Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add more filters










Database
Language
Publication year range
1.
Phys Med Biol ; 64(1): 015013, 2018 12 21.
Article in English | MEDLINE | ID: mdl-30523869

ABSTRACT

Clinical trials have shown that hyperthermia is a potent adjuvant to conventional cancer treatments, but the temperatures currently achieved in the clinic are still suboptimal. Hyperthermia treatment planning simulations have potential to improve the heating profile of phased-array applicators. An important open challenge is the development of an effective optimization procedure that enables uniform heating of the target region while keeping temperature below a threshold in healthy tissues. In this work, we analyzed the effectiveness and efficiency of a recently proposed optimization approach, i.e. focusing via constrained power optimization (FOCO), using 3D simulations of twelve clinical patient specific models. FOCO performance was compared against a clinically used particle swarm based optimization approach. Evaluation metrics were target coverage at the 25% iso-SAR level, target hotspot quotient, median target temperature (T50) and computational requirements. Our results show that, on average, constrained power focusing performs slightly better than the clinical benchmark ([Formula: see text]T50 [Formula: see text] °C), but outperforms this clinical benchmark for large target volumes ([Formula: see text]40 cm[Formula: see text], [Formula: see text]T50 [Formula: see text] °C). In addition, the results are achieved in a shorter time ([Formula: see text]%) and are repeatable because the approach is formulated as a convex optimization problem.


Subject(s)
Head and Neck Neoplasms/therapy , Hyperthermia, Induced/methods , Algorithms , Humans , Hyperthermia, Induced/standards
2.
Phys Med Biol ; 63(13): 135023, 2018 07 06.
Article in English | MEDLINE | ID: mdl-29863491

ABSTRACT

Clinical studies have shown that hyperthermia sensitizes tumor cells for conventional therapies. During phased-array microwave hyperthermia, an array of antennas is used to focus the electromagnetic waves at the target region. Selective heating, while preserving the healthy tissue, is a demanding challenge and currently patient specific pre-treatment planning is used to optimize the amplitudes and phases of the waves. In addition, when needed, this single optimal heat distribution is adapted using the simulations based on the feedback from thermo-sensors and the patient. In this paper, we hypothesize that sequential, i.e. 'time-multiplexed', application of multiple Pareto optimal heating patterns provides a better time-averaged treatment quality. To test the benefit of such a time-multiplexed approach, a multi-objective genetic algorithm was introduced to balance two objectives that both focus the specific absorption rate (SAR) delivered to the target region but differ in the suppressing of pre-defined hotspots. This step leads to two Pareto optimal distributions. These 'diverse' antenna settings are then applied sequentially and thermal simulations are used to evaluate the effectiveness of the time-multiplexed steering. The proposed technique is tested using treatment planning data of a representative dataset of five head and neck patients for the HYPERcollar3D. Steering dynamics are analysed and the time-multiplexed steering is compared to the current static solution used in the clinic, i.e. hotspot-target SAR quotient optimization using particle swarm optimization. Our results demonstrate that realistic steering periods of 10s suffice to stabilize temperatures within 0.04 °C and the ability to enhance target heating while reducing hotspots, i.e. 0.3 °C-1.2 °C improvement in T 50 while reducing hotspot temperatures by 0.6 °C-1.5 °C.


Subject(s)
Algorithms , Head and Neck Neoplasms/physiopathology , Head and Neck Neoplasms/therapy , Hyperthermia, Induced/instrumentation , Hyperthermia, Induced/methods , Microwaves/therapeutic use , Therapy, Computer-Assisted/methods , Female , Humans , Male , Middle Aged , Thermal Conductivity
3.
IEEE Trans Biomed Eng ; 64(8): 1875-1885, 2017 08.
Article in English | MEDLINE | ID: mdl-28113287

ABSTRACT

Hyperthermia is an emerging cancer treatment modality, which involves applying heat to the malignant tumor. The heating can be delivered using electromagnetic (EM) energy, mostly in the radiofrequency (RF) or microwave range. Accurate patient-specific hyperthermia treatment planning (HTP) is essential for effective and safe treatments, in particular, for deep and loco-regional hyperthermia. An important aspect of HTP is the ability to focus microwave energy into the tumor and reduce the occurrence of hot spots in healthy tissue. This paper presents a method for optimizing the specific absorption rate (SAR) distribution for the head and neck cancer hyperthermia treatment. The SAR quantifies the rate at which localized RF or microwave energy is absorbed by the biological tissue when exposed to an EM field. A differential evolution (DE) optimization algorithm is proposed in order to improve the SAR coverage of the target region. The efficacy of the proposed algorithm is demonstrated by testing with the Erasmus MC patient dataset. DE is compared to the particle swarm optimization (PSO) method, in terms of average performance and standard deviation and across various clinical metrics, such as the hot-spot-tumor SAR quotient (HTQ), treatment quantifiers, and temperature parameters. While hot spots in the SAR distribution remain a problem with current approaches, DE enhances focusing microwave energy absorption to the target region during hyperthermia treatment. In particular, DE offers improved performance compared to the PSO algorithm currently deployed in the clinic, reporting a range of improvement of HTQ standard deviation of between 40.1-96.8% across six patients.


