Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 75
Filter
1.
iScience ; 27(2): 108310, 2024 Feb 16.
Article in English | MEDLINE | ID: mdl-38303697

ABSTRACT

Local field potentials (LFPs) in the primate motor cortex have been shown to reflect information related to volitional movements. However, LFPs are composite signals that receive contributions from multiple neural sources, producing a complex mix of component signals. Using a blind source separation approach, we examined the components of neural activity recorded using multielectrode arrays in motor areas of macaque monkeys during a grasping and lifting task. We found a set of independent components in the low-frequency LFP with high temporal and spatial consistency associated with each task stage. We observed that ICs often arise from electrodes distributed across multiple cortical areas and provide complementary information to external behavioral markers, specifically in task stage detection and trial alignment. Taken together, our results show that it is possible to separate useful independent components of the LFP associated with specific task-related events, potentially representing internal markers of transition between cortical network states.

2.
Neurology ; 100(11): e1177-e1192, 2023 03 14.
Article in English | MEDLINE | ID: mdl-36639237

ABSTRACT

BACKGROUND AND OBJECTIVES: Brain-computer interfaces (BCIs) are being developed to restore mobility, communication, and functional independence to people with paralysis. Though supported by decades of preclinical data, the safety of chronically implanted microelectrode array BCIs in humans is unknown. We report safety results from the prospective, open-label, nonrandomized BrainGate feasibility study (NCT00912041), the largest and longest-running clinical trial of an implanted BCI. METHODS: Adults aged 18-75 years with quadriparesis from spinal cord injury, brainstem stroke, or motor neuron disease were enrolled through 7 clinical sites in the United States. Participants underwent surgical implantation of 1 or 2 microelectrode arrays in the motor cortex of the dominant cerebral hemisphere. The primary safety outcome was device-related serious adverse events (SAEs) requiring device explantation or resulting in death or permanently increased disability during the 1-year postimplant evaluation period. The secondary outcomes included the type and frequency of other adverse events and the feasibility of the BrainGate system for controlling a computer or other assistive technologies. RESULTS: From 2004 to 2021, 14 adults enrolled in the BrainGate trial had devices surgically implanted. The average duration of device implantation was 872 days, yielding 12,203 days of safety experience. There were 68 device-related adverse events, including 6 device-related SAEs. The most common device-related adverse event was skin irritation around the percutaneous pedestal. There were no safety events that required device explantation, no unanticipated adverse device events, no intracranial infections, and no participant deaths or adverse events resulting in permanently increased disability related to the investigational device. DISCUSSION: The BrainGate Neural Interface system has a safety record comparable with other chronically implanted medical devices. Given rapid recent advances in this technology and continued performance gains, these data suggest a favorable risk/benefit ratio in appropriately selected individuals to support ongoing research and development. TRIAL REGISTRATION INFORMATION: ClinicalTrials.gov Identifier: NCT00912041. CLASSIFICATION OF EVIDENCE: This study provides Class IV evidence that the neurosurgically placed BrainGate Neural Interface system is associated with a low rate of SAEs defined as those requiring device explantation, resulting in death, or resulting in permanently increased disability during the 1-year postimplant period.


Subject(s)
Brain-Computer Interfaces , Spinal Cord Injuries , Adult , Humans , Feasibility Studies , Prospective Studies , Quadriplegia , Spinal Cord Injuries/surgery
3.
Nat Commun ; 13(1): 1236, 2022 03 22.
Article in English | MEDLINE | ID: mdl-35318316

ABSTRACT

Patients with amyotrophic lateral sclerosis (ALS) can lose all muscle-based routes of communication as motor neuron degeneration progresses, and ultimately, they may be left without any means of communication. While others have evaluated communication in people with remaining muscle control, to the best of our knowledge, it is not known whether neural-based communication remains possible in a completely locked-in state. Here, we implanted two 64 microelectrode arrays in the supplementary and primary motor cortex of a patient in a completely locked-in state with ALS. The patient modulated neural firing rates based on auditory feedback and he used this strategy to select letters one at a time to form words and phrases to communicate his needs and experiences. This case study provides evidence that brain-based volitional communication is possible even in a completely locked-in state.


