Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
J Clin Med ; 12(6)2023 Mar 09.
Article in English | MEDLINE | ID: mdl-36983141

ABSTRACT

One of the crucial tasks for the planning of surgery of the iliosacral joint is placing an iliosacral screw with the goal of fixing broken parts of the pelvis. Tracking of proper screw trajectory is usually done in the preoperative phase by the acquisition of X-ray images under different angles, which guide the surgeons to perform surgery. This approach is standardly complicated due to the investigation of 2D X-ray images not showing spatial perspective. Therefore, in this pilot study, we propose complex software tools which are aimed at making a simulation model of reconstructed CT (DDR) images with a virtual iliosacral screw to guide the surgery process. This pilot study presents the testing for two clinical cases to reveal the initial performance and usability of this software in clinical conditions. This model is consequently used for a multiregional registration with reference intraoperative X-ray images to select the slide from the 3D dataset which best fits with reference X-ray. The proposed software solution utilizes input CT slices of the pelvis area to create a segmentation model of individual bone components. Consequently, a model of an iliosacral screw is inserted into this model. In the next step, we propose the software CT2DDR which makes DDR projections with the iliosacral screw. In the last step, we propose a multimodal registration procedure, which performs registration of a selected number of slices with reference X-ray, and based on the Structural Similarity Index (SSIM) and index of correlation, the procedure finds the best match of DDR with X-ray images. In this pilot study, we also provide a comparative analysis of the computational costs of the multimodal registration upon various numbers of DDR slices to show the complex software performance. The proposed complex model has versatile usage for modeling and surgery planning of the pelvis area in fractures of iliosacral joints.

2.
Materials (Basel) ; 16(2)2023 Jan 09.
Article in English | MEDLINE | ID: mdl-36676374

ABSTRACT

Anodization coloring of titanium tools or implants is one of the common methods for the differentiation of each application by its size or type. Commercial purity titanium grade 4 plates (50 × 20 × 0.1 mm) were tested to obtain their electrochemical and other technological properties. The coloring process was done using the potential of 15, 30, 45, 60, and 75 Volts for 5 s in 1 wt. % citric acid in demineralized water solution. Organic acids solutions generally produce better surface quality compared to inorganic acids. The contact angle of colored surfaces was measured by the sessile drop method. Electrochemical impedance spectroscopy and potentiodynamic polarization were used for the determination of selected electrochemical and corrosion parameters of the tested surfaces. It was found that the anodization process decreases corrosion potential significantly. It was also confirmed that a higher potential used for anodization results in higher polarization resistance but also a decrease in corrosion potential. The anodization process at 75 V produces surfaces with the lowest corrosion rate under 1 nm/year and the noblest corrosion potential. It was confirmed that the anodization process in citric acid does not affect titanium cytotoxicity.

3.
Expert Rev Med Devices ; 19(9): 721-731, 2022 Sep.
Article in English | MEDLINE | ID: mdl-36225151

ABSTRACT

INTRODUCTION: Equinus contracture is a serious disability and attention should be paid to proper and effective treatment. Most attention is given to neurologically impaired patients, but the incidence of equinus contracture is much higher, for example, in post-traumatic patients. In addition to conventional physical therapy, robotic rehabilitation treatment is one of the promising procedures to precede severe contraction cases and the need for surgery. AREAS COVERED: This study aims to cover the description of different types of stationary and wearable ankle rehabilitation devices suitable for the treatment of equinus contracture and point to deficiency in research, clinical trials, and launch of the market. EXPERT OPINION: This review provides insight into ankle rehabilitation devices with a focus on equinus contracture. Due to the fact that robotic devices successfully restore the condition of patients, attention should not be paid only to those with neurological impairments. This paper points that future research should be effectively linked to clinical practice with the aim of covering a wider range of disabilities and make an effort to successfully introduce devices from development into the practice.


Subject(s)
Equinus Deformity , Orthopedic Procedures , Humans , Equinus Deformity/etiology , Equinus Deformity/surgery , Ankle/surgery , Ankle Joint/surgery , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...