Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 13 de 13
Filter
Add more filters










Publication year range
1.
Insights Imaging ; 15(1): 109, 2024 Apr 29.
Article in English | MEDLINE | ID: mdl-38679659

ABSTRACT

OBJECTIVE: To determine whether quantitative parameters of detector-derived dual-layer spectral computed tomography (DLCT) can reliably identify epidermal growth factor receptor (EGFR) mutation status in patients with non-small cell lung cancer (NSCLC). METHODS: Patients with NSCLC who underwent arterial phase (AP) and venous phase (VP) DLCT between December 2021 and November 2022 were subdivided into the mutated and wild-type EGFR groups following EGFR mutation testing. Their baseline clinical data, conventional CT images, and spectral images were obtained. Iodine concentration (IC), iodine no water (INW), effective atomic number (Zeff), virtual monoenergetic images, the slope of the spectral attenuation curve (λHU), enhancement degree (ED), arterial enhancement fraction (AEF), and normalized AEF (NAEF) were measured for each lesion. RESULTS: Ninety-two patients (median age, 61 years, interquartile range [51, 67]; 33 men) were evaluated. The univariate analysis indicated that IC, normalized IC (NIC), INW and ED for the AP and VP, as well as Zeff and λHU for the VP were significantly associated with EGFR mutation status (all p < 0.05). INW(VP) showed the best diagnostic performance (AUC, 0.892 [95% confidence interval {CI}: 0.823, 0.960]). However, neither AEF (p = 0.156) nor NAEF (p = 0.567) showed significant differences between the two groups. The multivariate analysis showed that INW(AP) and NIC(VP) were significant predictors of EGFR mutation status, with the latter showing better performance (p = 0.029; AUC, 0.897 [95% CI: 0.816, 0.951] vs. 0.774 [95% CI: 0.675, 0.855]). CONCLUSION: Quantitative parameters of DLCT can help predict EGFR mutation status in patients with NSCLC. CRITICAL RELEVANCE STATEMENT: Quantitative parameters of DLCT, especially NIC(VP), can help predict EGFR mutation status in patients with NSCLC, facilitating appropriate and individualized treatment for them. KEY POINTS: Determining EGFR mutation status in patients with NSCLC before starting therapy is essential. Quantitative parameters of DLCT can predict EGFR mutation status in NSCLC patients. NIC in venous phase is an important parameter to guide individualized treatment selection for NSCLC patients.

2.
Quant Imaging Med Surg ; 14(1): 698-710, 2024 Jan 03.
Article in English | MEDLINE | ID: mdl-38223075

ABSTRACT

Background: Virtual monochromatic image (VMI) combined with orthopedic metal artifact reduction algorithms (VMI + O-MAR) can effectively reduce artifacts caused by metal implants of different types. Nevertheless, so far, no study has systematically evaluated the efficacy of VMI + O-MAR in reducing various types of metal artifacts induced by 125I seeds. The aim of this study was to assess the effectiveness of combining spectral computed tomography (CT) images with O-MAR in reducing metal artifacts and improving the image quality affected by artifacts in patients after 125I radioactive seeds implantation (RSI). Methods: A total of 45 patients who underwent dual-layer detector spectral CT (DLCT; IQon, Philips Healthcare) scanning of mediastinal and hepatic tumors after 125I RSI were retrospectively included. Spectral data were reconstructed into conventional image (CI), VMI, CI combined with O-MAR (CI + O-MAR), and VMI + O-MAR to evaluate the de-artifact effect and image quality improvement. Objective indicators included signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and artifact index (AI) of lesions affected by artifacts. Subjective indicators included assessment of overcorrected artifacts and new artifacts, different morphology of artifacts, and overall image quality. Results: In artifact-affected lesion areas, SNR and CNR in the CI/VMI + O-MAR groups were better than those in CI groups (all P values <0.05). The AI showed a downward trend as VMI keV increased (all P values <0.001). The AI values of the CI/VMI (50-150 keV) group were all higher than the groups of CI/VMI + O-MAR (50-150 keV) (P<0.001). Overcorrection artifacts and new artifacts were concentrated in the VMI50/70 keV groups. In the evaluation of artifact morphology, as the VMI keV increased, the number of near-field banding artifacts in hyperdense artifacts gradually decreased, whereas the number of minimal or no artifacts increased, and the total number of hyperdense artifacts were decreased. The diagnostic and image quality scores of hyperdense artifacts were higher than those of hypodense artifacts as VMI keV increased. Conclusions: High VMI level combined with O-MAR substantially improve objective and subjective image quality, lesion display ability, and diagnostic confidence of CT follow-up after 125I RSI, especially at the VMI + O-MAR 150 keV level.

