1.
Int J Radiat Oncol Biol Phys ; 50(5): 1265-78, 2001 Aug 01.
Article in English | MEDLINE | ID: mdl-11483338

ABSTRACT

BACKGROUND: Stereotactic radiosurgery (SRS) and, more recently, fractionated stereotactic radiotherapy (SRT) have been recognized as noninvasive alternatives to surgery for the treatment of acoustic schwannomas. We review our experience of acoustic tumor treatments at one institution using a gamma knife for SRS and the first commercial world installation of a dedicated linac for SRT. METHODS: Patients were treated with SRS on the gamma knife or SRT on the linac from October 1994 through August 2000. Gamma knife technique involved a fixed-frame multiple shot/high conformality single treatment, whereas linac technique involved daily conventional fraction treatments involving a relocatable frame, fewer isocenters, and high conformality established by noncoplanar arc beam shaping and differential beam weighting. RESULTS: Sixty-nine patients were treated on the gamma knife, and 56 patients were treated on the linac, with 1 NF-2 patient common to both units. Three patients were lost to follow-up, and in the remaining 122 patients, mean follow-up was 119 +/- 67 weeks for SRS patients and 115 +/- 96 weeks for SRT patients. Tumor control rates were high (> or =97%) for sporadic tumors in both groups but lower for NF-2 tumors in the SRT group. Cranial nerve morbidities were comparably low in both groups, with the exception of functional hearing preservation, which was 2.5-fold higher in patients who received conventional fraction SRT. CONCLUSION: SRS and SRT represent comparable noninvasive treatments for acoustic schwannomas in both sporadic and NF-2 patient groups. At 1-year follow-up, a significantly higher rate of serviceable hearing preservation was achieved in SRT sporadic tumor patients and may therefore be preferable to alternatives including surgery, SRS, or possibly observation in patients with serviceable hearing.


Subject(s)
Dose Fractionation, Radiation , Neuroma, Acoustic/surgery , Radiosurgery/methods , Adult , Cochlear Nerve/radiation effects , Facial Nerve/radiation effects , Female , Follow-Up Studies , Gait/radiation effects , Hearing Loss, Sensorineural/epidemiology , Hearing Loss, Sensorineural/etiology , Humans , Magnetic Resonance Imaging , Male , Middle Aged , Neurofibromatosis 2/complications , Neurofibromatosis 2/pathology , Neurofibromatosis 2/surgery , Neuroma, Acoustic/complications , Neuroma, Acoustic/pathology , Particle Accelerators , Philadelphia/epidemiology , Radiation Injuries/epidemiology , Radiation Injuries/etiology , Radiosurgery/adverse effects , Radiosurgery/instrumentation , Retrospective Studies , Treatment Outcome , Vertigo/epidemiology , Vertigo/etiology
2.
Neurosurgery ; 45(5): 1156-61; discussion 1161-3, 1999 Nov.
Article in English | MEDLINE | ID: mdl-10549932

ABSTRACT

PURPOSE: This study was undertaken to determine the impact of geometric distortions on the spatial accuracy of magnetic resonance imaging (MRI)-guided stereotactic localization for gamma knife functional radiosurgery. METHOD: The spatial accuracy of MRI was evaluated by comparing stereotactic coordinates of intracranial targets, external fiducials, and anatomic structures defined by computed tomographic and MRI studies of the Radionics skull phantom (Radionics, Inc., Burlington, MA), the Rando head phantom, and 11 patients who underwent gamma knife functional radiosurgery. The distortion in MRI was assessed from computed tomographic and MRI fusion studies for these patients, as well as from MRI studies acquired by swapping the direction of the magnetic field gradients for five patients who underwent gamma knife radiosurgery and three patients who underwent MRI-guided frameless surgery. A follow-up program to compare the location of the created lesion with the intended target complemented the analysis. RESULTS: The average difference between computed tomographic and MRI stereotactic coordinates of external fiducials, intracranial targets, and anatomic landmarks was of the order of 1 pixel size (0.9 x 0.9 x 1 mm3) along the x, y, and z axes. The average linear scaling along these axes as determined by fusion studies was approximately 0.8% and consistent with a single pixel. The follow-up studies, available for seven patients, revealed good agreement between the location of the created lesion and the intended target. CONCLUSION: The spatial accuracy of an MRI-based localization system can be comparable to computed tomography-based localization with the added benefit of MRI resolution. Both machine- and object-related MRI distortions can be reduced to an acceptable level with contemporary scanners, optimized scanning sequences, and distortion-resistant stereotactic instruments.


Subject(s)
Brain Diseases/surgery , Magnetic Resonance Imaging , Radiosurgery , Stereotaxic Techniques , Artifacts , Humans , Parkinson Disease/surgery , Phantoms, Imaging , Quality Assurance, Health Care , Sensitivity and Specificity , Treatment Outcome , Tremor/surgery , Trigeminal Neuralgia/surgery
3.
Radiother Oncol ; 38(1): 61-8, 1996 Jan.
Article in English | MEDLINE | ID: mdl-8850427

ABSTRACT

A stereotactic radiosurgery and radiotherapy (SRS/SRT) system on a dedicated Varian Clinac-600SR linear accelerator with Brown-Roberts-Wells and Gill-Thomas-Cosman relocatable frames along with the Radionics (RSA) planning system is evaluated. The Clinac-600SR has a single 6-MV beam with the same beam characteristics as that of the mother unit, the Clinac-600C. The primary collimator is a fixed cone projecting to a 10-cm diameter at isocenter. The secondary collimator is a heavily shielded cylindrical collimator attached to the face plate of the primary collimator. The tertiary collimation consists of the actual treatment cones. The cone sizes vary from 12.5 to 40.0 mm diameter. The mechanical stability of the entire system was verified. The variations in isocenter position with table, gantry, and collimator rotation were found to be < 0.5 mm with a compounded accuracy of < or = 1.0 mm. The radiation leakage under the cones was < 1% measured at a depth of 5 cm in a phantom. The beam profiles of all cones in the x and y directions were within +/- 0.5 mm and match with the physical size of the cone. The dosimetric data such as tissue maximum ratio, off-axis ratio, and cone factor were taken using film, diamond detector, and ion chambers. The mechanical and dosimetric characteristics including dose linearity of this unit are presented and found to be suitable for SRS/SRT. The difficulty in absolute dose measurement for small cone is discussed.


Subject(s)
Particle Accelerators , Radiosurgery/instrumentation , Radiotherapy/instrumentation , Equipment Design , Equipment Safety , Film Dosimetry , Health Physics , Humans , Phantoms, Imaging , Radiation Protection/instrumentation , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted , Radiotherapy, High-Energy/instrumentation , Surface Properties