Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Database
Language
Publication year range
1.
J Appl Crystallogr ; 56(Pt 4): 1032-1037, 2023 Aug 01.
Article in English | MEDLINE | ID: mdl-37555222

ABSTRACT

The CITIUS detector is a next-generation high-speed X-ray imaging detector. It has integrating-type pixels and is designed to show a consistent linear response at a frame rate of 17.4 kHz, which results in a saturation count rate of over 30 Mcps pixel-1 when operating at an acquisition duty cycle close to 100%, and up to 20 times higher with special extended acquisition modes. Here, its application for Bragg coherent diffraction imaging is demonstrated by taking advantage of the fourth-generation Extremely Brilliant Source of the European Synchrotron (ESRF-EBS, Grenoble, France). The CITIUS detector outperformed a photon-counting detector, similar spatial resolution being achieved (20 ±â€…6 nm versus 22 ±â€…9 nm) with greatly reduced acquisition times (23 s versus 200 s). It is also shown how the CITIUS detector can be expected to perform during dynamic Bragg coherent diffraction imaging measurements. Finally, the current limitations of the CITIUS detector and further optimizations for coherent imaging techniques are discussed.

2.
J Synchrotron Radiat ; 29(Pt 6): 1394-1406, 2022 Nov 01.
Article in English | MEDLINE | ID: mdl-36345747

ABSTRACT

The new generation of synchrotron light sources are pushing X-ray detectors to their limits. Very demanding conditions with unprecedented flux and higher operating energies now require high-performance X-ray detectors combining sensitivity, efficiency and scalability. Over the years, hybrid pixel detectors have supplemented indirect detectors based on scintillation, with undeniable advantages. Such detectors based on silicon are, however, rather expensive to produce and are no more satisfying in terms of X-ray stopping power when targeting energies above 20 keV. An indirect detector with single X-ray photon sensitivity therefore offers promising opportunities for applications operating over a wide range of energies and fluxes. In this work, the performances of such an approach are investigated with state-of-the-art elements: a commercial sCMOS camera with fiber-optics plate coupling and a Gd2O2S:Tb powder-based scintillator. A simple method is presented for evaluation of the single X-ray photon detection limit and single X-ray sensitivity is demonstrated with the studied detector above 20 keV. Geant4 simulations also provide insight to better define the limiting factors. Finally, guidelines are provided for future R&D in the design and assembly of an innovative detector combining advantages of direct and indirect detection schemes.

3.
Opt Express ; 30(9): 14461-14477, 2022 Apr 25.
Article in English | MEDLINE | ID: mdl-35473188

ABSTRACT

A large and increasing number of scientific domains pushes for high neutron imaging resolution achieved in reasonable times. Here we present the principle, design and performance of a detector based on infinity corrected optics combined with a crystalline Gd3Ga5O12 : Eu scintillator, which provides an isotropic sub-4 µm true resolution. The exposure times are only of a few minutes per image. This is made possible also by the uniquely intense cold neutron flux available at the imaging beamline NeXT-Grenoble. These comparatively rapid acquisitions are compatible with multiple high quality tomographic acquisitions, opening new venues for in-operando testing, as briefly exemplified here.

4.
J Synchrotron Radiat ; 27(Pt 5): 1347-1357, 2020 Sep 01.
Article in English | MEDLINE | ID: mdl-32876610

ABSTRACT

Recent trends in hard X-ray micro-computed tomography (microCT) aim at increasing both spatial and temporal resolutions. These challenges require intense photon beams. Filtered synchrotron radiation beams, also referred to as `pink beams', which are emitted by wigglers or bending magnets, meet this need, owing to their broad energy range. In this work, the new microCT station installed at the biomedical beamline ID17 of the European Synchrotron is described and an overview of the preliminary results obtained for different biomedical-imaging applications is given. This new instrument expands the capabilities of the beamline towards sub-micrometre voxel size scale and simultaneous multi-resolution imaging. The current setup allows the acquisition of tomographic datasets more than one order of magnitude faster than with a monochromatic beam configuration.


Subject(s)
X-Ray Microtomography/instrumentation , Animals , Equipment Design , Europe , Humans , Imaging, Three-Dimensional , In Vitro Techniques , Lung/diagnostic imaging , Mice , Phantoms, Imaging , Spinal Cord/diagnostic imaging , Synchrotrons
5.
J Synchrotron Radiat ; 17(5): 571-83, 2010 Sep.
Article in English | MEDLINE | ID: mdl-20724778

ABSTRACT

The efficiency of high-resolution pixel detectors for hard X-rays is nowadays one of the major criteria which drives the feasibility of imaging experiments and in general the performance of an experimental station for synchrotron-based microtomography and radiography. Here the luminescent screen used for the indirect detection is focused on in order to increase the detective quantum efficiency: a novel scintillator based on doped Lu(2)SiO(5) (LSO), epitaxially grown as thin film via the liquid phase epitaxy technique. It is shown that, by using adapted growth and doping parameters as well as a dedicated substrate, the scintillation behaviour of a LSO-based thin crystal together with the high stopping power of the material allows for high-performance indirect X-ray detection. In detail, the conversion efficiency, the radioluminescence spectra, the optical absorption spectra under UV/visible-light and the afterglow are investigated. A set-up to study the effect of the thin-film scintillator's temperature on its conversion efficiency is described as well. It delivers knowledge which is important when working with higher photon flux densities and the corresponding high heat load on the material. Additionally, X-ray imaging systems based on different diffraction-limited visible-light optics and CCD cameras using among others LSO-based thin film are compared. Finally, the performance of the LSO thin film is illustrated by imaging a honey bee leg, demonstrating the value of efficient high-resolution computed tomography for life sciences.


Subject(s)
Bees/ultrastructure , Radiographic Image Enhancement/methods , X-Ray Intensifying Screens , Animals , Extremities/anatomy & histology , Lutetium , Silicates , Synchrotrons , X-Ray Microtomography/methods
SELECTION OF CITATIONS
SEARCH DETAIL
...