Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 9 de 9
Filter
Add more filters










Database
Language
Publication year range
1.
Environ Sci Technol ; 57(38): 14363-14372, 2023 09 26.
Article in English | MEDLINE | ID: mdl-37715305

ABSTRACT

The abiotic fate of dissolved free amino acids considerably contributes to the cycling of dissolved sulfur and nitrogen in natural aquatic environments. However, the roles of the functional groups of chromophoric dissolved organic matter (CDOM) and the fate of free amino acids under sunlight irradiation in fresh waters are not fully understood. This study aims to elucidate the fate of photolabile methionine in the presence of three CDOM surrogate compounds, i.e., 1,4-naphthoquinone, 2-naphthaldehyde, and umbelliferone, and two standard CDOM by coupling experimental measurement, quantum chemical computations, and kinetic modeling. Results indicate that excited triplet-state CDOM and hydroxyl radicals are able to cleave the C-S bond in methionine, resulting in the formation of smaller amino acids and volatile sulfur-containing compounds. Singlet oxygen forms methionine sulfoxide and methionine sulfone. The distribution of phototransformation products offers an improved understanding of the fate of nitrogen- and sulfur-containing compounds and their uptake by microorganisms in natural aquatic environments.


Subject(s)
Dissolved Organic Matter , Sunlight , Methionine , Racemethionine , Amino Acids
2.
Environ Sci Technol ; 55(12): 8054-8067, 2021 06 15.
Article in English | MEDLINE | ID: mdl-34096699

ABSTRACT

Singlet oxygen (1O2) is a selective reactive oxygen species that plays a key role for the fate of various organic compounds in the aquatic environment under sunlight irradiation, engineered water oxidation systems, atmospheric water droplets, and biomedical systems. While the initial rate-determining charge-transfer reaction mechanisms and kinetics of 1O2 have been studied extensively, no comprehensive studies have been performed to elucidate the reaction mechanisms with organic compounds that have various functional groups. In this study, we use density functional theory calculations to determine elementary reaction mechanisms with a wide variety of organic compounds. The theoretically calculated aqueous-phase free energies of activation of single electron transfer and 1O2 addition reactions are compared to the experimentally determined rate constants in the literature to determine linear free-energy relationships. The theoretically calculated free energies of activation for the groups of phenolates and phenols show excellent correlations with the Hammett constants that accept electron densities by through-resonance. The dominant elementary reaction mechanism is discussed for each group of compounds. As a practical implication, we demonstrate the fate of environmentally relevant organic compounds induced by photochemically produced intermediate species at different pH and evaluate the impact of predicting rate constants to the half-life.


Subject(s)
Organic Chemicals , Singlet Oxygen , Kinetics , Oxidation-Reduction , Oxygen , Water
3.
J Chromatogr A ; 1418: 1-11, 2015 Oct 30.
Article in English | MEDLINE | ID: mdl-26427323

ABSTRACT

Two, 3-step methods for derivatizing mono- and multi-functional species with carbonyl (CO), carboxylic acid (-COOH), and alcohol (-OH) moieties were compared and optimized. In Method 1, the CO, -COOH, and -OH moieties were converted (1) to methyloximes (R-CN-OCH3) with O-methylhydroxylamine hydrochloride (MHA), (2) to methyl esters (OC-R-OCH3) with (trimethylsilyl)diazomethane in methanol (TMSD/MeOH), and (3) to trimethylsilyl ethers [R-OSi(CH3)3] with N,O-bis(trimethylsilyl)-trifluoroacetamide (BSTFA) containing 1% trimethylchlorosilane (TMCS), respectively. Steps 1 and 3 of both methods were identical; however, in Step 2 of Method 2, -COOH moieties were derivatized with 10% (v/v) boron trifluoride (BF3) in MeOH or n-butanol (n-BuOH). The BF3/MeOH and BF3/n-BuOH were ineffective at converting species with more than 2-OH moieties. Average standard deviations for derivatization of 36 model compounds by the 3-step methods using TMSD/MeOH and BF3/(MeOH) were 7.4 and 14.8%, respectively. Average derivatization efficiencies for Methods 1 and 2 were 88.0 and 114%, respectively. Despite the lower average derivatization efficiency of Method 1, distinct advantages included a greater certainty of derivatization yield for the entire suite of mono- and multi-functional species and fewer processing steps for sequential derivatization. Detection limits for Method 1 using GC×GC-ToF-MS were 0.3-54pgm(-3). Approximately 100 oxygenated organic species were identified and quantified in aerosol filtered from 39m(3) of air in an urban location. Levels of species were 0.013-17ngm(-3) and were nearly all above the Method 1 limit of detection.