Subject(s)
Amyotrophic Lateral Sclerosis , Brain-Computer Interfaces , Neurofeedback , Amyotrophic Lateral Sclerosis/therapy , Brain/physiology , Electroencephalography , Humans , Language , Male
4.
PLoS Biol ; 18(9): e3000833, 2020 09.
Article in English | MEDLINE | ID: mdl-32898188

ABSTRACT

The phonological deficit in dyslexia is associated with altered low-gamma oscillatory function in left auditory cortex, but a causal relationship between oscillatory function and phonemic processing has never been established. After confirming a deficit at 30 Hz with electroencephalography (EEG), we applied 20 minutes of transcranial alternating current stimulation (tACS) to transiently restore this activity in adults with dyslexia. The intervention significantly improved phonological processing and reading accuracy as measured immediately after tACS. The effect occurred selectively for a 30-Hz stimulation in the dyslexia group. Importantly, we observed that the focal intervention over the left auditory cortex also decreased 30-Hz activity in the right superior temporal cortex, resulting in reinstating a left dominance for the oscillatory response. These findings establish a causal role of neural oscillations in phonological processing and offer solid neurophysiological grounds for a potential correction of low-gamma anomalies and for alleviating the phonological deficit in dyslexia.


Subject(s)
Dyslexia/therapy , Reading , Speech Perception , Adolescent , Adult , Auditory Cortex/physiopathology , Auditory Cortex/radiation effects , Dyslexia/physiopathology , Electroencephalography , Evoked Potentials, Auditory/physiology , Evoked Potentials, Auditory/radiation effects , Female , Humans , Male , Middle Aged , Phonetics , Speech Perception/physiology , Speech Perception/radiation effects , Transcranial Direct Current Stimulation/methods , Verbal Behavior/physiology , Verbal Behavior/radiation effects , Young Adult
5.
J Neurophysiol ; 121(4): 1428-1450, 2019 04 01.
Article in English | MEDLINE | ID: mdl-30785814

ABSTRACT

Intracortical brain-computer interfaces (BCIs) can enable individuals to control effectors, such as a computer cursor, by directly decoding the user's movement intentions from action potentials and local field potentials (LFPs) recorded within the motor cortex. However, the accuracy and complexity of effector control achieved with such "biomimetic" BCIs will depend on the degree to which the intended movements used to elicit control modulate the neural activity. In particular, channels that do not record distinguishable action potentials and only record LFP modulations may be of limited use for BCI control. In contrast, a biofeedback approach may surpass these limitations by letting the participants generate new control signals and learn strategies that improve the volitional control of signals used for effector control. Here, we show that, by using a biofeedback paradigm, three individuals with tetraplegia achieved volitional control of gamma LFPs (40-400 Hz) recorded by a single microelectrode implanted in the precentral gyrus. Control was improved over a pair of consecutive sessions up to 3 days apart. In all but one session, the channel used to achieve control lacked distinguishable action potentials. Our results indicate that biofeedback LFP-based BCIs may potentially contribute to the neural modulation necessary to obtain reliable and useful control of effectors. NEW & NOTEWORTHY Our study demonstrates that people with tetraplegia can volitionally control individual high-gamma local-field potential (LFP) channels recorded from the motor cortex, and that this control can be improved using biofeedback. Motor cortical LFP signals are thought to be both informative and stable intracortical signals and, thus, of importance for future brain-computer interfaces.


Subject(s)
Brain-Computer Interfaces , Gamma Rhythm , Motor Cortex/physiopathology , Quadriplegia/physiopathology , Adult , Electrodes, Implanted/adverse effects , Electrodes, Implanted/standards , Feedback, Physiological , Humans , Movement , Quadriplegia/rehabilitation
6.
Front Hum Neurosci ; 12: 450, 2018.
Article in English | MEDLINE | ID: mdl-30524258

ABSTRACT

Planning and performing volitional movement engages widespread networks in the human brain, with motor cortex considered critical to the performance of skilled limb actions. Motor cortex is also engaged when actions are observed or imagined, but the manner in which ensembles of neurons represent these volitional states (VoSs) is unknown. Here we provide direct demonstration that observing, imagining or attempting action activates shared neural ensembles in human motor cortex. Two individuals with tetraplegia (due to brainstem stroke or amyotrophic lateral sclerosis, ALS) were verbally instructed to watch, imagine, or attempt reaching actions displayed on a computer screen. Neural activity in the precentral gyrus incorporated information about both cognitive state and movement kinematics; the three conditions presented overlapping but unique, statistically distinct activity patterns. These findings demonstrate that individual neurons in human motor cortex reflect information related to sensory inputs and VoS in addition to movement features, and are a key part of a broader network linking perception and cognition to action.

