Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
J Appl Clin Med Phys ; 25(4): e14309, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38386922

ABSTRACT

OBJECTIVE: This study identifies key characteristics to help build a physical liver computed tomography (CT) phantom for radiomics harmonization; particularly, the higher-order texture metrics. MATERIALS AND METHODS: CT scans of a radiomics phantom comprising of 18 novel 3D printed inserts with varying size, shape, and material combinations were acquired on a 64-slice CT scanner (Brilliance 64, Philips Healthcare). The images were acquired at 120 kV, 250 mAs, CTDIvol of 16.36 mGy, 2 mm slice thickness, and iterative noise-reduction reconstruction (iDose, Philips Healthcare, Andover, MA). Radiomics analysis was performed using the Cancer Imaging Phenomics Toolkit (CaPTk), following automated segmentation of 3D regions of interest (ROI) of the 18 inserts. The findings were compared to three additional ROI obtained of an anthropomorphic liver phantom, a patient liver CT scan, and a water phantom, at comparable imaging settings. Percentage difference in radiomic metrics values between phantom and tissue was used to assess the biological equivalency and <10% was used to claim equivalent. RESULTS: The HU for all 18 ROI from the phantom ranged from -30 to 120 which is within clinically observed HU range of the liver, showing that our phantom material (T3-6B) is representative of biological CT tissue densities (liver) with >50% radiomic features having <10% difference from liver tissue. Based on the assessment of the Neighborhood Gray Tone Difference Matrix (NGTDM) metrics it is evident that the water phantom ROI show extreme values compared to the ROIs from the phantom. This result may further reinforce the difference between a structureless quantity such as water HU values and tissue HU values found in liver. CONCLUSION: The 3-D printed patterns of the constructed radiomics phantom cover a wide span of liver tissue textures seen in CT images. Using our results, texture metrics can be selectively harmonized to establish clinically relevant and reliable radiomics panels.


Subject(s)
Radiomics , Tomography, X-Ray Computed , Humans , Tomography, X-Ray Computed/methods , Tomography Scanners, X-Ray Computed , Phantoms, Imaging , Liver/diagnostic imaging , Water , Image Processing, Computer-Assisted/methods
2.
J Appl Clin Med Phys ; 25(4): e14192, 2024 Apr.
Article in English | MEDLINE | ID: mdl-37962032

ABSTRACT

OBJECTIVE: This study assesses the robustness of first-order radiomic texture features namely interquartile range (IQR), coefficient of variation (CV) and standard deviation (SD) derived from computed tomography (CT) images by varying dose, reconstruction algorithms and slice thickness using scans of a uniform water phantom, a commercial anthropomorphic liver phantom, and a human liver in-vivo. MATERIALS AND METHODS: Scans were acquired on a 16 cm detector GE Revolution Apex Edition CT scanner with variations across three different nominal slice thicknesses: 0.625, 1.25, and 2.5 mm, three different dose levels: CTDIvol of 13.86 mGy for the standard dose, 40% reduced dose and 60% reduced dose and two different reconstruction algorithms: a deep learning image reconstruction (DLIR-high) algorithm and a hybrid iterative reconstruction (IR) algorithm ASiR-V50% (AV50) were explored, varying one at a time. To assess the effect of non-linear modifications of images by AV50 and DLIR-high, images of the water phantom were also reconstructed using filtered back projection (FBP). Quantitative measures of IQR, CV and SD were extracted from twelve pre-selected, circular (1 cm diameter) regions of interest (ROIs) capturing different texture patterns across all scans. RESULTS: Across all scans, imaging, and reconstruction settings, CV, IQR and SD were observed to increase with reduction in dose and slice thickness. An exception to this observation was found when using FBP reconstruction. Lower values of CV, IQR and SD were observed in DLIR-high reconstructions compared to AV50 and FBP. The Poisson statistics were more stringently noted in FBP than DLIR-high and AV50, due to the non-linear nature of the latter two algorithms. CONCLUSION: Variation in image noise due to dose reduction algorithms, tube current, and slice thickness show a consistent trend across phantom and patient scans. Prospective evaluation across multiple centers, scanners and imaging protocols is needed for establishing quality assurance standards of radiomics.


Subject(s)
Algorithms , Tomography, X-Ray Computed , Humans , Radiation Dosage , Tomography, X-Ray Computed/methods , Phantoms, Imaging , Water , Radiographic Image Interpretation, Computer-Assisted/methods , Image Processing, Computer-Assisted/methods
3.
Br J Radiol ; 95(1137): 20211211, 2022 Sep 01.
Article in English | MEDLINE | ID: mdl-35671097

ABSTRACT

OBJECTIVE: To perform a systematic assessment and analyze the quality of radiomics methodology in current literature in the evaluation of renal masses using the Radiomics Quality Score (RQS) approach. METHODS: We systematically reviewed recent radiomics literature in renal masses published in PubMed, EMBASE, Elsevier, and Web of Science. Two reviewers blinded by each other's scores evaluated the quality of radiomics methodology in studies published from 2015 to August 2021 using the RQS approach. Owing to the diversity in the imaging modalities and radiomics applications, a meta-analysis could not be performed. RESULTS: Based on our inclusion/exclusion criteria, a total of 87 published studies were included in our study. The highest RQS was noted in three categories: reporting of clinical utility, gold standard, and feature reduction. The average RQS of the two reviewers ranged from 5 ≤ RQS≤19, with the maximum attainable RQS being 36. Very few (7/87 i.e., 8%) studies received an average RQS that ranged from 17 < RQS≤19, which represents studies with the highest RQS in our study. Many (39/87 i.e., 45%) studies received an average RQS that ranged from 13 < RQS≤15. No significant interreviewer scoring differences were observed. CONCLUSIONS: We report that the overall scientific quality and reporting of radiomics studies in renal masses is suboptimal, and subsequent studies should bolster current deficiencies to improve reporting of radiomics methodologies. ADVANCES IN KNOWLEDGE: The RQS approach is a meaningful quantitative scoring system to assess radiomics methodology quality and supports a comprehensive evaluation of the radiomics approach before its incorporation into clinical practice.

SELECTION OF CITATIONS
SEARCH DETAIL
...