Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Foot (Edinb) ; 43: 101663, 2020 Jun.
Article in English | MEDLINE | ID: mdl-32120284

ABSTRACT

Ossification of the Achilles tendon is a relatively common finding. However, a large ossification covering more than two third of the tendon is rarely seen. A 70 year old patient with a 12 cm long Achilles tendon ossification is discussed. The ossification was surgically removed and the tendon was subsequently reconstructed using a fascia lata autograft. Postoperatively the ankle was immobilised for 3 months. One year postoperatively the patient was completely recovered with the ability to stand on his toes, and minimal loss in range of motion. LEVEL OF CLINICAL EVIDENCE: 4.


Subject(s)
Achilles Tendon/pathology , Fascia Lata/transplantation , Ossification, Heterotopic/surgery , Plastic Surgery Procedures/methods , Achilles Tendon/surgery , Aged , Humans , Male , Ossification, Heterotopic/diagnosis , Ossification, Heterotopic/etiology
2.
J Mater Sci Mater Med ; 9(8): 449-55, 1998 Aug.
Article in English | MEDLINE | ID: mdl-15348857

ABSTRACT

The biocompatible, osteoconductive and resorbable polymer Polyactive (PA) was investigated for its performance as a bone-graft substitute. The model consisted of a 4 mm borehole, 1.5 cm distal of the major trochanter in both femurs of a rabbit, of which one was filled with a cylinder of porous PA. The other was left untreated. PA70/30 and PA60/40 were investigated, both before and after being incubated with allogenic bone marrow. Analyses were performed after 4, 8, 26 and 52 weeks and comprised dual energy X-ray absorptiometry (DXA) and image analysis of histological sections. DXA revealed an increased bone mineral density in the filled defects compared to the controls, both at the defect and immediately proximal and distal of the defect. Histology showed that gap-bridging had occurred within 8 weeks, with 80%-90% of the pores of PA70/30 and PA60/40 occupied by new bone, and an intimate bone-PA contact. PA70/30 seemed to be more suitable compared to PA60/40, in that the highest amount of bone was formed within the shortest period of time. Incubation of PA with allogenic bone marrow resulted in inflammatory reactions at the sites of implantation, which delayed bone growth, but did not prevent it. It was concluded that PA70/30 and PA60/40 are suitable bone-graft substitutes.

3.
J Mater Sci Mater Med ; 9(4): 181-5, 1998 Apr.
Article in English | MEDLINE | ID: mdl-15348889

ABSTRACT

The quantity of bone formed in cylinders of a newly developed erodible copolymer, Polyactive (PA60/40) was examined. PA60/40 was implanted in three different bone locations in the rabbit: in the cortex, in bone marrow and in trabecular subchondral bone. Bony ingrowth was assessed after 4, 8, 26 and 52 w after the operation and investigated by histology and image analysis. The ingrowth of bone was observed in PA60/40 placed in the cortex from 4 w onwards. After 8 w, more than 90% of the pores of the biomaterial were filled with dense bone. In bone marrow, initially some bone formation was seen. After 26 w, all newly formed bone was resorbed. Subchondral bone formation was less than in the cortex of the femur, but somewhat comparable to the amount of bone found in healthy trabecular bone. Bone formation appeared not to be affected by the degradation of the biomaterial. It was concluded that Polyactive is a suitable bone graft substitute. Bone formation within PA60/40 is site-dependent and this follows Wolff 's law.

SELECTION OF CITATIONS
SEARCH DETAIL
...