Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Sci Rep ; 10(1): 7480, 2020 05 04.
Article in English | MEDLINE | ID: mdl-32366912

ABSTRACT

Temperature-resolved magnetic particle imaging (MPI) represents a promising tool for medical imaging applications. In this study an approach based on a single calibration measurement was applied for highlighting the potential of MPI for monitoring of temperatures during thermal ablation of liver tumors. For this purpose, liver tissue and liver tumor phantoms embedding different superparamagnetic iron oxide nanoparticles (SPION) were prepared, locally heated up to 70 °C and recorded with MPI. Optimal temperature MPI SPIONs and a corresponding linear model for temperature calculation were determined. The temporal and spatial temperature distributions were compared with infrared (IR) camera results yielding quantitative agreements with a mean absolute deviation of 1 °C despite mismatches in boundary areas.


Subject(s)
Hyperthermia, Induced , Infrared Rays , Liver Neoplasms , Magnetite Nanoparticles , Tomography, Optical , Animals , Chickens , Liver , Liver Neoplasms/diagnostic imaging , Liver Neoplasms/therapy
2.
Rev Sci Instrum ; 90(2): 024101, 2019 Feb.
Article in English | MEDLINE | ID: mdl-30831678

ABSTRACT

Superparamagnetic iron oxide nanoparticles (SPIONs) are used as a tracer material in sentinel node biopsies. The latter is a procedure to analyze if cancer cells have spread to lymph nodes, helping to personalize patient care. To predict SPION behavior in vivo, it is important to analyze their magnetic properties in biological environments. The superparamagnetic quantifier (SPaQ) is a new device to measure the dynamic magnetization curve of SPIONs. The magnetization curve was measured for two types of SPIONs: Resovist and SHP-25. We used three techniques: Vibrating Sample Magnetometry (VSM), Magnetic Particle Spectroscopy (MPS), and our new SPaQ. Furthermore, AC susceptibility (ACS) measurements were performed as part of the evaluation of the three techniques. SPaQ and VSM results were found to be similar. Measurement results were nearly identical in both directions, indicating minor hysteresis. However, in MPS measurements, a clear hysteresis loop was observed. Furthermore, the ACS measurements showed a pronounced Brownian maximum, indicating an optimal response for an AC frequency below 10 kHz for both particle systems. Both the SPaQ and MPS were found to be superior to VSM since measurements are faster, can be performed at room temperature, and are particularly sensitive to particle dynamics. The main difference between the SPaQ and MPS lies in the excitation sequence. The SPaQ combines an alternating magnetic field that has a low amplitude with a gradual DC offset, whereas MPS uses only an alternating field that has a large amplitude. In conclusion, both the SPaQ and MPS are highly suited to improve understanding SPION behavior, which will lead to the radical improvement of sentinel node biopsy accuracy.

SELECTION OF CITATIONS
SEARCH DETAIL
...