Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Type of study
Language
Publication year range
1.
J Cardiovasc Electrophysiol ; 35(5): 950-964, 2024 May.
Article in English | MEDLINE | ID: mdl-38477184

ABSTRACT

INTRODUCTION: Peak frequency (PF) mapping is a novel method that may identify critical portions of myocardial substrate supporting reentry. The aim of this study was to describe and evaluate PF mapping combined with omnipolar voltage mapping in the identification of critical isthmuses of left atrial (LA) atypical flutters. METHODS AND RESULTS: LA omnipolar voltage and PF maps were generated in flutter using the Advisor HD-Grid catheter (Abbott) and EnSite Precision Mapping System (Abbott) in 12 patients. Normal voltage was defined as ≥0.5 mV, low-voltage as 0.1-0.5 mV, and scar as <0.1 mV. PF distributions were compared with ANOVA and post hoc Tukey analyses. The 1 cm radius from arrhythmia termination was compared to global myocardium with unpaired t-testing. The mean age was 65.8 ± 9.7 years and 50% of patients were female. Overall, 34 312 points were analyzed. Atypical flutters most frequently involved the mitral isthmus (58%) or anterior wall (25%). Mean PF varied significantly by myocardial voltage: normal (335.5 ± 115.0 Hz), low (274.6 ± 144.0 Hz), and scar (71.6 ± 140.5 Hz) (p < .0001 for all pairwise comparisons). All termination sites resided in low-voltage regions containing intermediate or high PF. Overall, mean voltage in the 1 cm radius from termination was significantly lower than the remaining myocardium (0.58 vs. 0.95 mV, p < .0001) and PF was significantly higher (326.4 vs. 245.1 Hz, p < .0001). CONCLUSION: Low-voltage, high-PF areas may be critical targets during catheter ablation of atypical atrial flutter.


Subject(s)
Action Potentials , Atrial Flutter , Catheter Ablation , Electrophysiologic Techniques, Cardiac , Predictive Value of Tests , Humans , Atrial Flutter/physiopathology , Atrial Flutter/diagnosis , Atrial Flutter/surgery , Female , Male , Aged , Middle Aged , Heart Rate
2.
JACC Clin Electrophysiol ; 8(12): 1539-1552, 2022 12.
Article in English | MEDLINE | ID: mdl-36779625

ABSTRACT

BACKGROUND: Peak-to-peak bipolar voltage varies with electrode orientation, fractionation, and collision events. Novel, omnipolar mapping is less dependent on electrode orientation but has limited data in humans. OBJECTIVES: This study sought to compare bipolar peak-to-peak voltage with omnipolar maximum voltage (Vmax) during sinus rhythm in the left atrium of patients with persistent (PerAF) or paroxysmal atrial fibrillation (PAF). METHODS: Baseline voltage maps were generated with bipolar and omnipolar mapping in 20 patients undergoing de novo catheter ablation for PerAF or PAF and 9 patients with known scar from prior cardiac surgery, to validate voltage-based scar approximations. Low voltage was defined as <0.5 mV and scar <0.1 mV. Mean voltage was compared with unpaired t testing. Percent low voltage and scar were compared with chi-square testing. A point-to-point comparison was performed with Bland-Altman analysis. RESULTS: The mean age was 62.2 ± 9.9 years, 34% were women, and 41% had heart failure. Omnipolar mapping identified significantly higher mean voltage than bipolar mapping and classified less points as low voltage (PerAF: 32.90% vs 43.40%; PAF: 19.20% vs 25.60%) and scar (PerAF: 7.72% vs 12.10%; PAF: 4.03% vs 6.07%) (all P < 0.0001). Omnipolar Vmax displayed significant disagreement with bipolar by Bland-Altman analysis. Scar and low-voltage approximations were validated in atria with known scar, in which bipolar mapping overestimated the extent of low voltage (P < 0.0001) and scar (P < 0.0001). CONCLUSIONS: Omnipolar mapping identifies higher voltage and has greater specificity for the detection of low voltage and scar than conventional bipolar mapping in patients with PerAF or PAF.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Humans , Female , Middle Aged , Aged , Male , Cicatrix/etiology , Heart Atria , Heart Rate , Catheter Ablation/adverse effects
SELECTION OF CITATIONS
SEARCH DETAIL
...