Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Front Bioeng Biotechnol ; 11: 1190879, 2023.
Article in English | MEDLINE | ID: mdl-37274159

ABSTRACT

Chito-oligosaccharides (COS), derived from chitosan (CH), are attracting increasing attention as drug delivery carriers due to their biocompatibility, biodegradability, and mucoadhesive properties. Grafting, the process of chemically modifying CH/COS by adding side chains, has been used to improve their drug delivery performance by enhancing their stability, targeted delivery, and controlled release. In this review, we aim to provide an in-depth study on the recent advances in the grafting of CH/COS for multifarious applications. Moreover, the various strategies and techniques used for grafting, including chemical modification, enzymatic modification, and physical modification, are elaborated. The properties of grafted CH/COS, such as stability, solubility, and biocompatibility, were reported. Additionally, the review detailed the various applications of grafted CH/COS in drug delivery, including the delivery of small drug molecule, proteins, and RNA interference therapeutics. Furthermore, the effectiveness of grafted CH/COS in improving the pharmacokinetics and pharmacodynamics of drugs was included. Finally, the challenges and limitations associated with the use of grafted CH/COS for drug delivery and outline directions for future research are addressed. The insights provided in this review will be valuable for researchers and drug development professionals interested in the application of grafted CH/COS for multifarious applications.

2.
Article in English | MEDLINE | ID: mdl-25240204

ABSTRACT

The present study describes a novel liquid chromatographic-tandem mass spectrometric (LC-MS/MS) method for the simultaneous estimation of ramipril (RAM) and hydrochlorothiazide (HCTZ) in human plasma using liquid-liquid extraction technique. This method made use of electrospray ionization in positive mode for RAM and in negative mode for HCTZ using triple quadrupole mass spectrometry where carbamazepine was used as an internal standard (IS). Analytes were recovered by methyl tertiary butyl ether:dichloromethane (85:15) subsequently separated on an Enable C18 G column (150 mm × 4.6 mm, 5 µm) using methanol:0.1% formic acid in water (85:15) as a mobile phase, at a flow rate of 0.5 mL/min. Quantification of RAM, HCTZ and IS was performed using multi-reaction monitoring mode (MRM) where transition of m/z 417.2→234.1 (RAM) and 237.0→194.0 (IS) in positive mode and 296.1→205.0 for HCTZ in negative mode. The calibration curve was linear (r(2)>0.99) over the concentration range of 2-170 ng/mL for RAM and 8-680 ng/mL for HCTZ. The intra-day and inter-day precisions were <15% and the accuracy was all within ±15% (at LLOQ level ±20%). Additionally, the LC-MS/MS method was fully validated for all the other parameters such as selectivity, matrix effect, recovery and stability as well. In conclusion, the findings of the present study revealed the selectivity and sensitivity of this method for the simultaneous estimation of RAM and HCTZ in human plasma.


Subject(s)
Chromatography, Liquid/methods , Hydrochlorothiazide/blood , Ramipril/blood , Tandem Mass Spectrometry/methods , Drug Stability , Humans , Hydrochlorothiazide/chemistry , Linear Models , Ramipril/chemistry , Reproducibility of Results , Sensitivity and Specificity
SELECTION OF CITATIONS
SEARCH DETAIL
...