Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 26
Filter
1.
Int J Cardiol ; 167(6): 2539-45, 2013 Sep 10.
Article in English | MEDLINE | ID: mdl-22738784

ABSTRACT

BACKGROUND: Marfan syndrome (MFS) is a variable, autosomal-dominant disorder of the connective tissue. In MFS serious ventricular arrhythmias and sudden cardiac death (SCD) can occur. The aim of this prospective study was to reveal underlying risk factors and to prospectively investigate the association between MFS and SCD in a long-term follow-up. METHODS: 77 patients with MFS were included. At baseline serum N-terminal pro-brain natriuretic peptide (NT-proBNP), transthoracic echocardiogram, 12-lead resting ECG, signal-averaged ECG (SAECG) and a 24-h Holter ECG with time- and frequency domain analyses were performed. The primary composite endpoint was defined as SCD, ventricular tachycardia (VT), ventricular fibrillation (VF) or arrhythmogenic syncope. RESULTS: The median follow-up (FU) time was 868 days. Among all risk stratification parameters, NT-proBNP remained the exclusive predictor (hazard ratio [HR]: 2.34, 95% confidence interval [CI]: 1.1 to 4.62, p=0.01) for the composite endpoint. With an optimal cut-off point at 214.3 pg/ml NT-proBNP predicted the composite primary endpoint accurately (AUC 0.936, p=0.00046, sensitivity 100%, specificity 79.0%). During FU, seven patients of Group 2 (NT-proBNP ≥ 214.3 pg/ml) reached the composite endpoint and 2 of these patients died due to SCD. In five patients, sustained VT was documented. All patients with a NT-proBNP<214.3 pg/ml (Group 1) experienced no events. Group 2 patients had a significantly higher risk of experiencing the composite endpoint (logrank-test, p<0.001). CONCLUSIONS: In contrast to non-invasive electrocardiographic parameter, NT-proBNP independently predicts adverse arrhythmogenic events in patients with MFS.


Subject(s)
Death, Sudden, Cardiac/epidemiology , Marfan Syndrome/diagnostic imaging , Marfan Syndrome/mortality , Adult , Female , Follow-Up Studies , Humans , Male , Marfan Syndrome/physiopathology , Middle Aged , Prospective Studies , Risk Assessment , Ultrasonography , Young Adult
2.
Eur Radiol ; 22(9): 1904-11, 2012 Sep.
Article in English | MEDLINE | ID: mdl-22538633

ABSTRACT

OBJECTIVES: There is currently no agreement on the best method of assessing active left atrial (LA) emptying. This study evaluated the relative merits of cine- and velocity encoded (VENC) magnetic resonance imaging (MRI) for the assessment of active LA emptying. METHODS: Total LA emptying volume (TLAEV) and active LA stroke volume (ALASV) were assessed in 107 consecutive patients using cine-MRI and transmitral flow measurements by VENC-MRI. The fraction of active LA emptying (ALAEF) was calculated as the ratio of ALASV to TLAEV. LA and left ventricular (LV) output were calculated by multiplying TLAEV and LV stroke volume by heart rate, respectively. RESULTS: Intra- and inter-observer variances were significantly larger for cine-MRI than for VENC-MRI measurements of ALASV (24.7 mL(2) vs. 3.7 mL(2) and 57.7 mL(2) vs. 4.2 mL(2); P < 0.0001). Biplane cine-MRI underestimated TLAEV (mean difference -57 ± 32 %; P < 0.0001) and ALASV (mean difference -24 ± 51 %; P < 0.0001) but overestimated ALAEF (mean difference 31 ± 54 %, P < 0.0001) compared with VENC-MRI. There was significantly better agreement between LV output and LA output measured by VENC-MRI compared with LA output measured by cine-MRI (mean difference 0.30 ± 1.12 L/min vs. -2.05 ± 1.44 L/min; P < 0.0001). CONCLUSION: VENC-MRI is the more appropriate method of assessing active LA emptying and its use should be favoured.


Subject(s)
Algorithms , Atrial Function, Left , Heart Atria/pathology , Heart Atria/physiopathology , Image Interpretation, Computer-Assisted/methods , Magnetic Resonance Imaging, Cine/methods , Aged , Female , Humans , Image Enhancement/methods , Male , Middle Aged , Reproducibility of Results , Sensitivity and Specificity
3.
J Cardiovasc Electrophysiol ; 23(1): 54-9, 2012 Jan.
Article in English | MEDLINE | ID: mdl-21815963

