1.
J Diabetes Sci Technol ; : 19322968221141924, 2022 Dec 08.
Article in English | MEDLINE | ID: mdl-36475908

ABSTRACT

OBJECTIVE: Many hybrid closed-loop (HCL) systems struggle to manage unusually high glucose levels as experienced with intercurrent illness or pre-menstrually. Manual correction boluses may be needed, increasing hypoglycemia risk with overcorrection. The Cambridge HCL system includes a user-initiated algorithm intensification mode ("Boost"), activation of which increases automated insulin delivery by approximately 35%, while remaining glucose-responsive. In this analysis, we assessed the safety of "Boost" mode. METHODS: We retrospectively analyzed data from closed-loop studies involving young children (1-7 years, n = 24), children and adolescents (10-17 years, n = 19), adults (≥24 years, n = 13), and older adults (≥60 years, n = 20) with type 1 diabetes. Outcomes were calculated per participant for days with ≥30 minutes of "Boost" use versus days with no "Boost" use. Participants with <10 "Boost" days were excluded. The main outcome was time spent in hypoglycemia <70 and <54 mg/dL. RESULTS: Eight weeks of data for 76 participants were analyzed. There was no difference in time spent <70 and <54 mg/dL between "Boost" days and "non-Boost" days; mean difference: -0.10% (95% confidence interval [CI] -0.28 to 0.07; P = .249) time <70 mg/dL, and 0.03 (-0.04 to 0.09; P = .416) time < 54 mg/dL. Time in significant hyperglycemia >300 mg/dL was 1.39 percentage points (1.01 to 1.77; P < .001) higher on "Boost" days, with higher mean glucose and lower time in target range (P < .001). CONCLUSIONS: Use of an algorithm intensification mode in HCL therapy is safe across all age groups with type 1 diabetes. The higher time in hyperglycemia observed on "Boost" days suggests that users are more likely to use algorithm intensification on days with extreme hyperglycemic excursions.

2.
Lancet Healthy Longev ; 3(3): e135-e142, 2022 03.
Article in English | MEDLINE | ID: mdl-35359882

ABSTRACT

Background: Older adults with type 1 diabetes have distinct characteristics that can make optimising glycaemic control challenging. We sought to test our hypothesis that hybrid closed-loop glucose control is safe and more effective than sensor-augmented pump (SAP) therapy in older adults with type 1 diabetes. Methods: In an open-label, multicentre, multinational (UK and Austria), randomised, crossover study, adults aged 60 years and older with type 1 diabetes using insulin pump therapy underwent two 16-week periods comparing hybrid closed-loop (CamAPS FX, CamDiab, Cambridge, UK) and SAP therapy in random order. Block randomisation by means of central randomisation software to one of two treatment sequences was stratified by centre. The primary endpoint was the proportion of time sensor glucose was in target range between 3·9 and 10·0 mmol/L. Analysis for the primary endpoint and adverse events was by intention-to-treat. The study has completed and is registered at ClinicalTrials.gov NCT04025762. Findings: 38 participants were enrolled. One participant withdrew during run-in because of difficulties with the study pump infusion sets. 37 participants (median [IQR] age 68 [63-70] years, mean [SD] baseline glycated haemoglobin [HbA1c]; 7·4% [0·9%]; 57 [10] mmol/mol) were randomly assigned between Sept 4, 2019, and Oct 2, 2020. The proportion of time with glucose between 3·9 and 10·0 mmol/L was significantly higher in the closed-loop group compared to the SAP group (79·9% [SD 7·9] vs 71·4% [13·2], difference 8·6 percentage points [95% CI 6·3 to 11·0]; p<0·0001). Two severe hypoglycaemia events occurred during the SAP period. There were two non-treatment related serious adverse events: cardiac arrest from pulmonary embolism associated with COVID-19 during the SAP period resulting in death, and a hospital presentation for parenteral hydrocortisone because of COVID-19 in a participant with adrenal insufficiency during the run-in period. Interpretation: Hybrid closed-loop insulin delivery is safe and achieves superior glycaemic control to SAP therapy in older adults with long duration of type 1 diabetes. Importantly this was achieved without increasing the risk of hypoglycaemia in this population with risk factors for severe hypoglycaemia. This suggests that hybrid closed-loop therapy is a clinically important treatment option for older adults with type 1 diabetes.


Subject(s)
COVID-19 , Diabetes Mellitus, Type 1 , Hypoglycemia , Aged , Blood Glucose , Cross-Over Studies , Glucose , Humans , Hypoglycemic Agents , Insulin , Insulin Infusion Systems , Middle Aged , Treatment Outcome