1.
Lancet Oncol ; 2024 Jul 16.
Article in English | MEDLINE | ID: mdl-39029483

ABSTRACT

BACKGROUND: Refractory upper abdominal pain or lower back pain (retroperitoneal pain syndrome) related to celiac plexus involvement characterises pancreatic and other upper gastrointestinal malignancies and is an unmet need. We hypothesised that ablative radiation delivered to the celiac plexus would decrease pain. METHODS: This multicentre, single-arm, phase 2 study was done at eight hospitals in five countries (Israel, Poland, Canada, the USA, and Portugal). Eligible patients aged 18 years or older with an average pain level of 5-10 on the Brief Pain Inventory short form (BPI-SF), an Eastern Cooperative Oncology Group performance status score of 0-2, and either pancreatic cancer or other tumours involving the celiac axis, received a single fraction of 25 Gy of external-beam photons to the celiac plexus. The primary endpoint was complete or partial pain response based on a reduction of the BPI-SF average pain score of 2 points or more from baseline to 3 weeks after treatment. All evaluable patients with stable pain scores were included in response assessment. The trial is registered with ClinicalTrials.gov, NCT03323489, and is complete. FINDINGS: Between Jan 3, 2018, and Dec 28, 2021, 125 patients were treated, 90 of whom were evaluable. Patients were followed up until death. Median age was 65·5 years (IQR 58·3-71·8), 50 (56%) were female and 40 (44%) were male, 83 (92%) had pancreatic cancer, and 77 (86%) had metastatic disease. Median baseline BPI-SF average pain score was 6 (IQR 5-7). Of the 90 evaluable patients at 3 weeks, 48 (53%; 95% CI 42-64) had at least a partial pain response. The most common grade 3-4 adverse events, irrespective of attribution, were abdominal pain (35 [28%] of 125) and fatigue (23 [18%]). 11 serious adverse events of grade 3 or worse were recorded. Two grade 3 serious adverse events were probably attributed to treatment by the local investigators (abdominal pain [n=1] and nausea [n=1]), and nine were possibly attributed to treatment (seven were grade 3: blood bilirubin increased [n=1], duodenal haemorrhage [n=2], abdominal pain [n=2], and progressive disease [n=2]; and two were grade 5: gastrointestinal bleed from suspected varices 24 days after treatment [n=1] and progressive disease [advanced pancreatic cancer] 89 days after treatment [n=1]). INTERPRETATION: Celiac plexus radiosurgery could potentially be a non-invasive palliative option for patients with retroperitoneal pain syndrome. Further investigation by means of a randomised comparison with conventional celiac block or neurolysis is warranted. FUNDING: Gateway for Cancer Research and the Israel Cancer Association.

2.
Radiat Prot Dosimetry ; 199(15-16): 1829-1833, 2023 Oct 11.
Article in English | MEDLINE | ID: mdl-37819352

ABSTRACT

Response of personal dosemeters to high energy photon radiation is of great interest nowadays due to a spread of new radiation technologies and the expansion of occupational exposure domains. ICRU95 publication has expanded the range of relevant photon energies upwards, setting new horizons for individual monitoring. Beryllium oxide (BeO) material is increasingly popular due to its excellent optically stimulated luminescence (OSL) properties, simple readout and reasonable energy response in the low energy (below 100 keV) range. The study considers energy dependence of OSL response at higher photon energies. Energy deposition of monoenergetic photons with energy up to 15 MeV in the BeO chips of various thickness was modeled with Monte Carlo MCNP 6.2 code. Benchmark experiments were conducted at LINAC with high voltage of 6, 10 and 15 MV resulting in respective incident photon spectra. The findings of this study add knowledge regarding behavior of BeO personal dosemeters in the photon fields within the energy range above 3 MeV.


Subject(s)
Luminescence , Photons , Radiotherapy, High-Energy , Monte Carlo Method
3.
Br J Radiol ; 92(1097): 20180960, 2019 May.
Article in English | MEDLINE | ID: mdl-30864828

