Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Pacing Clin Electrophysiol ; 35(4): 392-402, 2012 Apr.
Article in English | MEDLINE | ID: mdl-22309303

ABSTRACT

AIMS: SafeR performance versus DDD/automatic mode conversion (DDD/AMC) and DDD with a 250-ms atrioventricular (AV) delay (DDD/LD) modes was assessed toward ventricular pacing (Vp) reduction. METHODS: After a 1-month run-in phase, recipients of dual-chamber pacemakers without persistent AV block and persistent atrial fibrillation (AF) were randomly assigned to SafeR, DDD/AMC, or DDD/LD in a 1:1:1 design. The main endpoint was the percentage of Vp (%Vp) at 2 months and 1 year after randomization, ascertained from device memories. Secondary endpoints include %Vp at 1 year according to pacing indication and 1-year AF incidence based on automatic mode switch device stored episodes. RESULTS: Among 422 randomized patients (73.2±10.6 years, 50% men, sinus node dysfunction 47.4%, paroxysmal AV block 30.3%, bradycardia-tachycardia syndrome 21.8%), 141 were assigned to SafeR versus 146 to DDD/AMC and 135 to DDD/LD modes. Mean %Vp at 2 months was 3.4±12.6% in SafeR versus 33.6±34.7% and 14.0±26.0% in DDD/AMC and DDD/LD modes, respectively (P<0.0001 for both). At 1 year, mean %Vp in SafeR was 4.5±15.3% versus 37.9±34.4% and 16.7±28.0% in DDD/AMC and DDD/LD modes, respectively (P<0.0001 for both). The proportion of patients in whom Vp was completely eliminated was significantly higher in SafeR (69%) versus DDD/AMC (15%) and DDD/LD (45%) modes (P<0.0001 for both), regardless of pacing indication. The absolute risk of developing permanent AF or of remaining in AF for >30% of the time was 5.4% lower in SafeR than in the DDD pacing group (ns). CONCLUSIONS: In this selected patient population, SafeR markedly suppressed unnecessary Vp compared with DDD modes.


Subject(s)
Atrial Fibrillation/therapy , Cardiac Pacing, Artificial/methods , Pacemaker, Artificial , Aged , Aged, 80 and over , Atrioventricular Block/therapy , Bradycardia/therapy , Female , Humans , Male , Middle Aged , Sick Sinus Syndrome/therapy , Syndrome , Tachycardia/therapy , Treatment Outcome
2.
Europace ; 8(2): 96-101, 2006 Feb.
Article in English | MEDLINE | ID: mdl-16627417

ABSTRACT

AIMS: To examine the performance of AAIsafeR2, a new pacing mode to minimize the cumulative proportion of ventricular pacing in patients who do not need regular ventricular support. METHODS AND RESULTS: The safety of AAIsafeR2 was examined in 123 recipients (73 +/- 12 years old, 51% men) of dual chamber pacemakers implanted for sinus node dysfunction, paroxysmal AV block or the bradycardia-tachycardia syndrome. Data were collected from pacemaker diagnostics, and the first 43 patients underwent 24-h Holter recordings before being discharged from the hospital with AAIsafeR2 activated. No adverse event related to AAIsafeR2 was observed. All ventricular pauses detected on Holter tapes triggered immediate back-up ventricular pacing. Appropriate switches to DDD occurred in 97 of 123 patients. In 69 of 123 devices (56%) switches to DDD were non-sustained, and the average % ventricular pacing in this group was 0.2+/-0.5%. CONCLUSION: AAIsafeR2 mode seems to be safe and reliable in patients with infrequent slowing or pauses in ventricular activity, while maintaining ventricular pacing below 1%.


Subject(s)
Arrhythmias, Cardiac/therapy , Cardiac Pacing, Artificial/methods , Pacemaker, Artificial , Aged , Aged, 80 and over , Cardiac Pacing, Artificial/adverse effects , Electrocardiography, Ambulatory , Equipment Safety , Female , Follow-Up Studies , Heart Atria/physiopathology , Heart Ventricles/physiopathology , Humans , Male , Middle Aged , Sinoatrial Node/physiopathology , Syndrome , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...