ABSTRACT

BACKGROUND: External biphasic electrical cardioversion (CV) is a standard treatment option for patients suffering from acute symptoms of atrial fibrillation (AF). Nevertheless, CV is not always successful, and thus strategies to increase the success rate are desirable. OBJECTIVE: The purpose of this study was to evaluate the effect of intravenously administered K/Mg solution on the biphasic CV energy threshold and success rate to restore sinus rhythm (SR) in patients with AF. METHODS: The study consisted of 170 patients with persistent AF. The patients were randomly assigned to undergo biphasic CV either with (n = 84) or without (n = 86) pretreatment with K/Mg solution. An energy step-up protocol of 75, 100, and 150 W (J) was used. RESULTS: Biphasic CV of AF was effective in 81 (96.4%) patients in the pretreatment and 74 (86.0%) patients in the control group (P = 0.005). The effective energy level required to achieve SR was significantly lower in the pretreated group (140.8 ± 26.9 J vs 182.5 ± 52.2 J, P = 0.02). No K/Mg-solution-associated side effects such as hypotension or bradycardia were observed. CONCLUSION: Administration of K/Mg solution positively influences the success rate of CV in patients with persistent AF. Furthermore, significantly less energy is required to successfully restore SR and therefore K/Mg pretreatment may facilitate SR restoration in patients undergoing CV for AF.


Subject(s)
Atrial Fibrillation/therapy , Defibrillators , Electric Countershock/instrumentation , Magnesium/administration & dosage , Potassium/administration & dosage , Aged , Atrial Fibrillation/diagnosis , Atrial Fibrillation/physiopathology , Combined Modality Therapy , Electric Countershock/adverse effects , Female , Germany , Humans , Infusions, Intravenous , Magnesium/adverse effects , Male , Middle Aged , Potassium/adverse effects , Treatment Outcome
4.
Europace ; 14(3): 325-30, 2012 Mar.
Article in English | MEDLINE | ID: mdl-22024600

ABSTRACT

AIMS: Patients can expect a cure from atrial fibrillation (AF) with ablation. Procedural safety and success depend on patient comfort, compliance, and immobility. This is difficult to achieve with benzodiazepine and opiate boluses that are the mainstay of current practice. We sought to determine the safety and efficacy of propofol infusion sedation administered to patients without assisted ventilation for AF ablation. METHODS AND RESULTS: Procedural data from 1000 consecutive patients undergoing AF ablation were analysed. Sedation with 2% propofol was used in all procedures without assisted ventilation and was administered, monitored, and controlled by electrophysiologists. Primary outcome measures were adverse sedative affects including (i) respiratory depression (SpO(2)< 90% for >20 s) and (ii) persistent hypotension [systolic blood pressure (SBP)<90 mmHg at minimum sedation level]. Secondary endpoints included full recovery within 60 min and procedural complications. Of 1000 ablations, 506 ablations were performed for persistent and 494 for paroxysmal AF. Average patient age was 60.1 ± 11.3 years (72.3% male). Propofol was commenced in all patients at a mean infusion rate of 18.5 ± 4.8 mL/h with a mean baseline SBP of 140.3 ± 19.9 mmHg. Mean procedure time was 148.7 ± 57.7 min. Adverse sedative effects necessitating cessation of propofol and switch to midazolam bolus sedation occurred in 15.6% of patients (13.6% due to persistent hypotension, 1.9% due to respiratory depression, and 0.1% due to hypersalivation). Patients who had persistent hypotension were older (62.9 ± 11.2 vs. 60.0 ± 11.4 years, P= 0.011) and more likely to be female (39.5 vs. 23.7%, P< 0.001) than those who tolerated propofol. Patient age correlated to maximum blood pressure drop with propofol (R(2)= 0.101, P< 0.001) and inversely correlated to mean propofol infusion rate (R(2)= 0.066, P< 0.001). No procedures were abandoned due to adverse effects of sedation. All patients recovered within 60 min. Serious procedural complications, unrelated to sedation, occurred in 0.5%, all of whom had pericardial tamponade successfully treated with percutaneous pericardiocentesis. CONCLUSIONS: Sedation with 2% propofol infusion administered by cardiologists without assisted ventilation is safe, effective, and practical for use in AF ablation without serious or residual complications. In this setting, persistent hypotension is the most common acute adverse effect requiring cessation of propofol in ∼14%.