ABSTRACT

OBJECTIVE: Intensity-modulated radiotherapy (IMRT) has better normal-tissue sparing compared with 3-dimensional conformal radiation (3DCRT). We sought to assess the impact of radiation technique on pathological and clinical outcomes in locally advanced non-small cell lung cancer (LANSCLC) treated with a trimodality strategy. METHODS: Retrospective review of LANSCLC patients treated from August 2012 to August 2018 at Sheba Medical Center, Israel. The trimodality strategy consisted of concomitant chemoradiation to 60 Gray (Gy) followed by completion surgery. The planning target volume (PTV) was defined by co-registered PET/CT. Here we compare the pathological regression, surgical margin status, local control rates (LC), disease free (DFS) and overall survival (OS) between 3DCRT and IMRT. RESULTS: Our cohort consisted of 74 patients with mean age 62.9 years, male in 51/74 (69%), adenocarcinoma in 46/74 (62.1%), stage 3 in 59/74 (79.7%) and chemotherapy in 72/74 (97.3%). Radiation mean dose: 59.2 Gy (SD ± 3.8). Radiation technique : 3DCRT in 51/74 (68.9%), IMRT in 23/74 (31%). Other variables were similar between groups.Major pathological response (including pathological complete response or less than 10% residual tumor cells) was similar: 32/51 (62.7%) in 3DCRT and 15/23 (65.2%) in IMRT, p=0.83. Pathological complete response (pCR) rates were similar: 17/51 (33.3%) in 3DCRT and 8/23 (34.8%) in IMRT, p=0.9. Surgical margins were negative in 46/51 (90.1%) in 3DCRT vs. 17/19 (89.4%) in IMRT (p=1.0).The 2-year LC rates were 81.6% (95% CI 69-89.4%); DFS 58.3% (95% CI 45.5-69%) and 3-year OS 70% (95% CI57-80%). Comparing radiation techniques, there were no significant differences in LC (p=0.94), DFS (p=0.33) and OS (p=0.72). CONCLUSION: When used to treat LANSCLC in the neoadjuvant setting, both IMRT and 3DCRT produce comparable pathological and clinical outcomes. ADVANCES IN KNOWLEDGE: This study validates the real-world effectiveness of IMRT compared to 3DCRT.


Subject(s)
Carcinoma, Non-Small-Cell Lung/radiotherapy , Lung Neoplasms/radiotherapy , Radiotherapy, Conformal , Radiotherapy, Intensity-Modulated , Aged , Carcinoma, Non-Small-Cell Lung/pathology , Carcinoma, Non-Small-Cell Lung/surgery , Chemoradiotherapy , Comparative Effectiveness Research , Disease-Free Survival , Female , Humans , Lung Neoplasms/pathology , Lung Neoplasms/surgery , Male , Middle Aged , Neoadjuvant Therapy , Neoplasm Staging , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted , Radiotherapy, Adjuvant , Radiotherapy, Conformal/adverse effects , Radiotherapy, Conformal/methods , Radiotherapy, Intensity-Modulated/adverse effects , Radiotherapy, Intensity-Modulated/methods , Retrospective Studies , Survival Analysis , Tumor Burden
4.
Int J Radiat Oncol Biol Phys ; 93(2): 391-9, 2015 Oct 01.
Article in English | MEDLINE | ID: mdl-26264628

ABSTRACT

OBJECTIVE: To determine the effect of continuous positive airway pressure (CPAP) on tumor motion, lung volume, and dose to critical organs in patients receiving stereotactic body radiation therapy (SBRT) for lung tumors. METHODS AND MATERIALS: After institutional review board approval in December 2013, patients with primary or secondary lung tumors referred for SBRT underwent 4-dimensional computed tomographic simulation twice: with free breathing and with CPAP. Tumor excursion was calculated by subtracting the vector of the greatest dimension of the gross tumor volume (GTV) from the internal target volume (ITV). Volumetric and dosimetric determinations were compared with the Wilcoxon signed-rank test. CPAP was used during treatment if judged beneficial. RESULTS: CPAP was tolerated well in 10 of the 11 patients enrolled. Ten patients with 18 lesions were evaluated. The use of CPAP decreased tumor excursion by 0.5 ± 0.8 cm, 0.4 ± 0.7 cm, and 0.6 ± 0.8 cm in the superior-inferior, right-left, and anterior-posterior planes, respectively (P ≤ .02). Relative to free breathing, the mean ITV reduction was 27% (95% confidence interval [CI] 16%-39%, P<.001). CPAP significantly augmented lung volume, with a mean absolute increase of 915 ± 432 cm(3) and a relative increase of 32% (95% CI 21%-42%, P=.003), contributing to a 22% relative reduction (95% CI 13%-32%, P=.001) in mean lung dose. The use of CPAP was also associated with a relative reduction in mean heart dose by 29% (95% CI 23%-36%, P=.001). CONCLUSION: In this pilot study, CPAP significantly reduced lung tumor motion compared with free breathing. The smaller ITV, the planning target volume (PTV), and the increase in total lung volume associated with CPAP contributed to a reduction in lung and heart dose. CPAP was well tolerated, reproducible, and simple to implement in the treatment room and should be evaluated further as a novel strategy for motion management in radiation therapy.


Subject(s)
Continuous Positive Airway Pressure , Lung Neoplasms/surgery , Movement , Radiosurgery/methods , Respiration , Adult , Aged , Confidence Intervals , Feasibility Studies , Female , Four-Dimensional Computed Tomography , Humans , Lung Neoplasms/diagnostic imaging , Male , Middle Aged , Pilot Projects , Radiotherapy Planning, Computer-Assisted/methods , Statistics, Nonparametric
SELECTION OF CITATIONS
SEARCH DETAIL
...