7.
J Neurophysiol ; 120(1): 343-360, 2018 07 01.
Article in English | MEDLINE | ID: mdl-29694279

ABSTRACT

Restoring communication for people with locked-in syndrome remains a challenging clinical problem without a reliable solution. Recent studies have shown that people with paralysis can use brain-computer interfaces (BCIs) based on intracortical spiking activity to efficiently type messages. However, due to neuronal signal instability, most intracortical BCIs have required frequent calibration and continuous assistance of skilled engineers to maintain performance. Here, an individual with locked-in syndrome due to brain stem stroke and an individual with tetraplegia secondary to amyotrophic lateral sclerosis (ALS) used a simple communication BCI based on intracortical local field potentials (LFPs) for 76 and 138 days, respectively, without recalibration and without significant loss of performance. BCI spelling rates of 3.07 and 6.88 correct characters/minute allowed the participants to type messages and write emails. Our results indicate that people with locked-in syndrome could soon use a slow but reliable LFP-based BCI for everyday communication without ongoing intervention from a technician or caregiver. NEW & NOTEWORTHY This study demonstrates, for the first time, stable repeated use of an intracortical brain-computer interface by people with tetraplegia over up to four and a half months. The approach uses local field potentials (LFPs), signals that may be more stable than neuronal action potentials, to decode participants' commands. Throughout the several months of evaluation, the decoder remained unchanged; thus no technical interventions were required to maintain consistent brain-computer interface operation.


Subject(s)
Amyotrophic Lateral Sclerosis/rehabilitation , Brain-Computer Interfaces , Communication , Quadriplegia/rehabilitation , Stroke Rehabilitation/methods , Stroke/physiopathology , Amyotrophic Lateral Sclerosis/complications , Amyotrophic Lateral Sclerosis/physiopathology , Brain Stem/physiopathology , Evoked Potentials , Humans , Quadriplegia/physiopathology , Stroke/etiology , Stroke Rehabilitation/instrumentation
8.
J Neurophysiol ; 119(6): 2212-2228, 2018 06 01.
Article in English | MEDLINE | ID: mdl-29442553

ABSTRACT

Previous studies on the origin and properties of spatial patterns in motor cortex ß-local field potential (ß-LFP) oscillations have focused on planar traveling waves. However, it is unclear 1) whether ß-LFP waves are limited to plane waves, or even 2) whether they are propagating waves of excito-excitatory activity, i.e., primarily traveling waves in excitable media; they could reflect, instead, reorganization in the relative phases of transient oscillations at different spatial sites. We addressed these two problems in ß-LFPs recorded via microelectrode arrays implanted in three adjacent motor cortex areas of nonhuman primates during steady-state movement preparation. Our findings are fourfold: 1) ß-LFP wave patterns emerged as transient events, despite stable firing rates of single neurons concurrently recorded during the same periods. 2) ß-LFP waves showed a richer variety of spatial dynamics, including rotating and complex waves. 3) ß-LFP wave patterns showed no characteristic wavelength, presenting instead a range of scales with global zero-lag phase synchrony as a limiting case, features surprising for purely excito-excitatory waves but consistent with waves in coupled oscillator systems. 4) Furthermore, excito-excitatory traveling waves induced by optogenetic stimulation in motor cortex showed, in contrast, a characteristic wavelength and reduced phase synchrony. Overall, ß-LFP wave statistics differed from those of induced traveling waves in excitable media recorded under the same microelectrode array setup. Our findings suggest phase reorganization in neural coupled oscillators contribute significantly to the origin of transient ß-LFP spatial dynamics during preparatory steady states and outline important constraints for spatially extended models of ß-LFP dynamics in motor cortex. NEW & NOTEWORTHY We show that a rich variety of transient ß-local field potential (ß-LFP) wave patterns emerge in motor cortex during preparatory steady states, despite stable neuronal firing rates. Furthermore, unlike optogenetically induced traveling waves, ß-LFP waves showed no characteristic wavelength, presenting instead a range of scales with global phase synchrony as a limiting case. Overall, our statistical analyses suggest that transient phase reorganization in neural coupled oscillators, beyond purely excito-excitatory traveling waves, contribute significantly to the origin of motor cortex ß-LFP wave patterns.


Subject(s)
Beta Rhythm , Motor Cortex/physiology , Movement , Animals , Macaca mulatta
9.
Lancet ; 389(10081): 1821-1830, 2017 05 06.
Article in English | MEDLINE | ID: mdl-28363483