Subject(s)
Alcohols/chemistry , Aldehydes/chemistry , Carboxylic Acids/chemistry , Ketones/chemistry , Aerosols , Alcohols/analysis , Aldehydes/analysis , Carboxylic Acids/analysis , Esters , Gas Chromatography-Mass Spectrometry/methods , Ketones/analysis , Oximes/chemistry , Oxygen , Trimethylsilyl Compounds/chemistry
4.
Environ Sci Technol ; 49(4): 2132-9, 2015 Feb 17.
Article in English | MEDLINE | ID: mdl-25588118

ABSTRACT

An enzyme-explicit denitrification model with representations for pre- and de novo synthesized enzymes was developed to improve predictions of nitrous oxide (N2O) accumulations in soil and emissions from the surface. The metabolic model of denitrification is based on dual-substrate utilization and Monod growth kinetics. Enzyme synthesis/activation was incorporated into each sequential reduction step of denitrification to regulate dynamics of the denitrifier population and the active enzyme pool, which controlled the rate function. Parameterizations were developed from observations of the dynamics of N2O production and reduction in soil incubation experiments. The model successfully reproduced the dynamics of N2O and N2 accumulation in the incubations and revealed an important regulatory effect of denitrification enzyme kinetics on the accumulation of denitrification products. Pre-synthesized denitrification enzymes contributed 20, 13, 43, and 62% of N2O that accumulated in 48 h incubations of soil collected from depths of 0-5, 5-10, 10-15, and 15-25 cm, respectively. An enzyme activity function (E) was defined to estimate the relative concentration of active enzymes and variation in response to environmental conditions. The value of E allows for activities of pre-synthesized denitrification enzymes to be differentiated from de novo synthesized enzymes. Incorporating explicit representations of denitrification enzyme kinetics into biogeochemical models is a promising approach for accurately simulating dynamics of the production and reduction of N2O in soils.


Subject(s)
Denitrification , Models, Biological , Nitrous Oxide/chemistry , Oxidoreductases/chemistry , Soil Microbiology , Soil/chemistry , Biomass , Kinetics , Nitrous Oxide/analysis , Oxidation-Reduction
5.
J Chromatogr A ; 1140(1-2): 1-12, 2007 Jan 26.
Article in English | MEDLINE | ID: mdl-17150222

ABSTRACT

A novel method for collection and analysis of vapor-phase semivolatile organic compounds (SOCs) in ambient air is presented. The method utilizes thermal desorption of SOCs trapped in diffusion denuders coupled with cryogenic preconcentration on Tenax-TA and analysis by high resolution gas chromatography (GC)-electron-capture detection (ECD). The sampling and analysis methods employ custom-fabricated multicapillary diffusion denuders, a hot gas spike (HGS) apparatus to load known quantities of thermally stable standards into diffusion denuders prior to sample collection, a custom-fabricated oven to thermally desorb SOCs from the diffusion denuder, and a programmable temperature vaporization (PTV) inlet containing a liner packed with Tenax-TA for effective preconcentration of the analytes and water management. High flow rates into the PTV inlet of 750mLmin(-1)during thermal desorption are ca. a factor of ten greater than typically used. To improve resolution and retention time stability, the thermal desorption and PTV inlet programming procedure includes three steps to prevent water from entering the analytic column while effectively transferring the analytes into the GC system. The instrumentation and procedures provide virtually complete and consistent transfer of analytes collected from ambient air into the GC evidenced by recovery of seven replicates of four internal standards of 90.7+/-4.0-120+/-23% (mean+/-95% confidence interval, CI). Retention time based compound identification is facilitated by low retention time variability with an average 95% CI of 0.024min for sixteen replicates of eight standards. Procedure details and performance metrics as well as ambient sampling results are presented.


Subject(s)
Air/analysis , Chromatography, Gas/methods , Organic Chemicals/analysis , Diffusion , Hot Temperature , Volatilization
6.
J Chromatogr A ; 1121(1): 16-22, 2006 Jul 14.
Article in English | MEDLINE | ID: mdl-16678188

ABSTRACT

Semivolatile organic compounds (SVOCs) are distributed in the atmosphere between the gas- and aerosol-phases. The low vapor pressures of some SVOCs makes thermal extraction and transfer through gas chromatographic (GC) systems difficult. We evaluated a programmable temperature vaporization (PTV) GC inlet, which served as the preconcentration module, and four open-tubular capillaries (Silcosteel- and Siltek-treated stainless steel, Silcosteel-treated stainless steel coated with 100% dimethylpolysiloxane, and deactivated fused silica) as transfer lines in a valveless, whole-sample analytic system. Thermal extraction of C(9)-C(36)n-alkanes at 300 and 320 degrees C from fused silica and quartz wool in the PTV inlet was equally efficient. Adsorptive losses of C(22)-C(36)n-alkanes to stainless steel surfaces that protruded into the PTV inlet were suspected. Thus, treatment of the outer surfaces of transfer lines is recommended for effective thermal transfer of SVOCs. Transfer efficiencies began to decline after n-C(24), n-C(28), and n-C(30) in Silcosteel-treated stainless steel, deactivated fused silica, and Siltek-treated stainless steel transfer lines, respectively. Thus, quantitative recovery at 320 degrees C of compounds with vapor pressures less than about 3 x 10(-8)Pa is not expected in valveless SVOC thermal desorption systems that use Siltek-treated stainless steel transfer lines and fused silica or quartz wool as preconcentration substrates.