Subject(s)
Anesthetics, Intravenous/therapeutic use , Atrial Fibrillation/surgery , Catheter Ablation/methods , Deep Sedation/methods , Propofol/therapeutic use , Aged , Anesthetics, Intravenous/adverse effects , Cardiac Tamponade/surgery , Cohort Studies , Female , Humans , Hypotension/chemically induced , Male , Midazolam/therapeutic use , Middle Aged , Pericardiocentesis , Propofol/adverse effects , Respiratory Insufficiency/chemically induced , Sialorrhea/chemically induced , Treatment Outcome
5.
Europace ; 14(3): 410-5, 2012 Mar.
Article in English | MEDLINE | ID: mdl-22048993

ABSTRACT

AIMS: The aim of this study was to assess the role of a non-pharmacological approach on the frequency of traumatic injuries and syncope recurrence in patients with vasovagal syncope and normal hearts. We report the experience in our syncope centre with a standardized education and teaching protocol for patients with vasovagal syncope. The treatment of vasovagal syncope is often complex and discouraging. Besides medical options, behaviour modification is a main component of therapy but has no statistical evidence to support its use. METHODS AND RESULTS: Between January 1999 and September 2006, we prospectively enrolled all patients with vasovagal syncope. The patients were counselled about the benign nature of their disease. Specific recommendations were made according to a standardized education protocol established at our syncope centre. A pre-/post-study was conducted to investigate the effectiveness of our approach on syncope recurrence and frequency of injury as the study endpoints. Complete follow-up data were available from 85% of the study population (316 of 371) after a mean time of 710 ± 286 days (mean age 50 years; standard deviation ± 18 years, 160 female). Eighty-seven patients (27.5%) had a syncope recurrence with 22 suffering an injury during syncope. During the follow-up period, the syncope burden per month was significantly reduced from 0.35 ± 0.03 at initial presentation to 0.08 ± 0.02 (P< 0.001). The frequency of traumatic syncope was significantly lower at the time of recurrence compared with the initial presentation (25 vs. 42%; McNemar's test P= 0.02). CONCLUSION: A standardized education protocol significantly reduces traumatic injuries and syncope recurrence in patients with vasovagal syncope.


Subject(s)
Health Knowledge, Attitudes, Practice , Syncope, Vasovagal/prevention & control , Wounds and Injuries/prevention & control , Adult , Aged , Female , Humans , Male , Middle Aged , Syncope, Vasovagal/complications , Treatment Outcome , Wounds and Injuries/etiology
6.
Heart Rhythm ; 8(9): 1391-7, 2011 Sep.
Article in English | MEDLINE | ID: mdl-21699825

ABSTRACT

BACKGROUND: Stepwise ablation is an effective treatment for persistent atrial fibrillation (AF), although it often requires multiple procedures to eliminate recurrent arrhythmias. OBJECTIVE: This study evaluated single- and multiple-procedure long-term success rates and potential predictors of a favorable single-procedure outcome of stepwise ablation for persistent AF. METHODS: This study comprised 395 patients with persistent AF (duration 16 months) undergoing de novo catheter ablation using the stepwise approach. Procedural success was defined as the absence of any arrhythmia recurrence. Patient characteristics and electrophysiological parameters were analyzed with respect to single- and multiple-procedure outcomes. RESULTS: After a follow-up of 27 ± 7 months, 108 (27%) patients were free of arrhythmia recurrences with a single procedure. After 2.3 ± 0.6 procedures, 312 (79%) patients were free of arrhythmia with concomitant antiarrhythmic treatment in 38% (23% on ß-blocker). Female gender, duration of persistent AF, and congestive heart failure were predictive for the outcome after first ablation. However, the strongest predictors for single-procedure success were longer baseline AF cycle length (CL) and procedural AF termination. Moreover, procedural AF termination during the index procedure also predicted a favorable outcome after the last procedure, while the existence of congestive heart failure was associated with an increased risk for eventual arrhythmia recurrences. CONCLUSIONS: Single-procedure long-term success is anticipated in approximately a quarter of patients undergoing de novo ablation of persistent AF. Baseline AFCL emerged as the strongest predictor of single-procedure success, while AF termination during index ablation predicts the overall outcome. However, an overall success rate of 79% is achievable with multiple procedures.


Subject(s)
Atrial Fibrillation/physiopathology , Atrial Fibrillation/surgery , Catheter Ablation/methods , Heart Atria/physiopathology , Heart Conduction System/physiopathology , Atrial Fibrillation/mortality , Decision Trees , Electrocardiography , Electrophysiologic Techniques, Cardiac , Female , Follow-Up Studies , Germany , Humans , Male , Middle Aged , Recurrence , Retrospective Studies , Treatment Outcome
7.
Clin Res Cardiol Suppl ; 6: 73-7, 2011 May.
Article in German | MEDLINE | ID: mdl-22528181

ABSTRACT

Catheter ablation of atrial fibrillation has evolved as a widely accepted therapy approach and is now also incorporated in the current guidelines.A major limitation consists of the limited three-dimensional visualization of the complex three-dimensional structures in the left atrium since most procedures have routinely been performed using fluoroscopy alone. Another unsolved problem is the limited durability of lesions sets performed with radiofrequency ablation and therefore somewhat disappointing long-term ablation results besides fluoroscopy exposition for patient and operator as required for safe catheter manipulation.In the recent years we have gained substantial insight with respect to arrhythmia mechanism. At the same time new techniques and developments have become available to improve catheter ablation results.The present article summarizes the available opportunities with respect to three-dimensional mapping including CT/MRI image integration and gives an overview of the robotic and magnetic systems available for catheter ablation.