ABSTRACT

BACKGROUND: People with chronic tetraplegia, due to high-cervical spinal cord injury, can regain limb movements through coordinated electrical stimulation of peripheral muscles and nerves, known as functional electrical stimulation (FES). Users typically command FES systems through other preserved, but unrelated and limited in number, volitional movements (eg, facial muscle activity, head movements, shoulder shrugs). We report the findings of an individual with traumatic high-cervical spinal cord injury who coordinated reaching and grasping movements using his own paralysed arm and hand, reanimated through implanted FES, and commanded using his own cortical signals through an intracortical brain-computer interface (iBCI). METHODS: We recruited a participant into the BrainGate2 clinical trial, an ongoing study that obtains safety information regarding an intracortical neural interface device, and investigates the feasibility of people with tetraplegia controlling assistive devices using their cortical signals. Surgical procedures were performed at University Hospitals Cleveland Medical Center (Cleveland, OH, USA). Study procedures and data analyses were performed at Case Western Reserve University (Cleveland, OH, USA) and the US Department of Veterans Affairs, Louis Stokes Cleveland Veterans Affairs Medical Center (Cleveland, OH, USA). The study participant was a 53-year-old man with a spinal cord injury (cervical level 4, American Spinal Injury Association Impairment Scale category A). He received two intracortical microelectrode arrays in the hand area of his motor cortex, and 4 months and 9 months later received a total of 36 implanted percutaneous electrodes in his right upper and lower arm to electrically stimulate his hand, elbow, and shoulder muscles. The participant used a motorised mobile arm support for gravitational assistance and to provide humeral abduction and adduction under cortical control. We assessed the participant's ability to cortically command his paralysed arm to perform simple single-joint arm and hand movements and functionally meaningful multi-joint movements. We compared iBCI control of his paralysed arm with that of a virtual three-dimensional arm. This study is registered with ClinicalTrials.gov, number NCT00912041. FINDINGS: The intracortical implant occurred on Dec 1, 2014, and we are continuing to study the participant. The last session included in this report was Nov 7, 2016. The point-to-point target acquisition sessions began on Oct 8, 2015 (311 days after implant). The participant successfully cortically commanded single-joint and coordinated multi-joint arm movements for point-to-point target acquisitions (80-100% accuracy), using first a virtual arm and second his own arm animated by FES. Using his paralysed arm, the participant volitionally performed self-paced reaches to drink a mug of coffee (successfully completing 11 of 12 attempts within a single session 463 days after implant) and feed himself (717 days after implant). INTERPRETATION: To our knowledge, this is the first report of a combined implanted FES+iBCI neuroprosthesis for restoring both reaching and grasping movements to people with chronic tetraplegia due to spinal cord injury, and represents a major advance, with a clear translational path, for clinically viable neuroprostheses for restoration of reaching and grasping after paralysis. FUNDING: National Institutes of Health, Department of Veterans Affairs.


Subject(s)
Brain-Computer Interfaces/statistics & numerical data , Brain/physiopathology , Hand Strength/physiology , Muscle, Skeletal/physiopathology , Quadriplegia/diagnosis , Spinal Cord Injuries/physiopathology , Brain/surgery , Electric Stimulation Therapy/methods , Electrodes, Implanted/standards , Feasibility Studies , Hand/physiology , Humans , Male , Microelectrodes/adverse effects , Middle Aged , Motor Cortex/physiopathology , Movement/physiology , Quadriplegia/physiopathology , Quadriplegia/surgery , Self-Help Devices/statistics & numerical data , Spinal Cord Injuries/therapy , United States , United States Department of Veterans Affairs , User-Computer Interface
10.
J Neurophysiol ; 117(4): 1524-1543, 2017 04 01.
Article in English | MEDLINE | ID: mdl-28100654

ABSTRACT

Determining the relationship between single-neuron spiking and transient (20 Hz) ß-local field potential (ß-LFP) oscillations is an important step for understanding the role of these oscillations in motor cortex. We show that whereas motor cortex firing rates and beta spiking rhythmicity remain sustained during steady-state movement preparation periods, ß-LFP oscillations emerge, in contrast, as short transient events. Single-neuron mean firing rates within and outside transient ß-LFP events showed no differences, and no consistent correlation was found between the beta oscillation amplitude and firing rates, as was the case for movement- and visual cue-related ß-LFP suppression. Importantly, well-isolated single units featuring beta-rhythmic spiking (43%, 125/292) showed no apparent or only weak phase coupling with the transient ß-LFP oscillations. Similar results were obtained for the population spiking. These findings were common in triple microelectrode array recordings from primary motor (M1), ventral (PMv), and dorsal premotor (PMd) cortices in nonhuman primates during movement preparation. Although beta spiking rhythmicity indicates strong membrane potential fluctuations in the beta band, it does not imply strong phase coupling with ß-LFP oscillations. The observed dissociation points to two different sources of variation in motor cortex ß-LFPs: one that impacts single-neuron spiking dynamics and another related to the generation of mesoscopic ß-LFP signals. Furthermore, our findings indicate that rhythmic spiking and diverse neuronal firing rates, which encode planned actions during movement preparation, may naturally limit the ability of different neuronal populations to strongly phase-couple to a single dominant oscillation frequency, leading to the observed spiking and ß-LFP dissociation.NEW & NOTEWORTHY We show that whereas motor cortex spiking rates and beta (~20 Hz) spiking rhythmicity remain sustained during steady-state movement preparation periods, ß-local field potential (ß-LFP) oscillations emerge, in contrast, as transient events. Furthermore, the ß-LFP phase at which neurons spike drifts: phase coupling is typically weak or absent. This dissociation points to two sources of variation in the level of motor cortex beta: one that impacts single-neuron spiking and another related to the generation of measured mesoscopic ß-LFPs.