Subject(s)
Absorption, Radiation , Body Temperature/radiation effects , Head and Neck Neoplasms/physiopathology , Head and Neck Neoplasms/therapy , Hyperthermia, Induced/methods , Models, Biological , Therapy, Computer-Assisted/methods , Computer Simulation , Dose-Response Relationship, Radiation , Energy Transfer , Humans , Microwaves/therapeutic use , Reproducibility of Results , Sensitivity and Specificity , Thermal Conductivity , Treatment Outcome
4.
Phys Med Biol ; 62(5): 1831-1847, 2017 03 07.
Article in English | MEDLINE | ID: mdl-28052042

ABSTRACT

Biological studies and clinical trials show that addition of hyperthermia stimulates conventional cancer treatment modalities and significantly improves treatment outcome. This supra-additive stimulation can be optimized by adaptive hyperthermia to counteract strong and dynamic thermoregulation. The only clinically proven method for the 3D non-invasive temperature monitoring required is by magnetic resonance (MR) temperature imaging, but the currently available set of MR compatible hyperthermia applicators lack the degree of heat control required. In this work, we present the design and validation of a high-frequency (433 MHz ISM band) printed circuit board antenna with a very low MR-footprint. This design is ideally suited for use in a range of hyperthermia applicator configurations. Experiments emulating the clinical situation show excellent matching properties of the antenna over a 7.2% bandwidth (S 11 < -15 dB). Its strongly directional radiation properties minimize inter-element coupling for typical array configurations (S 21 < -23 dB). MR imaging distortion by the antenna was found negligible and MR temperature imaging in a homogeneous muscle phantom was highly correlated with gold-standard probe measurements (root mean square error: RMSE = 0.51 °C and R 2 = 0.99). This work paves the way for tailored MR imaging guided hyperthermia devices ranging from single antenna or incoherent antenna-arrays, to real-time adaptive hyperthermia with phased-arrays.


Subject(s)
Hyperthermia, Induced/methods , Magnetic Resonance Imaging/methods , Microwaves/therapeutic use , Thermometry/methods , Hyperthermia, Induced/instrumentation , Magnetic Resonance Imaging/instrumentation , Neoplasms/therapy , Phantoms, Imaging , Thermometry/instrumentation
5.
Phys Med Biol ; 57(9): 2491-503, 2012 May 07.
Article in English | MEDLINE | ID: mdl-22493169

ABSTRACT

In the current clinical practice, prior to superficial hyperthermia treatments (HT), temperature probes are placed in tissue to document a thermal dose. To investigate whether the painful procedure of catheter placement can be replaced by superficial HT planning, we study if the specific absorption rate (SAR) coverage is predictive for treatment outcome. An absolute requirement for such a study is the accurate reconstruction of the applicator setup. The purpose of this study was to investigate the feasibility of the applicator setup reconstruction from multiple-view images. The accuracy of the multiple-view reconstruction method has been assessed for two experimental setups using six lucite cone applicators (LCAs) representing the largest array applied at our clinic and also the most difficult scenario for the reconstruction. For the two experimental setups and 112 distances, the mean difference between photogrametry reconstructed and manually measured distances was 0.25 ± 0.79 mm (mean±1 standard deviation). By a parameter study of translation T (mm) and rotation R (°) of LCAs, we showed that these inaccuracies are clinically acceptable, i.e. they are either from ±1.02 mm error in translation or ±0.48° in rotation, or combinations expressed by 4.35R(2) + 0.97T(2) = 1. We anticipate that such small errors will not have a relevant influence on the SAR distribution in the treated region. The clinical applicability of the procedure is shown on a patient with a breast cancer recurrence treated with reirradiation plus superficial hyperthermia using the six-LCA array. The total reconstruction procedure of six LCAs from a set of ten photos currently takes around 1.5 h. We conclude that the reconstruction of superficial HT setup from multiple-view images is feasible and only minor errors are found that will have a negligible influence on treatment planning quality.


Subject(s)
Hyperthermia, Induced/instrumentation , Image Processing, Computer-Assisted , Radiotherapy Planning, Computer-Assisted/instrumentation , Absorption , Feasibility Studies , Humans , Photography , Polymethyl Methacrylate , Treatment Outcome
6.
Int J Hyperthermia ; 26(7): 638-48, 2010.
Article in English | MEDLINE | ID: mdl-20849259

ABSTRACT

For superficial hyperthermia a custom-built multi-applicator multi-amplifier superficial hyperthermia system operating at 433 MHz is utilised. Up to 6 Lucite Cone applicators can be used simultaneously to treat an area of 600 cm2. Temperatures are measured continuously with fibre optic multi-sensor probes. For patients with non-standard clinical problems, hyperthermia treatment planning is used to support decision making with regard to treatment strategy. In 74% of our patients with recurrent breast cancer treated with a reirradiation scheme of 8 fractions of 4 Gy in 4 weeks, combined with 4 or 8 hyperthermia treatments, a complete response is achieved, approximately twice as high as the CR rate following the same reirradation alone. The CR rate in tumours smaller than 30 mm is 80-90%, for larger tumours it is 65%. Hyperthermia appears beneficial for patients with microscopic residual tumour as well. To achieve high CR rates it is important to heat the whole radiotherapy field, and to use an adequate heating technique.


Subject(s)
Breast Neoplasms/therapy , Breast Neoplasms/radiotherapy , Combined Modality Therapy , Dose Fractionation, Radiation , Female , Humans , Recurrence
SELECTION OF CITATIONS
SEARCH DETAIL
...