3.
Quant Imaging Med Surg ; 14(1): 618-632, 2024 Jan 03.
Article in English | MEDLINE | ID: mdl-38223086

ABSTRACT

Background: Very early distant metastasis (VEDM) for patients with colorectal cancer (CRC) following surgery suggests failure of local treatment strategy and few biomarkers are available for its effective risk stratification. This study aimed to explore the potential of quantitative dual-energy computed tomography (DECT) spectral parameters and build models to predict VEDM. Methods: Consecutive patients suspected of having CRC and with a clinical indication for enhanced CT from April 2021 to July 2022 at a single institution were prospectively enrolled to undertake spectral CT scanning. The spectral features were extracted by two reviewers and intraclass correlation coefficient (ICC) was used for interobserver agreement evaluation. A total of 16 spectral parameters, including unenhanced effective atomic number, triphasic iodine concentrations (ICs)/normalized ICs (NICs)-A/V/E/1/NIC-A/V/E/spectral curve slopes (λ-A/V/E), two arterial enhancement fractions (AEFs), and venous enhancement fraction (VEF), were determined for analysis. Patients with and without VEDM after surgery were matched using propensity score matching (PSM). The diagnostic performance was assessed using the area under the curve (AUC). Models of multiple modalities were generated. Results: In total, 222 patients were included (141 males, age range, 32-83 years) and 13 patients developed VEDM. Interobserver agreement ranged from good to excellent (ICC, 0.773-0.964). A total of three spectral parameters (VEF, λ-V, and 1/NIC-V) exhibited significant discriminatory ability (P<0.05) in predicting VEDM, with AUCs of 0.822 [95% confidence interval (CI): 0.667-0.926], 0.738 (95% CI: 0.573-0.866), and 0.713 (95% CI: 0.546-0.846) and optimal cutoff points of 67.16%, 2.46, and 2.44, respectively. The performance of these spectral parameters was validated in the entire cohort; the combined spectral model showed comparable efficiency to the combined clinical model [AUC, 0.771 (95% CI: 0.622-0.919) vs. 0.779 (95% CI: 0.663-0.894), P>0.05]; the clinical-spectral model achieved further improved AUC of 0.887 (95% CI: 0.812-0.962), which was significantly higher than the combined clinical model (P=0.015), yet not superior to the combined spectral model (P=0.078). Conclusions: Novel spectral parameters showed potential in predicting VEDM in CRC following surgery in this preliminary study, which were closely related with spectral perfusion in the venous phase. However, further studies with larger samples are warranted.

4.
Quant Imaging Med Surg ; 13(10): 6456-6467, 2023 Oct 01.
Article in English | MEDLINE | ID: mdl-37869326

ABSTRACT

Background: Computed tomography angiography (CTA) is the recommended diagnostic and follow-up imaging modality for acute aortic dissection (AD). However, the high-contrast medium burden associated with repeated CT aortography follow-ups remains a significant concern. This prospective study aimed to assess whether an ultra-low contrast dose (75% cutoff) aortic CTA protocol on dual-layer spectral CT could achieve comparable image quality with the full dose protocol. We also investigated the image quality of the virtual noncontrast (VNC) images derived from the ultra-low dose protocol. Methods: This study included 37 consecutive patients who were referred to aortic CTA from May 2022 to August 2022. The enrolled patients underwent full-dose contrast CTA and ultra-low dose (reduced to 25% of conventional) contrast CTA on dual-layer spectral CT in 1 day. Virtual monochromatic images (VMIs) were reconstructed with 40 and 70 keV. The VNC images were reconstructed for both protocols. Objective image quality evaluation, recorded as signal-to-noise ratios (SNRs) and contrast-to-noise ratios (CNRs), was compared between the groups using 1-way analysis of variance and post hoc analysis with Bonferroni correction. Subjective image quality was also compared between the groups. Finally, VNC images derived from the low-dose (VNClow) and full-dose (VNCfull) protocols were compared to the true noncontrast (TNC) images. Results: Neither CNR nor SNR was lower for the 40-keV images reconstructed from the ultra-low dose group compared to the conventional images. Both were significantly higher than those of the 70-keV images. Regarding subjective image quality, vessel enhancement was not significantly different between the 40-keV VMI and full-dose images [ascending aorta (AAO): 4.37±0.46 vs. 4.57±0.48, P=0.096; brachiocephalic arteries: 4.34±0.45 vs. 4.51±0.49, P=0.152; abdominal aortic side branch: 4.42±0.48 vs. 4.51±0.49, P=0.480]. The VNClow images were similar to the TNC images but significantly different from the VNCfull images (P<0.001). Conclusions: Ultra-low contrast aortic CTA with a 75%-reduced iodine dose using dual-layer spectral CT and the derived VNC achieved image quality comparable to that of conventional CTA and TNC images.