Subject(s)
Action Potentials/physiology , Beta Rhythm/physiology , Hand Strength/physiology , Motor Cortex/cytology , Motor Cortex/physiology , Neurons/physiology , Animals , Cues , Macaca mulatta , Male , Microelectrodes , Movement , Photic Stimulation
11.
J Neural Eng ; 13(2): 026003, 2016 Apr.
Article in English | MEDLINE | ID: mdl-26824680

ABSTRACT

OBJECTIVE: Signal attenuation is a major problem facing intracortical sensors for chronic neuroprosthetic applications. Many studies suggest that failure is due to gliosis around the electrode tips, however, mechanical and material causes of failure are often overlooked. The purpose of this study was to investigate the factors contributing to progressive signal decline by using scanning electron microscopy (SEM) to visualize structural changes in chronically implanted arrays and histology to examine the tissue response at corresponding implant sites. APPROACH: We examined eight chronically implanted intracortical microelectrode arrays (MEAs) explanted from non-human primates at times ranging from 37 to 1051 days post-implant. We used SEM, in vivo neural recordings, and histology (GFAP, Iba-1, NeuN). Three MEAs that were never implanted were also imaged as controls. MAIN RESULTS: SEM revealed progressive corrosion of the platinum electrode tips and changes to the underlying silicon. The parylene insulation was prone to cracking and delamination, and in some instances the silicone elastomer also delaminated from the edges of the MEA. Substantial tissue encapsulation was observed and was often seen growing into defects in the platinum and parylene. These material defects became more common as the time in vivo increased. Histology at 37 and 1051 days post-implant showed gliosis, disruption of normal cortical architecture with minimal neuronal loss, and high Iba-1 reactivity, especially within the arachnoid and dura. Electrode tracts were either absent or barely visible in the cortex at 1051 days, but were seen in the fibrotic encapsulation material suggesting that the MEAs were lifted out of the brain. Neural recordings showed a progressive drop in impedance, signal amplitude, and viable channels over time. SIGNIFICANCE: These results provide evidence that signal loss in MEAs is truly multifactorial. Gliosis occurs in the first few months after implantation but does not prevent useful recordings for several years. Progressive meningeal fibrosis encapsulates and lifts MEAs out of the cortex while ongoing foreign body reactions lead to progressive degradation of the materials. Long-term impedance drops are due to the corrosion of platinum, cracking and delamination of parylene, and delamination of silicone elastomer. Oxygen radicals released by cells of the immune system likely mediate the degradation of these materials. Future MEA designs must address these problems through more durable insulation materials, more inert electrode alloys, and pharmacologic suppression of fibroblasts and leukocytes.


Subject(s)
Electrodes, Implanted , Equipment Design/methods , Microelectrodes , Microscopy, Electron, Scanning/methods , Motor Cortex/physiology , Animals , Electrodes, Implanted/standards , Equipment Design/standards , Female , Macaca mulatta , Male , Microelectrodes/standards , Microscopy, Electron, Scanning/standards , Primates
12.
Sci Transl Med ; 7(313): 313ra179, 2015 Nov 11.
Article in English | MEDLINE | ID: mdl-26560357

ABSTRACT

Brain-computer interfaces (BCIs) promise to restore independence for people with severe motor disabilities by translating decoded neural activity directly into the control of a computer. However, recorded neural signals are not stationary (that is, can change over time), degrading the quality of decoding. Requiring users to pause what they are doing whenever signals change to perform decoder recalibration routines is time-consuming and impractical for everyday use of BCIs. We demonstrate that signal nonstationarity in an intracortical BCI can be mitigated automatically in software, enabling long periods (hours to days) of self-paced point-and-click typing by people with tetraplegia, without degradation in neural control. Three key innovations were included in our approach: tracking the statistics of the neural activity during self-timed pauses in neural control, velocity bias correction during neural control, and periodically recalibrating the decoder using data acquired during typing by mapping neural activity to movement intentions that are inferred retrospectively based on the user's self-selected targets. These methods, which can be extended to a variety of neurally controlled applications, advance the potential for intracortical BCIs to help restore independent communication and assistive device control for people with paralysis.


