Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
Eur J Cardiovasc Nurs ; 22(8): 780-785, 2023 Dec 14.
Article in English | MEDLINE | ID: mdl-36705579

ABSTRACT

AIMS: Hypertrophic cardiomyopathy (HCM) is the most common inherited heart disease. Insertable cardiac monitors (ICMs) are increasingly used in this population to provide closer monitoring, with the potential for notification systems. However, little is known regarding the psychological impact this information may have on patients. The Abbott Confirm Rx™ ICM has the capability of connecting to the patient's smartphone to enable active participation in their care, as well as two-way communication between the patient and their care providers. This study aimed to explore individuals' experiences of having a smartphone-enabled ICM to monitor for arrhythmias in HCM. METHODS AND RESULTS: Semi-structured interviews were conducted with 10 participants. Utilizing a grounded theory approach, the interview guide was modified based on emerging themes throughout the study. Reflexive thematic analysis was applied to categorize interview data into codes and overacting themes, with each interview independently coded by two study members. Analysis revealed three key themes: (i) psychological impact, (ii) educational needs, and (iii) technology expectations. Participants reported that receiving feedback from ICM transmissions resulted in improved symptom clarity, providing reassurance, and aiding implantable cardioverter defibrillator decision-making. Some participants reported uncertainty regarding when to send manual transmissions. Lastly, participants reported the app interface did not meet expectations with regard to the amount of data available for patients. CONCLUSION: Overall, utilizing a smartphone app to facilitate two-way communication of ICM transmissions was well accepted. Future directions include addressing gaps in educational needs and improvements in the patient interface with increased access to data.


Subject(s)
Cardiomyopathy, Hypertrophic , Defibrillators, Implantable , Humans , Arrhythmias, Cardiac/diagnosis , Arrhythmias, Cardiac/therapy , Electrocardiography , Defibrillators, Implantable/psychology , Cardiomyopathy, Hypertrophic/diagnosis , Cardiomyopathy, Hypertrophic/therapy , Cardiomyopathy, Hypertrophic/psychology , Patient Outcome Assessment
3.
CJC Open ; 4(4): 406-415, 2022 Apr.
Article in English | MEDLINE | ID: mdl-35495864

ABSTRACT

Hypertrophic cardiomyopathy (HCM) is the most common inherited cardiomyopathy, presenting significant clinical heterogeneity. Arrhythmia risk stratification and detection are critical components in the evaluation and management of all cases of HCM. The 2020 American Heart Association/American College of Cardiology HCM guidelines provide new recommendations for periodic 24-48-hour ambulatory electrocardiogram monitoring to screen for atrial and ventricular arrhythmias. A strategy of more frequent or prolonged monitoring would lead to earlier arrhythmia recognition and the potential for appropriate treatment. However, whether such a strategy in patients with HCM results in improved outcomes is not yet established. The available evidence, knowledge gaps, and potential merits of such an approach are reviewed. Cardiac implantable electronic devices provide an opportunity for early arrhythmia detection, with the potential to enable early management strategies in order to improve outcomes.


La cardiomyopathie hypertrophique (CMH) qui est la cardiomyopathie héréditaire la plus fréquente présente une hétérogénéité clinique importante. La stratification du risque d'arythmies et leur détection sont des composantes essentielles de l'évaluation et de la prise en charge de tous les cas de CMH. Les lignes directrices 2020 de l'American Heart Association et de l'American College of Cardiology en matière de CMH fournissent les nouvelles recommandations sur la surveillance périodique de l'électrocardiogramme ambulatoire de 24-48 heures pour dépister les arythmies auriculaires et ventriculaires. Une stratégie de surveillance plus fréquente et prolongée permettrait de dépister plus précocement l'arythmie et pourrait mener au traitement approprié. Toutefois, il n'a pas encore été établi qu'une telle stratégie chez les patients atteints de CMH entraînait de meilleurs résultats cliniques. Les données probantes actuelles, les lacunes en matière de connaissances et les mérites potentiels d'une telle approche sont passés en revue. Les dispositifs cardiaques électroniques implantables offrent la possibilité de détecter précocement l'arythmie et le potentiel de favoriser des stratégies de prise en charge précoce pour améliorer les résultats cliniques.

