Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
Add more filters










Database
Language
Publication year range
2.
Rev Sci Instrum ; 94(5)2023 May 01.
Article in English | MEDLINE | ID: mdl-37191465

ABSTRACT

Control noise is a limiting factor in the low-frequency performance of the Advanced Laser Interferometer Gravitational-Wave Observatory (LIGO). In this paper, we model the effects of using new sensors called Homodyne Quadrature Interferometers (HoQIs) to control the suspension resonances. We show that if we were to use HoQIs, instead of the standard shadow sensors, we could suppress resonance peaks up to tenfold more while simultaneously reducing the noise injected by the damping system. Through a cascade of effects, this will reduce the resonant cross-coupling of the suspensions, allow for improved stability for feed-forward control, and result in improved sensitivity of the detectors in the 10-20 Hz band. This analysis shows that improved local sensors, such as HoQIs, should be used in current and future detectors to improve low-frequency performance.

3.
Science ; 372(6548): 1333-1336, 2021 06 18.
Article in English | MEDLINE | ID: mdl-34140386

ABSTRACT

The motion of a mechanical object, even a human-sized object, should be governed by the rules of quantum mechanics. Coaxing them into a quantum state is, however, difficult because the thermal environment masks any quantum signature of the object's motion. The thermal environment also masks the effects of proposed modifications of quantum mechanics at large mass scales. We prepared the center-of-mass motion of a 10-kilogram mechanical oscillator in a state with an average phonon occupation of 10.8. The reduction in temperature, from room temperature to 77 nanokelvin, is commensurate with an 11 orders-of-magnitude suppression of quantum back-action by feedback and a 13 orders-of-magnitude increase in the mass of an object prepared close to its motional ground state. Our approach will enable the possibility of probing gravity on massive quantum systems.

4.
Phys Rev Lett ; 121(22): 221104, 2018 Nov 30.
Article in English | MEDLINE | ID: mdl-30547651

ABSTRACT

Newtonian gravitational noise from seismic fields will become a limiting noise source at low frequency for second-generation, gravitational-wave detectors. It is planned to use seismic sensors surrounding the detectors' test masses to coherently subtract Newtonian noise using Wiener filters derived from the correlations between the sensors and detector data. In this Letter, we use data from a seismometer array deployed at the corner station of the Laser Interferometer Gravitational Wave Observatory (LIGO) Hanford detector combined with a tiltmeter for a detailed characterization of the seismic field and to predict achievable Newtonian-noise subtraction levels. As was shown previously, cancellation of the tiltmeter signal using seismometer data serves as the best available proxy of Newtonian-noise cancellation. According to our results, a relatively small number of seismometers is likely sufficient to perform the noise cancellation due to an almost ideal two-point spatial correlation of seismic surface displacement at the corner station, or alternatively, a tiltmeter deployed under each of the two test masses of the corner station at Hanford will be able to efficiently cancel Newtonian noise. Furthermore, we show that the ground tilt to differential arm-length coupling observed during LIGO's second science run is consistent with gravitational coupling.

6.
Rev Sci Instrum ; 88(12): 124501, 2017 Dec.
Article in English | MEDLINE | ID: mdl-29289175

ABSTRACT

This paper presents an analysis of the transient behavior of the Advanced LIGO (Laser Interferometer Gravitational-wave Observatory) suspensions used to seismically isolate the optics. We have characterized the transients in the longitudinal motion of the quadruple suspensions during Advanced LIGO's first observing run. Propagation of transients between stages is consistent with modeled transfer functions, such that transient motion originating at the top of the suspension chain is significantly reduced in amplitude at the test mass. We find that there are transients seen by the longitudinal motion monitors of quadruple suspensions, but they are not significantly correlated with transient motion above the noise floor in the gravitational wave strain data, and therefore do not present a dominant source of background noise in the searches for transient gravitational wave signals. Using the suspension transfer functions, we compared the transients in a week of gravitational wave strain data with transients from a quadruple suspension. Of the strain transients between 10 and 60 Hz, 84% are loud enough that they would have appeared above the sensor noise in the top stage quadruple suspension monitors if they had originated at that stage at the same frequencies. We find no significant temporal correlation with the suspension transients in that stage, so we can rule out suspension motion originating at the top stage as the cause of those transients. However, only 3.2% of the gravitational wave strain transients are loud enough that they would have been seen by the second stage suspension sensors, and none of them are above the sensor noise levels of the penultimate stage. Therefore, we cannot eliminate the possibility of transient noise in the detectors originating in the intermediate stages of the suspension below the sensing noise.

7.
Haemophilia ; 18(3): 375-82, 2012 May.
Article in English | MEDLINE | ID: mdl-22103590

ABSTRACT

Both genetic and treatment-related risk factors contribute to the development of inhibitors in haemophilia. An inhibitor surveillance system piloted at 12 US sites has the goal of assessing risk factors through prospective data collection. This report examines the relationship of genotype and race/ethnicity to history of inhibitor in a large cohort of US haemophilia patients. Mutation analysis was performed on 676 haemophilia A (HA) and 153 haemophilia B (HB) patients by sequencing, Multiplex Ligation-dependent Probe Amplification, and PCR for inversions in F8 introns 22 (inv22) and 1 (inv1). Two HB patients with deletions had history of inhibitor. In severe HA, frequency of history of inhibitor was: large deletion 57.1%, splice site 35.7%, inv22 26.8%, nonsense 24.5%, frameshift 12.9%, inv1 11.1% and missense 9.5%. In HA, 19.6% of 321 White non-Hispanics (Whites), 37.1% of 35 Black non-Hispanics (Blacks) and 46.9% of 32 Hispanics had history of inhibitor (P = 0.0003). Mutation types and novel mutation rates were similar across ethnicities. When F8 haplotypes were constructed, Whites and Hispanics showed only H1 and H2. Within H1, history of inhibitor was 12.4% in Whites, 40.0% in Blacks (P = 0.009) and 32.4% in Hispanics (P = 0.002). Inhibitor frequency is confirmed to vary by mutation type and race in a large US population. White patients with history of inhibitor did not exhibit rare F8 haplotypes. F8 gene analysis did not reveal a cause for the higher inhibitor frequencies in Black and Hispanic patients.


Subject(s)
Blood Coagulation Factor Inhibitors/blood , Factor IX/genetics , Factor VIII/genetics , Hemophilia A/genetics , Hemophilia B/genetics , Mutation , Adolescent , Adult , Autoantibodies/blood , Child , Child, Preschool , Cohort Studies , Factor IX/antagonists & inhibitors , Factor IX/immunology , Factor VIII/antagonists & inhibitors , Factor VIII/immunology , Genetic Predisposition to Disease , Genotype , Hemophilia A/ethnology , Hemophilia A/immunology , Hemophilia B/ethnology , Hemophilia B/immunology , Humans , Infant , Introns/genetics , Male , United States/ethnology , Young Adult
SELECTION OF CITATIONS
SEARCH DETAIL
...