Subject(s)
Atrial Fibrillation/surgery , Catheter Ablation/methods , Imaging, Three-Dimensional , Magnetic Resonance Imaging, Interventional , Radiography, Interventional/methods , Robotics , Surgery, Computer-Assisted , Tomography, X-Ray Computed , Atrial Fibrillation/diagnostic imaging , Atrial Fibrillation/pathology , Catheter Ablation/adverse effects , Catheter Ablation/instrumentation , Equipment Design , Humans , Imaging, Three-Dimensional/instrumentation , Magnetic Resonance Imaging, Interventional/instrumentation , Magnetics , Radiographic Image Interpretation, Computer-Assisted , Radiography, Interventional/instrumentation , Robotics/instrumentation , Surgery, Computer-Assisted/adverse effects , Surgery, Computer-Assisted/instrumentation , Tomography, X-Ray Computed/instrumentation , Treatment Outcome
8.
Circ Arrhythm Electrophysiol ; 3(4): 351-60, 2010 Aug.
Article in English | MEDLINE | ID: mdl-20511536

ABSTRACT

BACKGROUND: Termination of persistent atrial fibrillation (AF) can be achieved through ablation, with the majority of patients terminating to an atrial tachycardia (AT) and fewer directly to sinus rhythm (SR). We aimed to identify potential predictors for the existence of a substrate for AT on termination to SR. METHODS AND RESULTS: We assessed 95 persistent AF patients (age, 60+/-10 years) who underwent catheter ablation to the end point of AF termination. Forty patients terminated directly to SR (SRterm) and 55 to ATs (ATterm). Compared with the ATterm group, the SRterm group were younger (56+/-10 versus 63+/-9 years, P=0.001), had shorter durations of AF before ablation (9+/-26 versus 14+/-20 months, P<0.001), smaller left atrial diameters (41+/-5 versus 45+/-5 mm, P=0.015), and longer baseline AF cycle lengths (178+/-23 versus 159+/-31 ms, P=0.005). However, AF cycle length was the sole independent predictor of direct termination to SR. The most frequent AF termination site in SRterm patients was the pulmonary veins (53%), whereas in ATterm patients this was within the left atrium (58%). After follow-up of 12+/-6 months, there was a trend toward a greater proportion of patients in SR among those who terminated directly to SR after a single procedure. The most frequent type of recurrence was paroxysmal AF in SRterm patients and AT in ATterm patients. CONCLUSIONS: Patients who terminate to SR through ablation without an intermediate AT are characterized by a less altered arrhythmogenic substrate. Baseline AF cycle lengths emerged as a sole independent predictor of a substrate for consecutive arrhythmias.


Subject(s)
Atrial Fibrillation/surgery , Catheter Ablation , Tachycardia, Supraventricular/etiology , Aged , Atrial Fibrillation/complications , Atrial Fibrillation/epidemiology , Atrial Fibrillation/physiopathology , Catheter Ablation/adverse effects , Chi-Square Distribution , Electrocardiography , Electrophysiologic Techniques, Cardiac , Humans , Logistic Models , Middle Aged , Recurrence , Reoperation , Risk Assessment , Risk Factors , Tachycardia, Supraventricular/epidemiology , Tachycardia, Supraventricular/physiopathology , Time Factors , Treatment Outcome
10.
J Cardiovasc Electrophysiol ; 21(10): 1079-84, 2010 Oct.
Article in English | MEDLINE | ID: mdl-20455974

