Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Guang Pu Xue Yu Guang Pu Fen Xi ; 35(6): 1751-5, 2015 Jun.
Article in Chinese | MEDLINE | ID: mdl-26601403

ABSTRACT

As an important optical splitting element, grating is used in many different spectrometers and spectrographs. Spherical varied-line-spacing grating (SVLSG) is easily combined with array detectors to get a wide wavelength range of spectrums in one time, because it can focus the spectrums in approximately a plane. Therefore, it's widely used in many spectral instruments. We usually only know the central groove density of a commercial grating and its mounting parameters, while its line spacing parameters are unknown. Moreover, the mounting parameters are optimized within the whole using wavelength range of the grating. However, in most circumstances only part of the wavelength range is used. Therefore, the mounting parameters are not optimized for the needed wavelength range. Under this condition, in this article we developed a method based on the focusing theory of the flat-field grating and the mounting parameters the manufacture provided to deduce the line spacing parameters of the grating. With these parameters, we can optimize the detector position according to the wavelength range we need and ray tracing can be done to test the optical system. In this article we developed a high spectral resolution ultraviolet spectrograph, covering a wavelength range of 230-280 nm. The grating used in this spectrograph has a central groove density of 1 200 lines x mm(-1) and a designed wavelength range of 170-500 nm. We deduced the line spacing parameters of the grating and optimized the detector mounting parameters. Hollow cathode lamps of different elements were used to calibrate the spectrograph and test the spectral resolution of it. Wavelength calibration of the spectrograph has been done with the parameter fitting method, and the calibration accuracy is better than 0.01 nm. Results show the spectral resolution of the spectral graph is about 0.08 nm at 280.20 nm.

2.
Guang Pu Xue Yu Guang Pu Fen Xi ; 35(2): 304-8, 2015 Feb.
Article in Chinese | MEDLINE | ID: mdl-25970882

ABSTRACT

The present paper presents an auto-focus laser-induced breakdown spectroscopy (LIBS) remote measuring system. This system contains a Schwarzschild telescope, which consists of a convex mirror and a concave mirror. The two spherical mirrors are coaxially placed. The convex mirror is mounted on a motorized linear translation stage. With this motorized linear translation stage, the convex mirror can move along the optical axis to change the spacing between the convex mirror and the concave mirror. Therefore the focal length can be adjusted to focus the laser on samples at different distances and collect the plasma spectra. The advantages of the telescope system include, firstly, the light path of laser focusing and spectra signal collection is the same, which make it easier for mounting and collimation; secondly, the light path of the telescope uses total reflection type, which is fit for the detection in ultra-violate region; finally, the telescope consists of only two spherical mirrors which are relatively easier to manufacture. Within the translation range of the motorized linear translation stage, the focal length of the telescope in this paper can be adjusted from 1.5 to 3.6 m. The diameter of the focusing spot varies from 0.5 to 1.0 mm. Utilizing this telescope system, LIBS experiments were conducted using copper sample. And the characteristic lines of Cu element (Cu I 223.01 nm, Cu I 224.43 nm) obtained are used for the auto focusing. By investigating the relation of the area of spectral lines covered and the spacing between the mirrors, the optimal laser focusing location was obtained. The LIBS experiment results show that the system functions well, fulfilling the demand of remote ablation of sample and LIBS spectral measuring, and the telescope is able to auto-focus the laser on samples at different position to perform remote LIBS experiment.

SELECTION OF CITATIONS
SEARCH DETAIL
...