5.
Heliyon ; 9(10): e20758, 2023 Oct.
Article in English | MEDLINE | ID: mdl-37860545

ABSTRACT

Objective: To investigate the accuracy of calcicum supression (CaSupp) technique derived from double-layer detector spectral computed tomography (DSCT) in the diagnosis of traumatic bone marrow edema in the knee. Methods: Twenty-three patients with trauma in the knee who underwent DSCT and Magnetic Resonance Imaging (MRI) in the Third Hospital of Hebei Medical University from October 2021 to March 2022 were retrospectively collected. To make the evaluation more detailed and accurate, each knee was divided into 10 partitions. Bone marrow edema in each partition of the knee was evaluated by two physicians (physician A and B) using CaSupp images combined with conventional CT-CaSupp fusion false-color images. MRI results were used as the gold standard and the accuracy of the CaSupp technique was analyzed in the diagnosis of traumatic bone marrow edema in the knee. The CaSuppCT values of the normal bone marrow area and the bone marrow edema area were delineated, and receiver operating curve (ROC curve) was drawn to find the optimal cut-off value of CaSuppCT as the quantitative parameter for the diagnosis of bone marrow edema. Results: The diagnostic sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of physician A were 83.1 %, 98.1 %, 95.5 % and 92.1 %, respectively; those of physician B were 93.5 %, 97.4 %, 94.7 % and 96.8 %, respectively. The CaSuppCT values in the bone marrow edema areas were higher than those in the normal areas, and the difference was statistically significant. The area under the receiver operating characteristic curve (AUC) of the CaSuppCT values was 0.979, and the cut-off value was 7.05Hu*. The corresponding diagnostic sensitivity was 87.0 %, and specificity was 100.0 %. Conclusion: The CaSupp technique derived from DSCT has high sensitivity and specificity in the detection of traumatic bone marrow edema in the knee, and can provide more imaging information for clinical practice.

6.
Diagnostics (Basel) ; 13(15)2023 Aug 01.
Article in English | MEDLINE | ID: mdl-37568923

ABSTRACT

BACKGROUND: This study aimed to investigate the natural growth history of peripheral small-cell lung cancer (SCLC) using CT imaging. METHODS: A retrospective study was conducted on 27 patients with peripheral SCLC who underwent at least two CT scans. Two methods were used: Method 1 involved direct measurement of nodule dimensions using a calliper, while Method 2 involved tumour lesion segmentation and voxel volume calculation using the "py-radiomics" package in Python. Agreement between the two methods was assessed using the intraclass correlation coefficient (ICC). Volume doubling time (VDT) and growth rate (GR) were used as evaluation indices for SCLC growth, and growth distribution based on GR and volume measurements were depicted. We collected potential factors related to imaging VDT and performed a differential analysis. Patients were classified into slow-growing and fast-growing groups based on a VDT cut-off point of 60 days, and univariate analysis was used to identify factors influencing VDT. RESULTS: Median VDT calculated by the two methods were 61 days and 71 days, respectively, with strong agreement. All patients had continuously growing tumours, and none had tumours that decreased in size or remained unchanged. Eight patients showed possible growth patterns, with six possibly exhibiting exponential growth and two possibly showing Gompertzian growth. Tumours deeper in the lung grew faster than those adjacent to the pleura. CONCLUSIONS: Peripheral SCLC tumours grow rapidly and continuously without periods of nongrowth or regression. Tumours located deeper in the lung tend to grow faster, but further research is needed to confirm this finding.