Subject(s)
Brain-Computer Interfaces , Quadriplegia/physiopathology , Quadriplegia/rehabilitation , Self-Help Devices , Amyotrophic Lateral Sclerosis/complications , Calibration , Female , Humans , Male , Motor Cortex/physiopathology , Stroke/complications
13.
J Neurosci ; 35(30): 10888-97, 2015 Jul 29.
Article in English | MEDLINE | ID: mdl-26224870

ABSTRACT

Neural activity in ventral premotor cortex (PMv) has been associated with the process of matching perceived objects with the motor commands needed to grasp them. It remains unclear how PMv networks can flexibly link percepts of objects affording multiple grasp options into a final desired hand action. Here, we use a relational encoding approach to track the functional state of PMv neuronal ensembles in macaque monkeys through the process of passive viewing, grip planning, and grasping movement execution. We used objects affording multiple possible grip strategies. The task included separate instructed delay periods for object presentation and grip instruction. This approach allowed us to distinguish responses elicited by the visual presentation of the objects from those associated with selecting a given motor plan for grasping. We show that PMv continuously incorporates information related to object shape and grip strategy as it becomes available, revealing a transition from a set of ensemble states initially most closely related to objects, to a new set of ensemble patterns reflecting unique object-grip combinations. These results suggest that PMv dynamically combines percepts, gradually navigating toward activity patterns associated with specific volitional actions, rather than directly mapping perceptual object properties onto categorical grip representations. Our results support the idea that PMv is part of a network that dynamically computes motor plans from perceptual information. SIGNIFICANCE STATEMENT: The present work demonstrates that the activity of groups of neurons in primate ventral premotor cortex reflects information related to visually presented objects, as well as the motor strategy used to grasp them, linking individual objects to multiple possible grips. PMv could provide useful control signals for neuroprosthetic assistive devices designed to interact with objects in a flexible way.


Subject(s)
Hand Strength/physiology , Motor Cortex/physiology , Psychomotor Performance/physiology , Action Potentials/physiology , Animals , Electrophysiology , Macaca , Male , Neurons/physiology
14.
Front Syst Neurosci ; 9: 89, 2015.
Article in English | MEDLINE | ID: mdl-26157365

ABSTRACT

Understanding the sources of variability in single-neuron spiking responses is an important open problem for the theory of neural coding. This variability is thought to result primarily from spontaneous collective dynamics in neuronal networks. Here, we investigate how well collective dynamics reflected in motor cortex local field potentials (LFPs) can account for spiking variability during motor behavior. Neural activity was recorded via microelectrode arrays implanted in ventral and dorsal premotor and primary motor cortices of non-human primates performing naturalistic 3-D reaching and grasping actions. Point process models were used to quantify how well LFP features accounted for spiking variability not explained by the measured 3-D reach and grasp kinematics. LFP features included the instantaneous magnitude, phase and analytic-signal components of narrow band-pass filtered (δ,θ,α,ß) LFPs, and analytic signal and amplitude envelope features in higher-frequency bands. Multiband LFP features predicted single-neuron spiking (1ms resolution) with substantial accuracy as assessed via ROC analysis. Notably, however, models including both LFP and kinematics features displayed marginal improvement over kinematics-only models. Furthermore, the small predictive information added by LFP features to kinematic models was redundant to information available in fast-timescale (<100 ms) spiking history. Overall, information in multiband LFP features, although predictive of single-neuron spiking during movement execution, was redundant to information available in movement parameters and spiking history. Our findings suggest that, during movement execution, collective dynamics reflected in motor cortex LFPs primarily relate to sensorimotor processes directly controlling movement output, adding little explanatory power to variability not accounted by movement parameters.

15.
Philos Trans R Soc Lond B Biol Sci ; 370(1668)2015 May 19.
Article in English | MEDLINE | ID: mdl-25823863

ABSTRACT

The evolution of the field of neuroscience has been propelled by the advent of novel technological capabilities, and the pace at which these capabilities are being developed has accelerated dramatically in the past decade. Capitalizing on this momentum, the United States launched the Brain Research through Advancing Innovative Neurotechnologies (BRAIN) Initiative to develop and apply new tools and technologies for revolutionizing our understanding of the brain. In this article, we review the scientific vision for this initiative set forth by the National Institutes of Health and discuss its implications for the future of neuroscience research. Particular emphasis is given to its potential impact on the mapping and study of neural circuits, and how this knowledge will transform our understanding of the complexity of the human brain and its diverse array of behaviours, perceptions, thoughts and emotions.


