1.
J Synchrotron Radiat ; 26(Pt 4): 1374-1387, 2019 Jul 01.
Article in English | MEDLINE | ID: mdl-31274467

ABSTRACT

A new high-vacuum multipurpose diffractometer (called FORTE from the French acronyms of the project) has recently been installed at the tender/hard X-ray SIRIUS beamline of Synchrotron SOLEIL, France. The geometry chosen allows one to work either in the classical Eulerian four-circle geometry for bulk X-ray diffraction (XRD) or in the z-axis geometry for surface XRD. The diffractometer nicely fits the characteristics of the SIRIUS beamline, optimized to work in the 1.1-4.5 keV range, and allows one to perform unprecedented diffraction anomalous fine structure (DAFS) experiments in the tender X-ray region, also around non-specular reflections, covering a large reciprocal-space volume. Installation of an X-ray fluorescence detector on a dedicated flange allows simultaneous DAFS and X-ray absorption (XAS) measurements. The access to the tender X-ray region paves the way to resonant investigations around the L-edges of second-row transition elements which are constituents of functional oxide materials. It also enables access to several edges of interest for semiconductors. Finally, the control architecture based on synchronized Delta Tau units opens up exciting perspectives for improvement of the mechanical sphere of confusion.

2.
J Synchrotron Radiat ; 5(Pt 3): 992-4, 1998 May 01.
Article in English | MEDLINE | ID: mdl-15263722

ABSTRACT

This paper reports on two new technical developments concerning sample environments for X-ray magnetic circular dichroism (XMCD). The first measurements under high pressures of up to 30 GPa are described. The difficulties of combining the techniques of high pressure and XMCD are commented on. The second development involves the use of a fast-switching magnetic field. A new superconducting device is used to perform XMCD measurements on paramagnetic compounds in magnetic fields of up to 6 T. The small amplitude of the XMCD signal imposes, for a given signal-to-noise ratio, a noise less than a few 10(-5). The signal-to-noise ratio is improved by the use of a series of acquisitions, switching the magnetic field between each acquisition. A very fast switching mechanism has been built based on mechanical rotation of a superconducting coil, with the sample kept in place inside the coil. The XMCD signals at the L(II,III)-edges of paramagnetic rare-earth compounds have been measured at 4.5 K in fields of up to 6 T with a switching time of 11 s.

SELECTION OF CITATIONS
SEARCH DETAIL
...