Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add more filters










Database
Language
Publication year range
1.
J Pharm Biomed Anal ; 150: 51-58, 2018 Feb 20.
Article in English | MEDLINE | ID: mdl-29216585

ABSTRACT

Irinotecan (IRI) is an antineoplastic drug widely used for the treatment of colorectal and advanced pancreatic cancer. Despite its clinical utility, the clinical use of IRI is associated with potentially severe hematopoietic and gastrointestinal toxicities. The quantification of IRI and its active metabolite SN-38 in dried blood spots (DBS) may be an alternative to individualize the drug dose through a minimally invasive and easy collection method. The aim of this study was to develop and validate a simple and fast HPLC-FL assay for simultaneous IRI and SN-38 measurement in DBS, with adequate analytical performance for clinical use. The method employs liquid extraction of one 8mm disk of whole blood, followed by separation in a reversed phase Eclipse Plus C8 column (150×4.6mm, 5µm). Detection was performed with a fluorescence detector, with excitation wavelength of 370 and emission of 420 for IRI and 540nm for SN-38 and internal standard (camptothecin). Total analytical run time was 17min. Mobile phase was a mixture of 0.1M phosphate buffer pH 4.0 and acetonitrile (80:20, v/v), at 1mLmin-1. The assay was linear in the range 10-3,000ngmL-1 and from 0.5 to 300ngmL-1 for IRI and SN-38, respectively. Precision assays presented CV% of 2.71-5.65 and 2.15-10.07 for IRI and SN-38, respectively, and accuracy in the range of 94.26-100.93 and 94.24-99.33%. IRI and SN-38 were stable at 25 and 42°C for 14days in DBS samples. The method was applied to DBS samples obtained from fingerpicks from 19 volunteers receiving IRI in single or combined chemotherapy regimens, collected 1 and 24h after beginning of the infusion. The estimated plasma concentration of IRI and SN-38 in sample collected 1h after star of infusion had 16 of 19 values within the ±20% range of the measured plasma concentrations. On the other hand, predictions of IRI and SN-38 plasma concentrations from DBS measurements obtained 24h after the beginning of the infusion were poor. AUC of IRI that was calculated using plasma and DBS-estimated concentrations, with a high correlation (r=0.918). The method presented suitable characteristics for the clinical use. However, translation of IRI and SN-38 DBS to plasma concentrations is challenging due to the compound's variable plasma/blood partition.


Subject(s)
Antineoplastic Agents, Phytogenic/pharmacokinetics , Camptothecin/analogs & derivatives , Chromatography, High Pressure Liquid/methods , Dried Blood Spot Testing/methods , Antineoplastic Agents, Phytogenic/administration & dosage , Area Under Curve , Camptothecin/administration & dosage , Camptothecin/pharmacokinetics , Drug Monitoring/methods , Drug Stability , Fluorescence , Humans , Irinotecan , Reproducibility of Results , Temperature , Time Factors
SELECTION OF CITATIONS
SEARCH DETAIL
...