ABSTRACT

While testing 414 sera for the diagnosis of Chagas' disease, the conventional reactions of indirect hemagglutination, indirect immunofluorescence and the immunosorbent assay showed a sensitivity of 95.7%, 100% and 98.2% and a specificity of 98%, 98% and 96.4%, respectively, and an excellent association using Fisher's exact test. Chemiluminescence presented 100% sensitivity and 89.6% specificity, while PCR showed 100% specificity and 1.2% sensitivity. It is believed that the three conventional serological reactions are still adequate for diagnosing Chagas' disease.


Subject(s)
Chagas Disease/diagnosis , Polymerase Chain Reaction , Serologic Tests/methods , Adolescent , Adult , Aged , Aged, 80 and over , Animals , Child , Enzyme-Linked Immunosorbent Assay , Female , Fluorescent Antibody Technique, Indirect , Hemagglutination Tests , Humans , Luminescent Measurements , Male , Middle Aged , Reproducibility of Results , Sensitivity and Specificity , Trypanosoma cruzi/genetics , Trypanosoma cruzi/immunology
2.
Rev. Soc. Bras. Med. Trop ; 39(4): 385-387, jul.-ago. 2006. tab
Article in English | LILACS | ID: lil-439885

ABSTRACT

While testing 414 sera for the diagnosis of Chagas' disease, the conventional reactions of indirect hemagglutination, indirect immunofluorescence and the immunosorbent assay showed a sensitivity of 95.7 percent, 100 percent and 98.2 percent and a specificity of 98 percent, 98 percent and 96.4 percent, respectively, and an excellent association using Fisher's exact test. Chemiluminescence presented 100 percent sensitivity and 89.6 percent specificity, while PCR showed 100 percent specificity and 1.2 percent sensitivity. It is believed that the three conventional serological reactions are still adequate for diagnosing Chagas' disease.


No exame de 414 soros, para o diagnóstico da doença de Chagas, as reações convencionais de hemaglutinação indireta, imunofluorescência indireta e o ensaio imunoenzimático mostraram, respectivamente, uma sensibilidade de 95,7 por cento, 100 por cento e 98,2 por cento e uma especificidade de 98 por cento, 98 por cento e 96,4 por cento e excelente associação usando teste exato de Fisher. A quimioluminescência apresentou 100 por cento de sensibilidade, 89,6 por cento de especificidade e a PCR 100 por cento de especificidade e 1,2 por cento de sensibilidade. Acredita-se que as três reações sorológicas convencionais ainda são suficientes para o diagnóstico da doença de Chagas.


Subject(s)
Humans , Animals , Male , Female , Child , Adolescent , Adult , Middle Aged , Aged, 80 and over , Chagas Disease/diagnosis , Luminescent Measurements , Polymerase Chain Reaction , Serologic Tests/methods , Enzyme-Linked Immunosorbent Assay , Fluorescent Antibody Technique, Indirect , Hemagglutination Tests , Reproducibility of Results , Sensitivity and Specificity , Trypanosoma cruzi/genetics , Trypanosoma cruzi/immunology
SELECTION OF CITATIONS