ABSTRACT

AIMS: A robotic navigation system (RNS, Hansen™) has been developed as an alternative method of performing ablation for atrial fibrillation (AF). Despite the growing application of RNS-guided pulmonary vein isolation (PVI), its consequences and mechanisms of subsequent AF recurrences are unknown. We investigated the acute procedural success and persistence of PVI over time after robotic PVI and its relation to clinical outcome. METHODS AND RESULTS: Sixty-four patients (60.7 ± 9.8 years, 53 male) with paroxysmal AF underwent robotic circumferential PVI with 3-dimensional left atrial reconstruction (NavX™). A voluntary repeat invasive electrophysiological study was performed 3 months after ablation irrespective of clinical course. Robotic PVI was successful in all patients without complication (fluoroscopy time: 23.5 [12-34], procedure time: 180 [150-225] minutes). Fluoroscopy time demonstrated a gradual decline but was significantly reduced after the 30th patient following the introduction of additional navigation software (34 [29-45] vs 12 [9-17] minutes; P < 0.001). A repeat study at 3 months was performed in 63% of patients and revealed electrical conduction recovery in 43% of all PVs. Restudied patients without AF recurrence (n = 28) showed a significantly lower number of recovered PVs (1 (0-2) vs 2 (2-3); P = 0.006) and a longer LA-PV conduction delay than patients with AF recurrences (n = 12). Persistent block of all PVs was associated with freedom from AF in all patients. At 3 months, 67% of patients were free of AF, while reablation of recovered PVs led to an overall freedom from AF in 81% of patients after 1 year. CONCLUSION: Robotic PVI for PAF is safe, effective, and requires limited fluoroscopy while yielding comparable success rates to conventional ablation approaches with PV reconduction as a common phenomenon associated with AF recurrences.


Subject(s)
Atrial Fibrillation/surgery , Heart Conduction System/surgery , Pulmonary Veins/surgery , Robotics/methods , Surgery, Computer-Assisted/methods , Telemedicine/methods , Atrial Fibrillation/diagnosis , Female , Humans , Male , Middle Aged , Recurrence , Treatment Outcome
11.
Circ Arrhythm Electrophysiol ; 3(2): 160-9, 2010 Apr.
Article in English | MEDLINE | ID: mdl-20133933

ABSTRACT

BACKGROUND: Atrial tachycardias (AT) often occur after ablation of long-lasting persistent AF (CAF) and are difficult to treat conservatively. This study evaluated mechanisms and success rates of conventional mapping and catheter ablation of recurrent ATs occurring late after stepwise ablation of CAF. METHODS AND RESULTS: A total of 320 patients underwent de novo ablation of CAF using a stepwise ablation approach in 2006 to 2007 at our institution. This study comprised patients who presented with recurrent ATs at their first redo procedure after initial de novo CAF ablation. All procedures were guided by conventional mapping techniques exclusively. Sixty-one patients (63+/-10 years, 14 women) presented with their clinical AT at their redo procedure 7.7+/-4.4 months after initial de novo CAF ablation. A total of 133 ATs (2.2+/-0.9 per patient) were mapped. Forty-four (72%) were due to reentry; 17 (28%) were focal ATs. Reentry ATs were mainly characterized as roof and perimitral flutter (43% and 34%, respectively). Focal ATs mainly originated from the great thoracic veins (pulmonary veins: 41%, coronary sinus: 23%). Forty-five (74%) patients had conduction recovery of at least 1 pulmonary vein (mean, 1.2+/-0.8). Overall, 124 (93%) ATs could be ablated successfully. The mean procedure duration was 181+/-59 minutes, with a mean fluoroscopy time of 45+/-21 minutes. After a mean follow-up of 21+/-4 months, 50 (82%) patients were free of any arrhythmia recurrences after a single redo procedure. CONCLUSIONS: Although late recurrent ATs may have complex mechanisms, catheter ablation guided exclusively by conventional techniques is highly effective with excellent acute and long-term success rates.


Subject(s)
Atrial Fibrillation/physiopathology , Atrial Fibrillation/surgery , Catheter Ablation/statistics & numerical data , Tachycardia, Ectopic Atrial/physiopathology , Tachycardia, Ectopic Atrial/surgery , Aged , Atrial Fibrillation/epidemiology , Electrocardiography/statistics & numerical data , Electrophysiologic Techniques, Cardiac/statistics & numerical data , Female , Follow-Up Studies , Humans , Male , Middle Aged , Postoperative Complications/epidemiology , Recurrence , Tachycardia, Ectopic Atrial/epidemiology , Treatment Outcome
12.
J Cardiovasc Electrophysiol ; 21(1): 6-12, 2010 Jan.
Article in English | MEDLINE | ID: mdl-19793149