4.
CJC Open ; 4(3): 305-314, 2022 Mar.
Article in English | MEDLINE | ID: mdl-35386128

ABSTRACT

Background: Sudden cardiac death (SCD) risk stratification in hypertrophic cardiomyopathy (HCM) currently relies on arrhythmic burden quantification by 24 or 48-hour Holter monitoring. Whether this approach adequately captures arrhythmic burden, compared with longer-term continuous monitoring, is unclear. We sought to assess the long-term incidence of nonsustained ventricular tachycardia (NSVT) in HCM patients at low or moderate SCD risk, using implantable cardiac monitors (ICMs) paired with a novel Bluetooth-enabled 2-way communication platform. Methods: This prospective, single-arm, observational study enrolled 33 HCM patients. Patients were implanted with an Abbott (Chicago, IL) Confirm Rx ICM and monitored using a protocolized care pathway. Results: A total of 20 patients (60.6%) had ≥ 1 episode of NSVT recorded on the ICM, the majority of whom had previous Holter monitors that did not identify NSVT (60%, n = 12). A total of 71 episodes of NSVT were detected. Median time to first NSVT detection was 76.5 days (range: 0-553 days). A total of 19 patients underwent primary prevention implantable cardioverter defibrillator implantation during an average follow-up of 544 days (range: 42-925 days). A total of 172,112 automatic transmissions were received, and 65 (0.04%) required clinical follow-up. A total of 325 manual transmissions were received and managed. A total of 14 manual transmissions (4.3%) required follow-up, whereas 311 (95.7%) were managed solely with a text message. Conclusions: Surveillance and reporting systems utilizing 2-way communication enabled by novel ICMs are feasible and allow remote management of patients with HCM. Prolonged monitoring with ICMs identified more patients with nonsustained arrythmias than did standard Holter monitoring. In many cases, this information impacted both SCD risk stratification and patient management.


Contexte: La stratification du risque de mort cardiaque subite (MCS) dans la cardiomyopathie hypertrophique (CMH) dépend actuellement de la quantification de la charge arythmique par une surveillance Holter de 24 ou 48 heures. Il n'est pas clair si cette approche permet d'évaluer adéquatement la charge arythmique, comparativement à une surveillance continue à plus long terme. Nous avons cherché à évaluer la fréquence à long terme de la tachycardie ventriculaire non soutenue (TVNS) chez des patients atteints de CMH à risque faible ou modéré de MCS, au moyen de moniteurs cardiaques implantables (MCI) couplés à une nouvelle plate-forme de communication bidirectionnelle utilisable avec Bluetooth. Méthodologie: Cette étude par observation prospective comportant un seul groupe a été menée auprès de 33 patients atteints de CMH. Les patients ont reçu un MCI Confirm Rx d'Abbott (Chicago, États-Unis) et ont été surveillés dans le cadre d'un parcours de soins reposant sur un protocole. Résultats: Au total, 20 patients (60,6 %) ont eu au moins un épisode de TVNS enregistré par le MCI. La majorité de ces patients portaient déjà un moniteur Holter qui n'a pas décelé de TVNS (60 %, n = 12). Au total, 71 épisodes de TVNS ont été détectés. Le temps médian écoulé avant la première détection de TVNS était de 76,5 jours (fourchette : 0-553 jours). Au total, 19 patients se sont fait poser un défibrillateur cardioverteur implantable en prévention primaire pendant un suivi moyen de 544 jours (fourchette : 42-925 jours). En tout, 172 112 transmissions automatiques ont été reçues, et 65 (0,04 %) ont nécessité un suivi clinique. Par ailleurs, 325 transmissions manuelles ont été reçues et traitées. De ce nombre, 14 transmissions (4,3 %) ont nécessité un suivi, tandis que 311 (95,7 %) ont été traitées uniquement au moyen d'un message texte. Conclusions: Les systèmes de surveillance et de signalement utilisant une communication bidirectionnelle rendue possible grâce aux nouveaux MCI sont réalisables et permettent une prise en charge à distance des patients atteints d'un CMH. La surveillance prolongée par un MCI a permis de déceler plus d'arythmies non soutenues que la surveillance Holter type. Dans de nombreux cas, ces renseignements ont eu un effet positif tant sur la stratification du risque de MCS que sur la prise en charge des patients.

SELECTION OF CITATIONS
SEARCH DETAIL
...