The limit of quantification and limit of detection were 0.19 and 0.94 ng/mL, respectively. The precision relative standard deviations were less than 8.7% (n = 12), and the accuracy values were within 92-99%. A standard solution of 4-fluoroaniline was stable for at least 24 h at 25°C. Small changes in the organic phase acidity of the mobile phase, flow rate, column temperature, and the instrument parameters had no significant effect on the results for 4-fluoroaniline.


Subject(s)
Aniline Compounds/analysis , Anticholesteremic Agents/chemistry , Chromatography, High Pressure Liquid/methods , Drug Contamination , Ezetimibe/chemistry , Spectrometry, Mass, Electrospray Ionization/methods , Chromatography, High Pressure Liquid/economics , Limit of Detection , Reproducibility of Results , Spectrometry, Mass, Electrospray Ionization/economics
2.
Anal Sci ; 33(3): 293-298, 2017.
Article in English | MEDLINE | ID: mdl-28302969

ABSTRACT

A sensitive non-derivatization method for the determination of the highly polar compound 3-aminopiperidine was developed using a mixed-mode column combined with a charged aerosol detector (CAD). Chromatographic conditions, including the type of detector, separation mode, and mobile phase composition, were optimized to achieve high sensitivity towards and sufficient retention of 3-aminopiperidine. Compared to the precolumn derivatization UV method, the current method showed higher recovery and greater simplicify. High sensitivity (LOQ <2.73 µg mL-1) and good precision (RSD of peak area <2%) were also observed in the current method. Furthermore, the parameters such as buffer solution and column bleed that affected the sensitivity of the CAD were investigated. Finally, the current method was applied for the determination of 3-aminopiperidine in linagliptin samples. This is a new non-derivative for the determination of 3-aminopiperidine, and constitutes a novel application of the CAD for the quantitative analysis of highly polar basic compounds.

3.
Anal Sci ; 32(12): 1333-1338, 2016.
Article in English | MEDLINE | ID: mdl-27941264

ABSTRACT

A rapid and sensitive high-performance liquid chromatography-mass spectrometry method was established to determine the trace residues of piperazine in vortioxetine hydrobromide. The presence of piperazine was determined by precolumn derivatization with dansyl chloride. Chromatographic separation was performed on a Waters SunFire C8 column (150 × 4.6 mm, 3.5 µm) in gradient elution mode, using formic acid and acetonitrile as mobile phase. Detection was performed in a single quadrupole mass spectrometer in single ion monitoring mode using positive ionization. An m/z value of 553 was selected for monitoring disubstituted piperazine by DNS-Cl. Linearity, accuracy, and precision were found to be acceptable over the piperazine concentration range of 0.3525 - 2.35 ng mL-1. The limit of detection and limit of quantification of piperazine were 0.1175 and 0.3525 ng mL-1, respectively, which complied with the requirements of qualitative and quantitative analyses. The method was deemed sensitive and efficient.

SELECTION OF CITATIONS
SEARCH DETAIL
...