ABSTRACT

BACKGROUND: Recently, a nonmagnetic robotic navigation system (RN, Hansen-Sensei) has been introduced for remote catheter manipulation. OBJECTIVE: To investigate the influence of RN combined with intuitive 3-dimensional mapping on the fluoroscopy exposure to operator and patient during pulmonary vein isolation (PVI) for paroxysmal atrial fibrillation (PAF) in a prospective randomized trial. METHODS: Sixty patients were randomly assigned to undergo PVI either using a RN guided (group 1; n = 30, 20 male, 62 +/- 7.7 years) or conventional ablation approach (group 2; n = 30, 14 male, 61 +/- 7.6 years). A 3-dimensional mapping system (NavX) was used in both groups. RESULTS: Electrical disconnection of the ipsilateral pulmonary veins (PVs) was achieved in all patients. Use of RN significantly lowered the overall fluoroscopy time (9 +/- 3.4 vs 22 +/- 6.5 minutes; P < 0.001) and reduced the operator's fluoroscopy exposure (7 +/- 2.1 vs 22 +/- 6.5 minutes; P < 0.001). The difference in fluoroscopy duration between both groups was most pronounced during the ablation part of the procedure (3 +/- 2.4 vs 17 +/- 6.3 minutes; P < 0.001). The overall procedure duration tended to be prolonged using RN without reaching statistical significance (156 +/- 44.4 vs 134 +/- 12 minutes, P = 0.099). No difference regarding outcome was found during a midterm follow-up of 6 months (AF freedom group 1 = 73% vs 77% in group 2 [P = 0.345]). CONCLUSION: The use of RN for PVI seems to be effective and significantly reduces overall fluoroscopy time and operator's fluoroscopy exposure without affecting mid-term outcome after 6-month follow-up.


Subject(s)
Atrial Fibrillation/diagnostic imaging , Atrial Fibrillation/surgery , Body Surface Potential Mapping/methods , Catheter Ablation/methods , Radiation Dosage , Robotics/methods , Surgery, Computer-Assisted/methods , Female , Humans , Male , Middle Aged , Radiography , Treatment Outcome
13.
Eur Heart J ; 31(4): 450-6, 2010 Feb.
Article in English | MEDLINE | ID: mdl-19897495

ABSTRACT

AIMS: We investigated the feasibility of real-time magnetic resonance imaging (RTMRI) guided ablation of the cavotricuspid isthmus (CTI) by using a MRI-compatible ablation catheter. METHODS AND RESULTS: Cavotricuspid isthmus ablation was performed in an interventional RTMRI suite by using a novel 7 French, steerable, non-ferromagnetic ablation catheter in a porcine in vivo model (n = 20). The catheter was introduced and navigated by RTMRI visualization only. Catheter position and movement during manipulation were continuously visualized during the entire intervention. Two porcine prematurely died due to VT/VF. Anatomical completion of the CTI ablation line could be achieved after a mean of 6.3+/-3 RF pulses (RF energy: 1807+/-1016.4 Ws/RF pulse, temperature: 55.9+/-5.9 degrees C) in n = 18 animals. In 15 of 18 procedures (83.3%) a complete CTI block was proven by conventional mapping in the electrophysiological (EP) lab. CONCLUSION: Completely non-fluoroscopic ablation guided by RTMRI using a steerable and non-ferromagnetic catheter is a promising novel technology in interventional electrophysiology.


Subject(s)
Atrial Flutter/surgery , Catheter Ablation/methods , Tricuspid Valve/surgery , Animals , Electrophysiology , Feasibility Studies , Magnetic Resonance Angiography , Magnetic Resonance Imaging, Interventional , Swine
15.
Europace ; 11(10): 1362-8, 2009 Oct.
Article in English | MEDLINE | ID: mdl-19797150

ABSTRACT

AIMS: Electrocardiographic changes, e.g. arrhythmias causing syncope or palpitations, are often transient and therefore difficult to diagnose. Systematic and symptom-activated ECG recordings can increase diagnostic yield in such patients. We evaluated the diagnostic accuracy of a simple, leadless, patient-operated ECG device compared with a standard 12-lead ECG. METHODS AND RESULTS: We recorded a standard 12-lead surface ECG and a patient-activated ECG in direct succession in 508 consecutive patients enrolled in four centres. All ECGs were analysed by a single, blinded observer. ECGs were analysable in 505 (99.4%) patients (66% male, age 61 +/- 15 years, and body mass index 27 +/- 4). Analysis of the patient-activated ECG adequately detected a normal ECG (sensitivity 91% and specificity 95%), atrial fibrillation (AF) (sensitivity 99% and specificity 96%), and even T-wave abnormalities (sensitivity 90% and specificity 75%). Diagnostic accuracy for atrioventricular nodal block was moderate (sensitivity 79% and specificity 99%). Continuous parameters correlated well: (r(2) = 0.89 for heart rate, 0.83 for PR interval, 0.78 for QRS duration, and 0.89 for QTc). CONCLUSION: Recordings made by this patient-operated ECG device allow to detect arrhythmias and other ECG changes with high accuracy compared with a standard ECG. It may help to improve accurate diagnosis of transient ECG changes such as paroxysmal AF in palpitations or other unexplained cardiac symptoms.