Subject(s)
Brain Mapping/methods , Nerve Net/anatomy & histology , Neurosciences/methods , Humans , Research Design
16.
J Neurosci Methods ; 244: 94-103, 2015 Apr 15.
Article in English | MEDLINE | ID: mdl-25681017

ABSTRACT

BACKGROUND: Multiple types of neural signals are available for controlling assistive devices through brain-computer interfaces (BCIs). Intracortically recorded spiking neural signals are attractive for BCIs because they can in principle provide greater fidelity of encoded information compared to electrocorticographic (ECoG) signals and electroencephalograms (EEGs). Recent reports show that the information content of these spiking neural signals can be reliably extracted simply by causally band-pass filtering the recorded extracellular voltage signals and then applying a spike detection threshold, without relying on "sorting" action potentials. NEW METHOD: We show that replacing the causal filter with an equivalent non-causal filter increases the information content extracted from the extracellular spiking signal and improves decoding of intended movement direction. This method can be used for real-time BCI applications by using a 4ms lag between recording and filtering neural signals. RESULTS: Across 18 sessions from two people with tetraplegia enrolled in the BrainGate2 pilot clinical trial, we found that threshold crossing events extracted using this non-causal filtering method were significantly more informative of each participant's intended cursor kinematics compared to threshold crossing events derived from causally filtered signals. This new method decreased the mean angular error between the intended and decoded cursor direction by 9.7° for participant S3, who was implanted 5.4 years prior to this study, and by 3.5° for participant T2, who was implanted 3 months prior to this study. CONCLUSIONS: Non-causally filtering neural signals prior to extracting threshold crossing events may be a simple yet effective way to condition intracortically recorded neural activity for direct control of external devices through BCIs.

17.
IEEE Trans Biomed Eng ; 62(2): 570-81, 2015 Feb.
Article in English | MEDLINE | ID: mdl-25265627

ABSTRACT

Rapid developments in neural interface technology are making it possible to record increasingly large signal sets of neural activity. Various factors such as asymmetrical information distribution and across-channel redundancy may, however, limit the benefit of high-dimensional signal sets, and the increased computational complexity may not yield corresponding improvement in system performance. High-dimensional system models may also lead to overfitting and lack of generalizability. To address these issues, we present a generalized modulation depth measure using the state-space framework that quantifies the tuning of a neural signal channel to relevant behavioral covariates. For a dynamical system, we develop computationally efficient procedures for estimating modulation depth from multivariate data. We show that this measure can be used to rank neural signals and select an optimal channel subset for inclusion in the neural decoding algorithm. We present a scheme for choosing the optimal subset based on model order selection criteria. We apply this method to neuronal ensemble spike-rate decoding in neural interfaces, using our framework to relate motor cortical activity with intended movement kinematics. With offline analysis of intracortical motor imagery data obtained from individuals with tetraplegia using the BrainGate neural interface, we demonstrate that our variable selection scheme is useful for identifying and ranking the most information-rich neural signals. We demonstrate that our approach offers several orders of magnitude lower complexity but virtually identical decoding performance compared to greedy search and other selection schemes. Our statistical analysis shows that the modulation depth of human motor cortical single-unit signals is well characterized by the generalized Pareto distribution. Our variable selection scheme has wide applicability in problems involving multisensor signal modeling and estimation in biomedical engineering systems.


Subject(s)
Action Potentials , Electroencephalography/methods , Models, Neurological , Motor Cortex/physiopathology , Quadriplegia/physiopathology , Computer Simulation , Data Interpretation, Statistical , Electrodes , Electroencephalography/instrumentation , Humans , Models, Statistical , Motor Neurons , Quadriplegia/diagnosis , Reproducibility of Results , Sensitivity and Specificity
18.
Neural Comput ; 27(1): 1-31, 2015 Jan.
Article in English | MEDLINE | ID: mdl-25380335

ABSTRACT

Increased emphasis on circuit level activity in the brain makes it necessary to have methods to visualize and evaluate large-scale ensemble activity beyond that revealed by raster-histograms or pairwise correlations. We present a method to evaluate the relative similarity of neural spiking patterns by combining spike train distance metrics with dimensionality reduction. Spike train distance metrics provide an estimate of similarity between activity patterns at multiple temporal resolutions. Vectors of pair-wise distances are used to represent the intrinsic relationships between multiple activity patterns at the level of single units or neuronal ensembles. Dimensionality reduction is then used to project the data into concise representations suitable for clustering analysis as well as exploratory visualization. Algorithm performance and robustness are evaluated using multielectrode ensemble activity data recorded in behaving primates. We demonstrate how spike train SIMilarity space (SSIMS) analysis captures the relationship between goal directions for an eight-directional reaching task and successfully segregates grasp types in a 3D grasping task in the absence of kinematic information. The algorithm enables exploration of virtually any type of neural spiking (time series) data, providing similarity-based clustering of neural activity states with minimal assumptions about potential information encoding models.


