1.
AORN J ; 118(2): 79-86, 2023 08.
Article in English | MEDLINE | ID: mdl-37493426

ABSTRACT

The use of performance qualification (PQ) tests for ultrasonic cleaners leads to improvements in the quality of processing lumened surgical instruments. Evidence and national standards assert the need for health care facilities to implement a quality management system related to device reprocessing and testing the adequacy of mechanical cleaning processes. Testing includes showing that ultrasonic cleaners have properly functioning cavitation, soil removal, and lumen perfusion capabilities. This article summarizes survey responses from an audit of sterile processing personnel regarding ultrasonic cleaning units in health care facilities. The article also provides guidance to facilities regarding assessing installation, operational, and PQ related to ultrasonic cleaning equipment. Implementing PQ testing of ultrasonic cleaners in sterile processing units leads to a decreased risk of soiled instrumentation in the OR, which can reduce the risk of patient infection and adverse events.


Subject(s)
Sterilization , Ultrasonics , Humans , Surgical Instruments , Health Facilities
2.
Biomed Instrum Technol ; 57(2): 44-51, 2023.
Article in English | MEDLINE | ID: mdl-37343068

ABSTRACT

Background: Cleaning is essential to ensuring the safe processing of reusable medical devices, and most manufacturers' instructions for use (IFUs) specify that clinical soil should not be allowed to dry on devices. If soil is allowed to dry, the cleaning challenge could be increased due to change in soil solubility. As a result, an additional step could be needed to reverse the chemical changes and return a device to a state where cleaning instructions are appropriate. Methods: Using a solubility test method and surrogate medical devices, the experiment described in this article challenged eight remediation conditions to which a reusable medical device might be exposed if soil is dried on a device. These conditions included soaking with water or neutral pH, enzymatic, or alkaline detergent cleaning agents, as well as conditioning with an enzymatic humectant foam spray. Results: The results demonstrated that only the alkaline cleaning agent was able to solubilize the extensively dried soil as effectively as the control, with a 15-minute soak being as effective as a 60-minute soak. Discussion: Although opinions vary, the overall data demonstrating the risk and chemical changes that occur when soil dries on medical devices are limited. Further, in cases in which soil is allowed to dry on devices for an extended time outside of the guidance from leading practices and manufacturers' IFUs, what additional steps or processes may be necessary to ensure that cleaning can be effective? Conclusion: This experiment demonstrated the effectiveness of a soaking step with an alkaline cleaning agent as an additional step if soil is dried on reusable medical devices, thus reversing the effect of an extended soil dry time.


Subject(s)
Disinfection , Equipment Reuse , Equipment and Supplies