Subject(s)
Arrhythmias, Cardiac/diagnosis , Electrocardiography, Ambulatory/instrumentation , Electrocardiography/instrumentation , Self Care/instrumentation , Telemedicine/instrumentation , Adolescent , Adult , Aged , Aged, 80 and over , Equipment Design , Equipment Failure Analysis , Female , Germany , Humans , Male , Middle Aged , Reproducibility of Results , Sensitivity and Specificity , Young Adult
16.
J Cardiovasc Electrophysiol ; 20(5): 522-5, 2009 May.
Article in English | MEDLINE | ID: mdl-19207748

ABSTRACT

INTRODUCTION: Radiofrequency catheter ablation aiming slow pathway modulation is a widely established procedure with high success and low recurrence rates in patients with atrioventricular nodal reentry tachycardia (AVNRT). However, the necessity of a waiting period following successful slow pathway modulation to increase the long-term success rates has not been systematically evaluated thus far. METHODS AND RESULTS: This prospective study comprised 138 consecutive patients (mean age 50.3 +/- 15.1 years) with AVNRT. These patients were randomly assigned to two groups: in group I (n = 70), a waiting period of 30 min was part of the procedure, whereas in group II (n = 68), the procedure ended without a waiting period. Electrophysiological standard parameters, i.e., ERP of RA, fast and slow pathway, RV as well as antegrade and retrograde AV node conduction capacity, were assessed prior to and after the ablation. During a follow-up period of 22.8 +/- 5.9 months, four patients in group I and three patients in group II developed recurrence of AVNRT (4.9%; P = 0.4). The mean procedure time was 115.1 +/- 23.6 min in the group with and 88.9 +/- 23.3 min in the group without waiting period (P = 0.009). No high degree AV-node conduction block was observed during the study. CONCLUSION: In the present study we could show that no long-term benefit results from a 30 min waiting period for patients who underwent an acutely successful catheter ablation for AVNRT. We therefore conclude that a 30-min waiting period can be omitted in standard procedures, thus resulting in significant shorter procedure durations.


Subject(s)
Catheter Ablation/methods , Tachycardia, Atrioventricular Nodal Reentry/diagnosis , Tachycardia, Atrioventricular Nodal Reentry/surgery , Female , Humans , Male , Middle Aged , Time Factors , Treatment Outcome
17.
Heart Rhythm ; 5(11): 1556-60, 2008 Nov.
Article in English | MEDLINE | ID: mdl-18984532

ABSTRACT

BACKGROUND: Conventional catheter ablation for common-type atrial flutter (AFL) is a widely established therapy but has not been compared with the use of a robotic navigation system (RNS) thus far. OBJECTIVES: The purpose of this study was to investigate the feasibility of a new, nonmagnetic RNS with regard to safety, efficacy, and X-ray exposure to investigator and patient compared with the conventional ablation approach in patients with AFL. METHODS: Fifty patients (65.7 +/- 9.3 years, 40 male) undergoing de novo catheter ablation for AFL were randomly assigned to conventional or RNS-guided cavotricuspid isthmus (CTI) ablation. RESULTS: Complete bidirectional isthmus block was achieved for all patients without occurrence of procedure-related complications. The fluoroscopy time and the investigator X-ray exposure (8.2 +/- 4.6 vs. 5.8 +/- 3.6, P = .038; and 8.2 +/- 4.6 vs. 1.9 +/- 1.1 minutes, P<.001) as well as the mean radiofrequency (RF) duration and the energy delivered were significantly higher in the conventional than in the RNS group (321.7 +/- 214.6 vs. 496.4 +/- 213.9 seconds, P = .006; 8279 +/- 5767 vs. 16,308 +/- 6870 J, P<.001, respectively). The overall procedure time in the RNS group was significantly longer than in the conventional group (79.2 +/- 30.6 vs. 58.4 +/- 17.7 minutes; P = .04) but significantly decreased comparing the first 10 with the last 10 patients in the RNS group (105.3 +/- 34.8 vs. 60.6 +/- 6.3 minutes; P = .003). Starting ablation during AFL, bidirectional block instantly after termination was observed in 90% of the RNS and 50% of the conventionally treated patients (P = .03). CONCLUSION: The present study demonstrates the safety and feasibility of RNS for performing CTI ablation in patients with common-type AFL for use in the clinical routine. As a result of the remote navigation, X-ray exposure and RF duration to achieve bidirectional block were significantly decreased and occurred more often immediately after AFL termination. These findings are consistent with increased catheter stability and RF application efficacy using RNS compared with conventional catheter manipulation.