Subject(s)
Action Potentials/physiology , Cerebral Cortex/cytology , Models, Neurological , Neurons/physiology , Space Perception/physiology , Algorithms , Animals , Computer Simulation , Humans , Neural Networks, Computer
19.
J Neurophysiol ; 112(11): 2959-84, 2014 Dec 01.
Article in English | MEDLINE | ID: mdl-25210154

ABSTRACT

Neural interactions between parietal area 2/5 and primary motor cortex (M1) were examined to determine the timing and behavioral correlates of cortico-cortical interactions. Neural activity in areas 2/5 and M1 was simultaneously recorded with 96-channel microelectrode arrays in three rhesus monkeys performing a center-out reach task. We introduce a new method to reveal parietal-motor interactions at a population level using partial spike-field coherence (PSFC) between ensembles of neurons in one area and a local field potential (LFP) in another. PSFC reflects the extent of phase locking between spike times and LFP, after removing the coherence between LFPs in the two areas. Spectral analysis of M1 LFP revealed three bands: low, medium, and high, differing in power between movement preparation and performance. We focus on PSFC in the 1-10 Hz band, in which coherence was strongest. PSFC was also present in the 10-40 Hz band during movement preparation in many channels but generally nonsignificant in the 60-200 Hz band. Ensemble PSFC revealed stronger interactions than single cell-LFP pairings. PSFC of area 2/5 ensembles with M1 LFP typically rose around movement onset and peaked ∼500 ms afterward. PSFC was typically stronger for subsets of area 2/5 neurons and M1 LFPs with similar directional bias than for those with opposite bias, indicating that area 2/5 contributes movement direction information. Together with linear prediction of M1 LFP by area 2/5 spiking, the ensemble-LFP pairing approach reveals interactions missed by single neuron-LFP pairing, demonstrating that cortico-cortical communication can be more readily observed at the ensemble level.


Subject(s)
Motor Cortex/physiology , Motor Skills , Neurons/physiology , Parietal Lobe/physiology , Action Potentials , Animals , Macaca mulatta , Motor Cortex/cytology , Parietal Lobe/cytology , Synaptic Potentials
20.
J Neurosci Methods ; 236: 58-67, 2014 Oct 30.
Article in English | MEDLINE | ID: mdl-25128256

ABSTRACT

BACKGROUND: Multiple types of neural signals are available for controlling assistive devices through brain-computer interfaces (BCIs). Intracortically recorded spiking neural signals are attractive for BCIs because they can in principle provide greater fidelity of encoded information compared to electrocorticographic (ECoG) signals and electroencephalograms (EEGs). Recent reports show that the information content of these spiking neural signals can be reliably extracted simply by causally band-pass filtering the recorded extracellular voltage signals and then applying a spike detection threshold, without relying on "sorting" action potentials. NEW METHOD: We show that replacing the causal filter with an equivalent non-causal filter increases the information content extracted from the extracellular spiking signal and improves decoding of intended movement direction. This method can be used for real-time BCI applications by using a 4ms lag between recording and filtering neural signals. RESULTS: Across 18 sessions from two people with tetraplegia enrolled in the BrainGate2 pilot clinical trial, we found that threshold crossing events extracted using this non-causal filtering method were significantly more informative of each participant's intended cursor kinematics compared to threshold crossing events derived from causally filtered signals. This new method decreased the mean angular error between the intended and decoded cursor direction by 9.7° for participant S3, who was implanted 5.4 years prior to this study, and by 3.5° for participant T2, who was implanted 3 months prior to this study. CONCLUSIONS: Non-causally filtering neural signals prior to extracting threshold crossing events may be a simple yet effective way to condition intracortically recorded neural activity for direct control of external devices through BCIs.


Subject(s)
Action Potentials , Brain-Computer Interfaces , Brain/physiopathology , Motor Activity/physiology , Signal Processing, Computer-Assisted , Aged , Biomechanical Phenomena , Electrodes, Implanted , Female , Humans , Male , Middle Aged , Neuropsychological Tests , Pilot Projects , Quadriplegia/physiopathology , Quadriplegia/therapy
SELECTION OF CITATIONS
SEARCH DETAIL
...