Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Stapp Car Crash J ; 63: 235-266, 2019 Nov.
Article in English | MEDLINE | ID: mdl-32311059

ABSTRACT

Limited data exist on the injury tolerance and biomechanical response of humans to high-rate, under-body blast (UBB) loading conditions that are commonly seen in current military operations, and there are no data examining the influence of occupant posture on response. Additionally, no anthropomorphic test device (ATD) currently exists that can properly assess the response of humans to high-rate UBB loading. Therefore, the purpose of this research was to examine the response of post-mortem human surrogates (PMHS) in various seated postures to high-rate, vertical loading representative of those conditions seen in theater. In total, six PMHS tests were conducted using loading pulses applied directly to the pelvis and feet of the PMHS: three in an acute posture (foot, knee, and pelvis angles of 75°, 75°, and 36°, respectively), and three in an obtuse posture (15° reclined torso, and foot, knee, and pelvis angles of 105°, 105°, and 49.5°, respectively). Tests were conducted with a seat velocity pulse that peaked at ~4 m/s with a 30-40 ms time to peak velocity (TTP) and a floor velocity that peaked at 6.9-8.0 m/s (2-2.75 ms TTP). Posture condition had no influence on skeletal injuries sustained, but did result in altered leg kinematics, with leg entrapment under the seat occurring in the acute posture, and significant forward leg rotations occurring in the obtuse posture. These data will be used to validate a prototype ATD meant for use in high-rate UBB loading scenarios.


Subject(s)
Explosions , Motor Vehicles , Posture , Accidents, Traffic , Autopsy , Biomechanical Phenomena , Cadaver , Humans , Research Subjects
2.
J Biomech ; 72: 258-261, 2018 04 27.
Article in English | MEDLINE | ID: mdl-29571599

ABSTRACT

Biological tissue testing is inherently susceptible to the wide range of variability specimen to specimen. A primary resource for encapsulating this range of variability is the biofidelity response corridor or BRC. In the field of injury biomechanics, BRCs are often used for development and validation of both physical, such as anthropomorphic test devices, and computational models. For the purpose of generating corridors, post-mortem human surrogates were tested across a range of loading conditions relevant to under-body blast events. To sufficiently cover the wide range of input conditions, a relatively small number of tests were performed across a large spread of conditions. The high volume of required testing called for leveraging the capabilities of multiple impact test facilities, all with slight variations in test devices. A method for assessing similitude of responses between test devices was created as a metric for inclusion of a response in the resulting BRC. The goal of this method was to supply a statistically sound, objective method to assess the similitude of an individual response against a set of responses to ensure that the BRC created from the set was affected primarily by biological variability, not anomalies or differences stemming from test devices.


Subject(s)
Cadaver , Explosions , Biomechanical Phenomena , Humans , Individuality
3.
Stapp Car Crash J ; 60: 199-246, 2016 11.
Article in English | MEDLINE | ID: mdl-27871099

ABSTRACT

Three laboratory simulated sub-injurious under-body blast (UBB) test conditions were conducted with whole-body Post Mortem Human Surrogates (PMHS) and the Warrior Assessment Injury Manikin (WIAMan) Technology Demonstrator (TD) to establish and assess UBB biofidelity of the WIAMan TD. Test conditions included a rigid floor and rigid seat with independently varied pulses. On the floor, peak velocities of 4 m/s and 6 m/s were applied with a 5 ms time to peak (TTP). The seat peak velocity was 4 m/s with varied TTP of 5 and 10 ms. Tests were conducted with and without personal protective equipment (PPE). PMHS response data was compiled into preliminary biofidelity response corridors (BRCs), which served as evaluation metrics for the WIAMan TD. Each WIAMan TD response was evaluated against the PMHS preliminary BRC for the loading and unloading phase of the signal time history using Correlation Analysis (CORA) software to assign a numerical score between 0 and 1. A weighted average of all responses was calculated to determine body region and whole body biofidelity scores for each test condition. The WIAMan TD received UBB biofidelity scores of 0.62 in Condition A, 0.59 in Condition B, and 0.63 in Condition C, putting it in the fair category (0.44-0.65). Body region responses with scores below a rating of good (0.65-0.84) indicate potential focus areas for the next generation of the WIAMan design.


Subject(s)
Cadaver , Explosions , Manikins , Acceleration , Biomechanical Phenomena , Humans , Male , Models, Biological
SELECTION OF CITATIONS
SEARCH DETAIL
...