Subject(s)
Atrial Flutter/surgery , Catheter Ablation/methods , Robotics , Aged , Catheter Ablation/instrumentation , Equipment Design , Female , Heart Conduction System/surgery , Humans , Male , Middle Aged , Prospective Studies , Treatment Outcome
18.
J Am Coll Cardiol ; 51(22): 2153-60, 2008 Jun 03.
Article in English | MEDLINE | ID: mdl-18510963

ABSTRACT

OBJECTIVES: Our purpose was to investigate the impact of short-lasting atrial fibrillation (AF) on the electrophysiological properties of the atria and pulmonary veins (PVs) in patients devoid of AF. BACKGROUND: The presence of AF is associated with electrical remodeling processes that promote a substrate for arrhythmia maintenance in the atria, which has been termed "AF begets AF." However, it is unclear whether those electrical alterations also occur in the PVs. METHODS: Thirty-five patients with a left-sided accessory pathway and without a prior history of AF were included. After successful ablation, the effective refractory periods (ERPs) and conduction times of the right atrium (RA), left atrium (LA), and the PVs were determined. Afterwards, AF was induced and maintained for a period of 15 min. Thereafter, the stimulation protocol was repeated. RESULTS: At baseline, the PVs had significantly longer ERPs than the atria. After exposure to AF, the ERPs of both the atria and the PVs decreased significantly. The ERPs of the PVs, however, decreased by a significantly greater extent than the ERPs of the atria (PVs: 248 +/- 27 ms vs. 211 +/- 40 ms, p < 0.001; LA: 233 +/- 23 ms vs. 214 +/- 20 ms, p = 0.004; RA: 226 +/- 29 ms vs. 188 +/- 20 ms; p = 0.003). After AF exposure, the PVs demonstrated a significant conduction slowing whereas the atria did not (PVs: 125 +/- 33 ms vs. 159 +/- 37 ms, p < 0.001; LA: 129 +/- 26 ms vs. 130 +/- 24 ms, p = NS; RA: 192 +/- 36 ms vs. 196 +/- 32 ms, p = NS). Finally, AF was more frequently induced after the presence of AF, particularly by pacing in the PVs (14% vs. 49%, p = 0.001). CONCLUSIONS: New-onset, short-lasting AF creates electrical characteristics similar to those of patients with AF. However, these alterations are pronounced in the PVs compared with the atria, indicating that "AF begets AF in the PVs" (Electrophysiological Properties of the Pulmonary Veins; NCT00530608).


Subject(s)
Atrial Fibrillation/physiopathology , Catheter Ablation/methods , Pulmonary Veins/physiopathology , Adult , Atrial Fibrillation/surgery , Coronary Vessels/physiopathology , Electrophysiology , Female , Heart Atria/physiopathology , Heart Conduction System/physiopathology , Humans , Male , Prospective Studies , Time Factors
19.
Europace ; 10(5): 593-9, 2008 May.
Article in English | MEDLINE | ID: mdl-18385123

ABSTRACT

AIMS: Beneficial effects of atrial fibrillation (AF) ablation have been demonstrated in patients with congestive heart failure (CHF) and significantly impaired left ventricular ejection fraction (LVEF). However, the impact of pulmonary vein isolation (PVI) on cardiac function in patients with paroxysmal AF and impaired LVEF remains under discussion. This study aimed to evaluate the impact of PVI for paroxysmal AF on cardiac function in patients with impaired LVEF using cardiac magnetic resonance imaging (CMRI). METHODS AND RESULTS: A total number of 70 patients with paroxysmal AF and episodes < or = 24 h were scanned on a 1.5-T-CMRI before and 6 months after PVI during sinus rhythm. End-diastolic volume, end-systolic volume, and LVEF were determined by epicardial and endocardial measurements. Patients were categorized into two groups regarding cardiac function as assessed by CMRI: group 1 patients (n = 18) with an LVEF < 50% and patients with an LVEF > 50% (group 2, n = 52). Group 1 patients demonstrated a significant lower success rate than patients of group 2 after a follow-up of 152 +/- 40 days (50 vs. 73%, P < 0.05). Cardiac magnetic resonance imaging in group 1 patients demonstrated a significant improvement in cardiac function after AF ablation (41 +/- 6 vs. 51 +/- 12%, P = 0.004), whereas group 2 patients did not show significant differences (60 +/- 6 vs. 59 +/- 9%, P = 0.22) after a 6 months follow-up. CONCLUSION: Pulmonary vein isolation improves cardiac function in patients with paroxysmal AF and impaired LVEF. These data suggest that an impaired LV function can be partially attributed to AF with short-lasting paroxysms.


Subject(s)
Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Catheter Ablation/methods , Ventricular Dysfunction, Left/diagnosis , Ventricular Dysfunction, Left/surgery , Atrial Fibrillation/complications , Female , Heart Conduction System/surgery , Humans , Male , Middle Aged , Pulmonary Veins/surgery , Treatment Outcome , Ventricular Dysfunction, Left/complications
SELECTION OF CITATIONS
SEARCH DETAIL
...