Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
1.
Article in Chinese | MEDLINE | ID: mdl-30141600

ABSTRACT

One hundred and sixty-three imported malaria cases were reported in Tai'an City of Shandong Province during 2011-2015, consisting of 120 cases of falciparum malaria(73.6%), 20 vivax malaria(12.3%), 14 ovale malaria(8.6%), 7 quartan malaria(4.3%), and 2 unclassified cases(1.2%). The disease onset showed no significant seasonal variation. The reported cases were more at the age of 40~49 years(70/163, 42.9%), and were imported mainly from Africa(156/163, 95.7%). The median interval from symptom onset to diagnosis was 4 days, and only 15 patients(9.2%) received definite diagnosis within 24 h. After medication, 161 cases recovered and 2 cases died.


Subject(s)
Malaria/epidemiology , China , Humans , Seasons
2.
Int J Clin Exp Med ; 8(3): 4581-5, 2015.
Article in English | MEDLINE | ID: mdl-26064388

ABSTRACT

OBJECTIVE: The present study aims to investigate the relationship between genetic polymorphisms in HTR3A and HTR3E and diarrhea predominant irritable bowel syndrome (D-IBS) in a Chinese population. METHODS: We enrolled 500 D-IBS patients and 500 age- and sex-matched healthy control subjects to detect the genotypes in HTR3A and HTR3B gene by using of PCR-RFLP method. RESULTS: There were significant difference between the D-IBS patients and the health control subjects in the distribution of genotype and allele of rs1062613 in HTR3A gene. As regarding rs62625044 in HTR3E gene, we found there was a significant different between the case and the control group in the distribution of GA genotype and A allele in female but not in male. CONCLUSION: The present study suggested that there are associations of D-IBS risk with genetic polymorphisms in HTR3A and HTR3E.

3.
J Biochem ; 155(1): 35-42, 2014 Jan.
Article in English | MEDLINE | ID: mdl-24394674

ABSTRACT

ATP-binding cassette transporter A1 (ABCA1) and CD36, type B scavenger receptor, function as the key mediators of macrophages cholesterol efflux and intake, respectively. However, their contribution to development of foam cells still remains uncertain. We here examined the effects of increased oxidized low-density lipoprotein (oxLDL) loading on the ABCA1 and CD36 expression, and lipid accumulation in THP-1 macrophages. The cultured THP-1 macrophages were treated with different copper-oxLDL concentrations. The intracellular lipid contents and cholesterol efflux were measured, and the ABCA1 and CD36 expression were assessed. We found that expression of ABCA1 and CD36 were coordinately induced upon low to moderate doses of oxLDL loading. However, higher doses of oxLDL stimulation resulted in the imbalanced expression of ABCA1 and CD36 proteins with more preferentially suppressed ABCA1 protein, attenuated cholesterol efflux and development of THP-1 derived foam cells. The PPAR-γ expression was remarkably induced, and PPAR-γ agonist, pioglitazone, significantly promoted the ABCA1 and CD36 expression. Additionally, ABCA1 and CD36 proteins were strong colocalized in THP-1 macrophages membrane. In conclusion, the more preferentially suppressed ABCA1 expression as compared with CD36 at higher doses of oxLDL stimulation may be the initiator for the formation of macrophage-derived foam cells.


Subject(s)
ATP Binding Cassette Transporter 1/metabolism , CD36 Antigens/metabolism , Foam Cells/metabolism , Lipoproteins, LDL/metabolism , Base Sequence , Cell Line , DNA Primers , Humans , PPAR gamma/metabolism , Real-Time Polymerase Chain Reaction
4.
Zhonghua Xin Xue Guan Bing Za Zhi ; 40(8): 662-6, 2012 Aug.
Article in Chinese | MEDLINE | ID: mdl-23141010