7.
Quant Imaging Med Surg ; 13(5): 2975-2988, 2023 May 01.
Article in English | MEDLINE | ID: mdl-37179933

ABSTRACT

Background: Coronary atherosclerosis is a chronic inflammatory condition. Pericoronary adipose tissue (PCAT) attenuation is closely related to coronary inflammation. This study aimed to investigate the relationship between PCAT attenuation parameters and coronary atherosclerotic heart disease (CAD) using dual-layer spectral detector computed tomography (SDCT). Methods: This cross-sectional study included eligible patients who underwent coronary computed tomography angiography using SDCT at the First Affiliated Hospital of Harbin Medical University between April 2021 and September 2021. Patients were classified as CAD (with coronary artery atherosclerotic plaque) or non-CAD (without coronary artery atherosclerotic plaque). Propensity score matching was used to match the two groups. The fat attenuation index (FAI) was used to quantify PCAT attenuation. The FAI was measured on conventional images (120 kVp) and virtual monoenergetic images (VMI) by semiautomatic software. The slope of the spectral attenuation curve (λ) was calculated. Regression models were established to evaluate the predictive value of PCAT attenuation parameters for CAD. Results: A total of 45 patients with CAD and 45 patients without CAD were enrolled. The PCAT attenuation parameters in the CAD group were significantly higher than those in the non-CAD group (all P values <0.05). The PCAT attenuation parameters of vessels with or without plaques in the CAD group were higher than those of vessels without plaques in the non-CAD group (all P values <0.05). In the CAD group, the PCAT attenuation parameters of vessels with plaques were slightly higher than those of vessels without plaques (all P values >0.05). In receiver operating characteristic curve analysis, the FAIVMI model achieved an area under the curve (AUC) of 0.8123 for discriminating between patients with and without CAD, which was higher than those of the FAI120 kVp model (AUC =0.7444) and the λ model (AUC =0.7230). However, the combined model of FAIVMI, FAI120 kVp, and λ obtained the best performance (AUC =0.8296) of all the models. Conclusions: PCAT attenuation parameters obtained using dual-layer SDCT can aid in distinguishing patients with and without CAD. By detecting increases in PCAT attenuation parameters, it might be possible to predict the formation of atherosclerotic plaques before they appear.

8.
ACS Omega ; 8(10): 9265-9274, 2023 Mar 14.
Article in English | MEDLINE | ID: mdl-36936331

ABSTRACT

Nickel borides are promising multifunctional materials for high hardness and excellent properties in catalysis and magnetism. However, it is still a blank of intrinsic properties in Ni-B compounds, because crystallization of the single phases of Ni-B compounds with micro-size is a challenge. In this work, single phases of Ni2B (I4/mcm), α-Ni4B3 (Pnma), ß-Ni4B3 (C2/c), and NiB (Cmcm) are synthesized by high pressure and high temperature (HPHT). The results indicate that synthesizing α-Ni4B3 and ß-Ni4B3 requires more energy than Ni2B and NiB. The growth process of Ni-B compounds is that Ni covers B to form Ni-B compounds under HPHT, which also makes the slight excess of B necessary. So, generating homogeneous distribution of starting materials and increasing the interdiffusion between Ni and B are two keys to synthesize well crystallized and purer samples by HPHT. This work uncovers the growth process of Ni-B compounds, which is significant to guide the synthesis of highly crystalline transition metal borides (TMBs) in the future.

9.
Rev Sci Instrum ; 93(10): 103901, 2022 Oct 01.
Article in English | MEDLINE | ID: mdl-36319382

ABSTRACT

Regulating electron structure and electron-phonon coupling by means of pressure and temperature is an effective way to optimize thermoelectric properties. However, in situ testing of thermoelectric transport performance under pressure and temperature is hindered by technical constraints that obscure the intrinsic effects of pressure and temperature on thermoelectric properties. In the present study, a new reliable assembly was developed for testing the in situ thermoelectric transport performance of materials at high pressure and high temperature (HPHT). This reduces the influence of thermal effects on the test results and improves the success rate of in situ experiments at HPHT. The Seebeck coefficient and electrical resistivity of α-Cu2Se were measured under HPHT, and the former was found to increase with increasing pressure and temperature; for the latter, although an increase in the pressure acted to lower the electrical resistivity, an increase in the temperature acted to increase it. On increasing pressure from 0.8 to 3 GPa at 333 K, the optimal power factor of α-Cu2Se was increased by ∼76% from 2.36 × 10-4-4.15 × 10-4 W m-1 K-2, and the higher pressure meant that α-Cu2Se had its maximum power factor at lower temperature. The present work is particularly important for understanding the thermoelectric mechanism under HPHT.