Subject(s)
Aerosols/analysis , Chromatography, Gas/instrumentation , Organic Chemicals/analysis
7.
Environ Sci Technol ; 39(21): 8411-9, 2005 Nov 01.
Article in English | MEDLINE | ID: mdl-16294881

ABSTRACT

We report initial measurements of concentrations and net air-water exchange fluxes of target persistent bioaccumulative toxicants (PBTs) in Lake Superior utilizing techniques not previously applied for this purpose. Gaseous PBTs are collected in diffusion denuders containing sections of commercial chromatography columns and subsequently thermally extracted into the cooled injection inlet of a high-resolution gas chromatograph. The PBT sampling/analytical methods enable accurate determination of gas-phase PBT concentration and micrometeorological measurement of fluxes to be carried out. PBT fluxes are measured by the modified Bowen ratio technique in which sensible heat flux is related to PBT flux, with the assumption of identical transfer velocities of heat and PBTs between two heights in the atmospheric surface layer. Micrometeorological measurement of flux accounts for all sources of resistance to mass transfer, including atmospheric stability effects, surface films, waves, sea spray, and bubbles. The sensible heatflux, PBT concentration, and PBT flux measurements carried out in 14 2- or 3-h periods during seven sampling events in Lake Superior in summer and fall 2002 and spring 2003 demonstrate advantages under the constraints of the techniques. The uncertainty of the flux measurements was typically in the range from 1% to 160%. Gaseous concentrations of a-hexachlorocyclohexane (alpha-HCH) and hexachlorobenzene (HCB) over Lake Superior were in the range from 6 to 170 and 12-95 pg/m3, respectively. Fluxes out of Lake Superior were measurable in 75% of the cases in which a concentration gradient was measured, and were in the range from -0.17 to +0.064 ng/m2 x h for alpha-HCH and from -0.60 to -0.093 ng/m2 x h for HCB.


Subject(s)
Air/analysis , Environmental Monitoring/methods , Water Pollutants, Chemical/analysis , Fresh Water , Meteorological Concepts , Reference Standards
8.
J Air Waste Manag Assoc ; 49(7): 814-822, 1999 Jul.
Article in English | MEDLINE | ID: mdl-28060656

ABSTRACT

Profiles of the sources of nonmethane organic compounds (NMOCs) were developed for emissions from vehicles, petroleum fuels (gasoline, liquefied petroleum gas [LPG], and natural gas), a petroleum refinery, a smelter, and a cast iron factory in Cairo, Egypt. More than 100 hydrocarbons and oxygenated hydrocarbons were tentatively identified and quantified. Gasoline-vapor and whole-gasoline profiles could be distinguished from the other profiles by high concentrations of the C5 and C6 saturated hydrocarbons. The vehicle emission profile was similar to the whole-gasoline profile, with the exception of the unsaturated and aromatic hydrocarbons, which were present at higher concentrations in the vehicle emission profile. High levels of the C2-C4 saturated hydrocarbons, particularly n-butane, were characteristic features of the petroleum refinery emissions. The smelter and cast iron factory emissions were similar to the refinery emissions; however, the levels of benzene and toluene were greater in the former two sources. The LPG and natural gas emissions contained high concentrations of n-butane and ethane, respectively. The NMOC source profiles for Cairo were distinctly different from profiles for U.S. sources, indicating that NMOC source profiles are sensitive to the particular composition of petroleum fuels that are used in a location.

9.
J Air Waste Manag Assoc ; 46(11): 1081-1085, 1996 Nov.
Article in English | MEDLINE | ID: mdl-28071520

ABSTRACT

Materials that will be used to construct an in situ, on-line purging system for the cone penetrometer were evaluated. Transfer efficiencies for volatile organic compounds (VOCs) through stainless steel, nickel, aluminum, and Teflon® tubings were determined using a gas-phase mixture of VOCs containing trichloromethane, tetrachloromethane, 1,1,1- trichloroethane, tetrachloroethene, hexane, benzene, toluene, and 1,2-dimethylbenzene. The water content of the gas stream had an insignificant effect on the quantitative transfer of VOCs through Teflon® tubing but was critical to efficiently transfer the compounds through metal tubing, particularly nickel. Transfer efficiencies for all eight analytes in moist gas streams through stainless steel were greater than 95%. Toluene, tetrachloroethene, and 1,2-dimethylbenzene were transferred with 93%, 81%, and 80% efficiency, respectively, when they were drawn through Teflon® PFA (perfluoroalkoxy) tubing. In general, the retention of the VOCs by Teflon® increases with decreasing aqueous solubility of the analyte. The efficiencies at which VOCs were purged from aqueous standards in Teflon® PFA, Type 304 stainless steel, and glass vessels were similar. Stainless steel was superior to nickel, aluminum, and the Teflon® polymers as a material for an in situ, on-line purging system for the cone penetrometer.

SELECTION OF CITATIONS
SEARCH DETAIL
...