ABSTRACT

OBJECTIVE: To evaluate the platelet inhibition efficacy in patients under regular maintenance dose of clopidogrel by VerifyNow-P2Y12 assay and explore the clinical characteristics of clopidogrel non-responders and related predicting factors. METHODS: A total of 99 patients underwent percutaneous coronary intervention procedure and receiving clopidogrel in regular maintenance dose for at least 1 week were enrolled. Platelet reactivity, including baseline, P2Y12 reaction unit (PRU), and platelet inhibition rate were measured with VeifyNow-P2Y12 assay. The dosage of anti-platelet drugs, combination with any other drugs, clinical characters in baseline of all enrolled patients were analyzed. PRU ≤ 240 was used as cut-off to identify clopidogrel responder and clopidogrel non-responder. In the non-responder group, patients were further separated into 3 sub-groups (types) according to the baseline and platelet inhibition rate: type I with high baseline, high inhibition rate, representing false non-responder; type II with low inhibition rate, representing true non-responder and type III mixed type. RESULTS: In this study, 48 of 99 patients were found to be clopidogrel non-responder (48.5%). The ratio of type I, type II and type III in the non-responder group was 9.1% (n = 9), 27.3% (n = 27), and 12.1% (n = 12), respectively. Baseline platelet value in female patients was significantly higher than in males (P < 0.01), number of females with high PRU also is higher than males (P < 0.01), female gender was a predict factor for type I non-responder (OR = 6.5, 95%CI 2.295 - 18.407, P < 0.01). BMI > 24 kg/m(2) was a risk factor for clopidogrel non-responder (P < 0.05), and may be regarded as a predict factor for type II non-responder (OR = 3.207, 95%CI 1.375 - 7.485, P < 0.01). Age, hypertension, diabetics, smoking, hyperlipidemia, CRP and pantoprazole use do not show significant correlation with baseline and platelet inhibition rate. CONCLUSIONS: Clopidogrel responses could be reliably detected by VerifyNow-P2Y12 assay. Female gender and high body weight are independent risk factors for clopidogrel non-responses.


Subject(s)
Angioplasty, Balloon, Coronary , Platelet Aggregation Inhibitors/pharmacology , Receptors, Purinergic P2Y12 , Ticlopidine/analogs & derivatives , Aged , Clopidogrel , Female , Humans , Male , Middle Aged , Platelet Aggregation/drug effects , Platelet Function Tests , Ticlopidine/pharmacology
5.
Zhonghua Xin Xue Guan Bing Za Zhi ; 40(6): 487-91, 2012 Jun.
Article in Chinese | MEDLINE | ID: mdl-22943643

ABSTRACT

OBJECTIVE: To evaluate the diagnostic accuracy of 320-slice CT coronary angiography (CTA) in the evaluation of in-stent restenosis (ISR, ≥50% luminal narrowing) in comparison with quantitative coronary angiography (CAG). METHODS: A total of 69 patients with previous stent implantation who underwent both CTA and CAG were prospectively included. We assessed diagnostic valve for ISR with CTA in comparison with CAG. RESULTS: A total of 110 stents were implanted in these patients.CAG identified 14 ISR. CTA correctly identified 13 ISR and misdiagnosed 5 ISR in stents without ISR. Besides, 6 stents could not be evaluated by CTA due to unsatisfied image quality. Accordingly, sensitivity, specificity, positive and negative predictive value of CTA for diagnosing ISR were 93%, 89%, 54% and 99%, respectively. The image quality of CTA was significantly better in larger stents (percentages of good and moderate stent image of ≥3.0 mm and <3.0 mm: 56% vs. 27%, 25% vs. 49%) and which was linked with better diagnostic coincidence rate (95% vs. 78%) for larger stents. The image quality of CTA was significantly better in stents with thinner stent strut thickness (percentages of poor CTA stent image quality of stent strut thickness<140 µm and ≥140 µm: 12% vs. 45%, P<0.01) and which was associated with better diagnostic coincidence rate for stents with thinner stent strut thickness (94% vs. 76%, P<0.05). The image quality of CTA was also significantly better in single stent (percentages of poor CTA stent image quality of single stent vs. overlap and dedicated stent: 17% vs. 36%, P<0.05). However, heart rate (≥65 beats/min vs. <65 beats/min) during CTA acquisition was not associated with image quality and the diagnostic coincidence rate (all P>0.05). CONCLUSIONS: Our results indicate that 320-slice CTA allows accurate noninvasive assessment of significant in-stent restenosis in selected patients. Stents with a large diameter and thin struts are associated with better image quality and higher diagnostic accuracy.


Subject(s)
Coronary Restenosis/diagnostic imaging , Tomography, X-Ray Computed/methods , Aged , Aged, 80 and over , Coronary Angiography , Female , Humans , Male , Middle Aged , Predictive Value of Tests , Prospective Studies , Sensitivity and Specificity , Stents
SELECTION OF CITATIONS
SEARCH DETAIL
...