10.
ACS Appl Mater Interfaces ; 13(48): 58162-58169, 2021 Dec 08.
Article in English | MEDLINE | ID: mdl-34809421

ABSTRACT

Exploring the hydrophobicity of robust conductors is significant for electronic devices to simultaneously be used in a wet environment and extreme conditions. However, a combination of conductivity, strong mechanical properties, and hydrophobicity in one material is hindered by the inherent features of the materials. A new kind of robust hydrophobic conductor is designed in transition-metal diborides (TMdBs: TiB2, ZrB2, and HfB2) to break through this challenge. The results calculated by density functional theory indicate that high hardness comes from high shear and bulk modulus, which is consistent with experimental results (TiB2, 25.0 GPa; ZrB2, 17.5 GPa; HfB2, 21.5 GPa). The theoretical calculated results reveal that edge sides have a lower surface energy than basal plane (001) in TMdBs. Hence, the edge sides are exposed with a needle-like morphology in TMdBs. Moreover, needle-like surfaces exhibiting hydrophobicity have water contact angles of 132.0° (TiB2), 116.8° (ZrB2), and 114.0° (HfB2). The hydrophobicity arises from a lower surface free energy of edge sides in TMdBs and a rough surface that reduces the contact area of water and a solid. This work develops a new kind of robust functional material in TMdBs.

11.
Materials (Basel) ; 12(11)2019 May 31.
Article in English | MEDLINE | ID: mdl-31159328

ABSTRACT

Amorphous carbon (a-C) films are attracting considerable attention to due their large optical band gap (Eopt) range of 1-4 eV. But the hopping conducting mechanism of boron doping a-C (a-C:B) is still mysterious. To exploring the intrinsic reasons behind the semiconductor properties of a-C:B, in this work, the boron doping a-C (a-C:B) nano-film was prepared, and the growth rate and Eopt changing were analyzed by controlling the different experimental conditions of magnetron sputtering. A rapid deposition rate of 10.55 nm/min was obtained. The Eopt is reduced from 3.19 eV to 2.78 eV by improving the substrate temperature and sputtering power. The proportion of sp2/sp3 increasing was uncovered with narrowing the Eopt. The shrinking Eopt can be attributed to the fact that boron atoms act as a fluxing agent to promote carbon atoms to form sp2 hybridization at low energy. Furthermore, boron atoms can impede the formation of σ bonds in carbon atom sp3 hybridization by forming B-C bonds with high energy, and induce the sp3 hybridization transfer to sp2 hybridization. This work is significant to further study of amorphous semiconductor films.

12.
Inorg Chem ; 56(7): 3970-3975, 2017 Apr 03.
Article in English | MEDLINE | ID: mdl-28328215

ABSTRACT

In this work, high-quality bulk WC-structured WN (δ-WN) was synthesized via an untraditional method and the structure was accurately determined by X-ray diffraction and Rietveld refinement. In the process of synthesizing δ-WN, W2N3 and melamine were used as tungsten source and nitrogen source, respectively. The result of successfully synthesized high-quality δ-WN indicates that our method is an effective route for synthesizing high-quality bulk δ-WN and melamine is a pure nitrogen source for introducing the nitrogen to the metal precursor. The mechanical properties, bulk modulus, and Vickers hardness (HV) were first investigated by in situ high-pressure X-ray diffraction and Vickers microhardness tests, respectively. It is worth noting that the bulk modulus of δ-WN is 373 ± 8.3 GPa, which is comparable to that of c-BN. The Vickers hardness is 13.8 GPa under an applied load of 4.9 N. It is worth noting that W-W metallic bond and W-N ionic bond are mainly chemical bond in δ-WN based on the analysis of electron localization function (ELF), density of states (DOS), and Mulliken population. This result can well clarify that δ-WN is only a hard material for the lack of strong W-N covalent bonds to form 3D network structure. Our results are helpful to understand the hardness mechanism and design superhard materials in transition-metal nitrides.

13.
Phys Chem Chem Phys ; 19(13): 8919-8924, 2017 Mar 29.
Article in English | MEDLINE | ID: mdl-28295104

ABSTRACT

In this work, the structure of WB2 synthesized at high pressure and high temperature (HPHT) was accurately determined by X-ray diffraction and Rietveld refinement. Its asymptotic Vickers hardness (Hv) value is 25.5 GPa which is much lower than the previous theoretical results (36-40 GPa). It is worth noting that the chemical bonds between the W layers and two different kinds of B layers show obvious polarization character based on the results obtained from X-ray photoelectron spectroscopy (XPS) and electron localization functions (ELFs), density of states (DOS), topological analysis of the static electron density and Mulliken population. This result can well clarify that WB2 is only a hard but not superhard material. Thus, a 3D network structure can not be formed between the W layers and the B layers which is previously predicted by theoretical calculations. Our results are helpful to understand the hardness mechanism and design superhard materials in TMBs.

SELECTION OF CITATIONS
SEARCH DETAIL
...