Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Rev Sci Instrum ; 89(10): 10E116, 2018 Oct.
Article in English | MEDLINE | ID: mdl-30399980

ABSTRACT

Wendelstein 7-X aims at quasi-steady state operation with up to 10 MW of heating power for 30 min. Power exhaust will be handled predominantly via 10 actively water cooled CFC (carbon-fiber-reinforced carbon) based divertor units designed to withstand power loads of 10 MW/m2 locally in steady state. If local loads exceed this value, a risk of local delamination of the CFC and failure of entire divertor modules arises. Infrared endoscopes to monitor all main plasma facing components are being prepared, and near real time software tools are under development to identify areas of excessive temperature rise, to distinguish them from non-critical events, and to trigger alarms. Tests with different cameras were made in the recent campaign. Long pulse operation enforces additional diagnostic design constraints: for example, the optics need to be thermally decoupled from the endoscope housing. In the upcoming experimental campaign, a graphite scraper element, in front of the island divertor throat, will be tested as a possible means to protect the divertor pumping gap edges during the transient discharge evolution.

2.
Rev Sci Instrum ; 87(11): 11E721, 2016 Nov.
Article in English | MEDLINE | ID: mdl-27910527

ABSTRACT

A new resistive bolometer system has been developed for MAST-Upgrade. It will measure radiated power in the new Super-X divertor, with millisecond time resolution, along 16 vertical and 16 horizontal lines of sight. The system uses a Xilinx Zynq-7000 series Field-Programmable Gate Array (FPGA) in the D-TACQ ACQ2106 carrier to perform real time data acquisition and signal processing. The FPGA enables AC-synchronous detection using high performance digital filtering to achieve a high signal-to-noise ratio and will be able to output processed data in real time with millisecond latency. The system has been installed on 8 previously unused channels of the JET vertical bolometer system. Initial results suggest good agreement with data from existing vertical channels but with higher bandwidth and signal-to-noise ratio.

3.
Rev Sci Instrum ; 80(12): 123501, 2009 Dec.
Article in English | MEDLINE | ID: mdl-20059139

ABSTRACT

The magnetic confinement of plasmas in fusion experiments can significantly degrade due to perturbations of the magnetic field. A precise analysis of the magnetic field in a stellarator-type experiment utilizes electrons as test particles following the magnetic field line. The usual fluorescent detector for this electron beam limits the provided information to two-dimensional cut views at certain toroidal positions. However, the technique described in this article allows measuring the three-dimensional structure of the magnetic field by means of close-range photogrammetry. After testing and optimizing the main diagnostic components, measurements of the magnetic field lines were accomplished with a spatial resolution of 5 mm. The results agree with numeric calculations, qualifying this technique as an additional tool to investigate magnetic field configurations in a stellarator. For a possible future application, ways are indicated on how to reduce experimental error sources.

SELECTION OF CITATIONS
SEARCH DETAIL
...